2021年德国心肌灌注SPECT和ATTR成像:第九次调查结果。

IF 1 4区 医学 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Nuklearmedizin-nuclear Medicine Pub Date : 2023-08-01 DOI:10.1055/a-2084-7454
Oliver Lindner, Wolfgang Michael Schaefer, Sigmund Silber, Christoph Rischpler, Wolfgang Burchert
{"title":"2021年德国心肌灌注SPECT和ATTR成像:第九次调查结果。","authors":"Oliver Lindner,&nbsp;Wolfgang Michael Schaefer,&nbsp;Sigmund Silber,&nbsp;Christoph Rischpler,&nbsp;Wolfgang Burchert","doi":"10.1055/a-2084-7454","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>This paper presents the results of the 9th survey of myocardial perfusion SPECT (MPS) from the reporting year 2021.</p><p><strong>Methods: </strong>218 questionnaires (131 practices (PR), 58 hospitals (HO), 29 university hospitals (UH)) were evaluated. Results of the last survey 2018 are set in squared brackets.</p><p><strong>Results: </strong>MPS data from a total of 133,057 [145,930] patients (-8.8%) with 131,868 [143,707] stress and 106,546 [121,899] rest MPS were analysed. A comparison with official data revealed that 54% all MPS were recorded. From 2018 to 2021, official data showed a every year an increase in MPS numbers. On average, 610 [502] MPS patients (+22%) were examined in each department. 74% [69%] of the responders reported an increase or no changes in their MPS patient numbers. Ambulatory care cardiologists represented as always, the mayor referral group (68% [69%]). For the first time, pharmacological stress was more frequently applied than ergometry (42% [51]). Regadenoson was mostly used. The use of the different protocols remained nearly unchanged. Two-day protocols were predominantly applied (49% [48%]). A shift from multi-headed cameras (58% [72%]) to SPECT-CT systems (24% [17%]) was found. Attenuation correction was performed in 33% [26%] of all MPS. 88% [86%] of all stress, 88% [87%] of all rest and 87% [83%] of all stress and rest MPS were acquired as gated SPECT. 72% [67%] of all departments performed scoring by default. The number of departments without scoring decreased to 13% [16%].</p><p><strong>Conclusions: </strong>The MPS Study 2021 shows that the long-term positive development of MPS imaging in Germany is continuing. The COVID-19 pandemia did not change this trend. The procedural and technical details of MPS imaging reveal a high level of guideline conformity.</p>","PeriodicalId":19238,"journal":{"name":"Nuklearmedizin-nuclear Medicine","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/6d/ff/10-1055-a-2084-7454.PMC10477021.pdf","citationCount":"1","resultStr":"{\"title\":\"Myocardial Perfusion SPECT and ATTR imaging 2021 in Germany: Results of the 9th Survey.\",\"authors\":\"Oliver Lindner,&nbsp;Wolfgang Michael Schaefer,&nbsp;Sigmund Silber,&nbsp;Christoph Rischpler,&nbsp;Wolfgang Burchert\",\"doi\":\"10.1055/a-2084-7454\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>This paper presents the results of the 9th survey of myocardial perfusion SPECT (MPS) from the reporting year 2021.</p><p><strong>Methods: </strong>218 questionnaires (131 practices (PR), 58 hospitals (HO), 29 university hospitals (UH)) were evaluated. Results of the last survey 2018 are set in squared brackets.</p><p><strong>Results: </strong>MPS data from a total of 133,057 [145,930] patients (-8.8%) with 131,868 [143,707] stress and 106,546 [121,899] rest MPS were analysed. A comparison with official data revealed that 54% all MPS were recorded. From 2018 to 2021, official data showed a every year an increase in MPS numbers. On average, 610 [502] MPS patients (+22%) were examined in each department. 74% [69%] of the responders reported an increase or no changes in their MPS patient numbers. Ambulatory care cardiologists represented as always, the mayor referral group (68% [69%]). For the first time, pharmacological stress was more frequently applied than ergometry (42% [51]). Regadenoson was mostly used. The use of the different protocols remained nearly unchanged. Two-day protocols were predominantly applied (49% [48%]). A shift from multi-headed cameras (58% [72%]) to SPECT-CT systems (24% [17%]) was found. Attenuation correction was performed in 33% [26%] of all MPS. 88% [86%] of all stress, 88% [87%] of all rest and 87% [83%] of all stress and rest MPS were acquired as gated SPECT. 72% [67%] of all departments performed scoring by default. The number of departments without scoring decreased to 13% [16%].</p><p><strong>Conclusions: </strong>The MPS Study 2021 shows that the long-term positive development of MPS imaging in Germany is continuing. The COVID-19 pandemia did not change this trend. The procedural and technical details of MPS imaging reveal a high level of guideline conformity.</p>\",\"PeriodicalId\":19238,\"journal\":{\"name\":\"Nuklearmedizin-nuclear Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/6d/ff/10-1055-a-2084-7454.PMC10477021.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuklearmedizin-nuclear Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2084-7454\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuklearmedizin-nuclear Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2084-7454","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 1

