即时检测与金标准实验室方法在血脂测量中的比较。

IF 0.7 4区 医学 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS Cardiovascular Journal of Africa Pub Date : 2023-08-31 DOI:10.5830/CVJA-2023-039
Brett S Mansfield, Belinda Stevens, Frederick J Raal, Farzahna Mohamed
{"title":"即时检测与金标准实验室方法在血脂测量中的比较。","authors":"Brett S Mansfield,&nbsp;Belinda Stevens,&nbsp;Frederick J Raal,&nbsp;Farzahna Mohamed","doi":"10.5830/CVJA-2023-039","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cardiovascular disease is the leading cause of mortality worldwide, with dyslipidaemia being one of the major risk factors. Point-of-care testing (POCT) allows for the rapid measurement of serum lipids. The aim of this study was to assess the accuracy of serum lipid measurement by the Fujifilm<sup>™</sup> NX700 POCT compared to a gold-standard clinical laboratory method (Medpace, Leuven, Belgium).</p><p><strong>Methods: </strong>This was a prospective, observational study conducted at the Lipid Clinic at Charlotte Maxeke Johannesburg Academic Hospital from July to September 2022. Participants were known to have a lipid disorder, most commonly, familial hypercholesterolaemia. Samples sent for lipid measurement by standard laboratory methods were simultaneously measured by the Fujifilm<sup>™</sup> NX700 POCT.</p><p><strong>Results: </strong>Lipograms evaluating total cholesterol (TC), triglycerides (TG), high-density lipoprotein cholesterol (HDL-C) and calculated low-density lipoprotein cholesterol (LDL-C) were obtained from 115 participants. No statistically significant difference was noted between the parameters tested on the different platforms. The Fujifilm<sup>™</sup> NX700 POCT correctly identified > 91% of serum lipid results as normal or abnormal, as defined by NCEP-ATP III criteria, and exhibited good sensitivity and specificity for each parameter. Lin's concordance correlation coefficient demonstrated a strong correlation for all parameters; TC (ρ<sub>c</sub> = 0.9861), HDL-C (ρ<sub>c</sub> = 0.95919), LDL-C (ρ<sub>c</sub> = 0.98134) and TG (ρ<sub>c</sub> = 0.92775). Bland-Altman plots identified low bias and a good level of agreement between the two test methods.</p><p><strong>Conclusion: </strong>The Fujifilm<sup>™</sup> NX700 POCT compared favourably with gold-standard laboratory methods in the determination of serum lipid measurements, allowing for rapid screening at the primary healthcare level.</p>","PeriodicalId":9434,"journal":{"name":"Cardiovascular Journal of Africa","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2023-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Point-of-care testing compared to gold-standard laboratory methods in the measurement of serum lipids.\",\"authors\":\"Brett S Mansfield,&nbsp;Belinda Stevens,&nbsp;Frederick J Raal,&nbsp;Farzahna Mohamed\",\"doi\":\"10.5830/CVJA-2023-039\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Cardiovascular disease is the leading cause of mortality worldwide, with dyslipidaemia being one of the major risk factors. Point-of-care testing (POCT) allows for the rapid measurement of serum lipids. The aim of this study was to assess the accuracy of serum lipid measurement by the Fujifilm<sup>™</sup> NX700 POCT compared to a gold-standard clinical laboratory method (Medpace, Leuven, Belgium).</p><p><strong>Methods: </strong>This was a prospective, observational study conducted at the Lipid Clinic at Charlotte Maxeke Johannesburg Academic Hospital from July to September 2022. Participants were known to have a lipid disorder, most commonly, familial hypercholesterolaemia. Samples sent for lipid measurement by standard laboratory methods were simultaneously measured by the Fujifilm<sup>™</sup> NX700 POCT.</p><p><strong>Results: </strong>Lipograms evaluating total cholesterol (TC), triglycerides (TG), high-density lipoprotein cholesterol (HDL-C) and calculated low-density lipoprotein cholesterol (LDL-C) were obtained from 115 participants. No statistically significant difference was noted between the parameters tested on the different platforms. The Fujifilm<sup>™</sup> NX700 POCT correctly identified > 91% of serum lipid results as normal or abnormal, as defined by NCEP-ATP III criteria, and exhibited good sensitivity and specificity for each parameter. Lin's concordance correlation coefficient demonstrated a strong correlation for all parameters; TC (ρ<sub>c</sub> = 0.9861), HDL-C (ρ<sub>c</sub> = 0.95919), LDL-C (ρ<sub>c</sub> = 0.98134) and TG (ρ<sub>c</sub> = 0.92775). Bland-Altman plots identified low bias and a good level of agreement between the two test methods.</p><p><strong>Conclusion: </strong>The Fujifilm<sup>™</sup> NX700 POCT compared favourably with gold-standard laboratory methods in the determination of serum lipid measurements, allowing for rapid screening at the primary healthcare level.</p>\",\"PeriodicalId\":9434,\"journal\":{\"name\":\"Cardiovascular Journal of Africa\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2023-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Journal of Africa\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5830/CVJA-2023-039\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Journal of Africa","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5830/CVJA-2023-039","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:心血管疾病是全球死亡的主要原因,而血脂异常是主要危险因素之一。即时检测(POCT)允许快速测量血脂。本研究的目的是评估使用Fujifilm™NX700 POCT与金标准临床实验室方法(Medpace, Leuven, Belgium)进行血脂测量的准确性。方法:这是一项前瞻性观察性研究,于2022年7月至9月在Charlotte Maxeke约翰内斯堡学术医院脂质诊所进行。参与者已知有脂质紊乱,最常见的是家族性高胆固醇血症。通过标准实验室方法送去脂质测量的样品同时由Fujifilm™NX700 POCT进行测量。结果:获得了115名参与者的总胆固醇(TC)、甘油三酯(TG)、高密度脂蛋白胆固醇(HDL-C)和计算出的低密度脂蛋白胆固醇(LDL-C)的脂蛋白图。在不同平台上测试的参数之间没有统计学上的显著差异。Fujifilm™NX700 POCT正确识别> 91%的血脂结果为正常或异常(根据NCEP-ATP III标准定义),并对每个参数表现出良好的敏感性和特异性。林氏一致性相关系数在各参数间表现出较强的相关性;TC (ρc = 0.9861)、HDL-C (ρc = 0.95919)、LDL-C (ρc = 0.98134)、TG (ρc = 0.92775)。Bland-Altman图确定了两种检验方法之间的低偏差和良好的一致性。结论:Fujifilm™NX700 POCT在测定血脂测量方面优于金标准实验室方法,可在初级保健水平进行快速筛查。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Point-of-care testing compared to gold-standard laboratory methods in the measurement of serum lipids.