摘要

目的:介绍2021年度心肌灌注SPECT (MPS)第九次调查结果。方法:对218份问卷进行评价,其中131份为执业医院(PR), 58份为医院(HO), 29份为大学医院(UH)。方括号内为2018年上次调查的结果。结果:共分析了133,057例[145,930]例(-8.8%)患者的MPS数据,其中131,868例[143,707]例为应激性MPS, 106,546例[121,899]例为休息性MPS。与官方数据的比较显示,54%的MPS被记录在案。从2018年到2021年,官方数据显示,警察人数每年都在增加。每个科室平均检查610[502]例MPS患者(+22%)。74%[69%]的应答者报告其MPS患者数量增加或没有变化。门诊心脏病专家一如既往地代表市长转诊组(68%[69%])。药理学应激的应用频率首次超过了几何测量(42%[51])。Regadenoson是最常用的。不同协议的使用几乎保持不变。主要采用为期两天的方案(49%[48%])。从多头摄像机(58%[72%])转向SPECT-CT系统(24%[17%])。33%[26%]的MPS进行衰减校正。88%[86%]的应激、88%[87%]的休息和87%[83%]的应激和休息MPS通过门控SPECT获得。72%[67%]的部门默认进行评分。无评分科室减少至13%[16%]。结论:2021年MPS研究显示,德国MPS成像的长期积极发展仍在继续。新冠肺炎疫情并未改变这一趋势。MPS成像的程序和技术细节显示高水平的指南符合性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Myocardial Perfusion SPECT and ATTR imaging 2021 in Germany: Results of the 9th Survey.

Aim: This paper presents the results of the 9th survey of myocardial perfusion SPECT (MPS) from the reporting year 2021.

Methods: 218 questionnaires (131 practices (PR), 58 hospitals (HO), 29 university hospitals (UH)) were evaluated. Results of the last survey 2018 are set in squared brackets.

Results: MPS data from a total of 133,057 [145,930] patients (-8.8%) with 131,868 [143,707] stress and 106,546 [121,899] rest MPS were analysed. A comparison with official data revealed that 54% all MPS were recorded. From 2018 to 2021, official data showed a every year an increase in MPS numbers. On average, 610 [502] MPS patients (+22%) were examined in each department. 74% [69%] of the responders reported an increase or no changes in their MPS patient numbers. Ambulatory care cardiologists represented as always, the mayor referral group (68% [69%]). For the first time, pharmacological stress was more frequently applied than ergometry (42% [51]). Regadenoson was mostly used. The use of the different protocols remained nearly unchanged. Two-day protocols were predominantly applied (49% [48%]). A shift from multi-headed cameras (58% [72%]) to SPECT-CT systems (24% [17%]) was found. Attenuation correction was performed in 33% [26%] of all MPS. 88% [86%] of all stress, 88% [87%] of all rest and 87% [83%] of all stress and rest MPS were acquired as gated SPECT. 72% [67%] of all departments performed scoring by default. The number of departments without scoring decreased to 13% [16%].

Conclusions: The MPS Study 2021 shows that the long-term positive development of MPS imaging in Germany is continuing. The COVID-19 pandemia did not change this trend. The procedural and technical details of MPS imaging reveal a high level of guideline conformity.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.70
自引率
13.30%
发文量
267
审稿时长
>12 weeks
期刊介绍: Als Standes- und Fachorgan (Organ von Deutscher Gesellschaft für Nuklearmedizin (DGN), Österreichischer Gesellschaft für Nuklearmedizin und Molekulare Bildgebung (ÖGN), Schweizerischer Gesellschaft für Nuklearmedizin (SGNM, SSNM)) von hohem wissenschaftlichen Anspruch befasst sich die CME-zertifizierte Nuklearmedizin/ NuclearMedicine mit Diagnostik und Therapie in der Nuklearmedizin und dem Strahlenschutz: Originalien, Übersichtsarbeiten, Referate und Kongressberichte stellen aktuelle Themen der Diagnose und Therapie dar. Ausführliche Berichte aus den DGN-Arbeitskreisen, Nachrichten aus Forschung und Industrie sowie Beschreibungen innovativer technischer Geräte, Einrichtungen und Systeme runden das Konzept ab. Die Abstracts der Jahrestagungen dreier europäischer Fachgesellschaften sind Bestandteil der Kongressausgaben. Nuklearmedizin erscheint regelmäßig mit sechs Ausgaben pro Jahr und richtet sich vor allem an Nuklearmediziner, Radiologen, Strahlentherapeuten, Medizinphysiker und Radiopharmazeuten.
期刊最新文献
The Medical Informatics Initiative and the Network University Medicine - Perspectives for Nuclear Medicine. Combined morphologic-metabolic biomarkers from [18F]FDG-PET/CT stratify prognostic groups in low-risk NSCLC. NuklearMedizin 2024: Abstract-Einreichung bis zum 1. November geöffnet! DGN-Forschungs- und -Förderpreise Preisverleihungen
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1