Background: Cardiovascular disease is the leading cause of mortality worldwide, with dyslipidaemia being one of the major risk factors. Point-of-care testing (POCT) allows for the rapid measurement of serum lipids. The aim of this study was to assess the accuracy of serum lipid measurement by the Fujifilm NX700 POCT compared to a gold-standard clinical laboratory method (Medpace, Leuven, Belgium).

Methods: This was a prospective, observational study conducted at the Lipid Clinic at Charlotte Maxeke Johannesburg Academic Hospital from July to September 2022. Participants were known to have a lipid disorder, most commonly, familial hypercholesterolaemia. Samples sent for lipid measurement by standard laboratory methods were simultaneously measured by the Fujifilm NX700 POCT.

Results: Lipograms evaluating total cholesterol (TC), triglycerides (TG), high-density lipoprotein cholesterol (HDL-C) and calculated low-density lipoprotein cholesterol (LDL-C) were obtained from 115 participants. No statistically significant difference was noted between the parameters tested on the different platforms. The Fujifilm NX700 POCT correctly identified > 91% of serum lipid results as normal or abnormal, as defined by NCEP-ATP III criteria, and exhibited good sensitivity and specificity for each parameter. Lin's concordance correlation coefficient demonstrated a strong correlation for all parameters; TC (ρc = 0.9861), HDL-C (ρc = 0.95919), LDL-C (ρc = 0.98134) and TG (ρc = 0.92775). Bland-Altman plots identified low bias and a good level of agreement between the two test methods.

Conclusion: The Fujifilm NX700 POCT compared favourably with gold-standard laboratory methods in the determination of serum lipid measurements, allowing for rapid screening at the primary healthcare level.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cardiovascular Journal of Africa
Cardiovascular Journal of Africa CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
1.30
自引率
0.00%
发文量
0
审稿时长
4-8 weeks
期刊介绍: The Cardiovascular Journal of Africa (CVJA) is an international peer-reviewed journal that keeps cardiologists up to date with advances in the diagnosis and treatment of cardiovascular disease. Topics covered include coronary disease, electrophysiology, valve disease, imaging techniques, congenital heart disease (fetal, paediatric and adult), heart failure, surgery, and basic science.
期刊最新文献
Disparities in patients' understanding of cardiovascular disease management. High intracardiac clot burden in a young mother with peripartum cardiomyopathy in Uganda. The temporal relationship between body composition and cardiometabolic profiles in an HIV-infected (on antiretroviral therapy) versus HIV-free Western Cape study population. Evaluation of cardiac function in paediatric Wilson's disease patients with advanced echocardiographic modalities (strain and strain rate echocardiography). The role of C-reactive protein:albumin ratio and Neutrophil:lymphocyte ratio in predicting coronary artery disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1