开发一种使用现有量表评估膝骨关节炎患者功能的通用指标。

IF 1.1 4区 医学 Q3 REHABILITATION Turkish Journal of Physical Medicine and Rehabilitation Pub Date : 2023-09-01 DOI:10.5606/tftrd.2023.12387
Pervin Demir, Ayşe Adile Küçükdeveci, Şehim Kutlay, Atilla Halil Elhan
{"title":"开发一种使用现有量表评估膝骨关节炎患者功能的通用指标。","authors":"Pervin Demir,&nbsp;Ayşe Adile Küçükdeveci,&nbsp;Şehim Kutlay,&nbsp;Atilla Halil Elhan","doi":"10.5606/tftrd.2023.12387","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Various scales exist to assess different domains of functioning in knee osteoarthritis (OA). This study aimed to explore whether it is possible to develop a common metric (CM) from the frequently used scales to assess functioning in knee OA.</p><p><strong>Patients and methods: </strong>The methodological study evaluated 411 patients (81 males, 330 females; mean age: 61.8±10.5 years; range, 41 to 88 years) with knee OA. Data from the Health Assessment Questionnaire, Oxford Knee Score, Medical Outcomes Study Short Form 36, Knee Injury and Osteoarthritis Outcome Score, Western Ontario and McMaster Universities Arthritis Index, and the Nottingham Health Profile were used, and the items focusing on self-care, mobility, and domestic activity domains based on the activities and participation component of the International Classification of Functioning, Disability, and Health were included. Concurrent calibration was performed to combine the items of the scales. The CM parameters were estimated using the Rasch measurement model. Reliability was assessed using the person separation index. The CM was utilized to generate a transformation table to convert the scale scores to each other based on the reference metric score.</p><p><strong>Results: </strong>Each scale fitted the Rasch model. Item invariance was achieved for the CM (p=0.775). The CM had a person separation index of 0.827. Age, sex, and disease duration did not cause difference in item functions. The CM satisfied the assumptions of unidimensionality and local independence.</p><p><strong>Conclusion: </strong>A reliable CM was created from the commonly used scales to measure functioning in individuals with knee OA. Thus, clinicians and researchers can refer to the transformation table to directly compare scores of those scales and use them interchangeably.</p>","PeriodicalId":56043,"journal":{"name":"Turkish Journal of Physical Medicine and Rehabilitation","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/99/8c/TurkJPhysMedRehab-69-350.PMC10478544.pdf","citationCount":"0","resultStr":"{\"title\":\"Developing a common metric using current scales for assessing functioning in patients with knee osteoarthritis.\",\"authors\":\"Pervin Demir,&nbsp;Ayşe Adile Küçükdeveci,&nbsp;Şehim Kutlay,&nbsp;Atilla Halil Elhan\",\"doi\":\"10.5606/tftrd.2023.12387\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Various scales exist to assess different domains of functioning in knee osteoarthritis (OA). This study aimed to explore whether it is possible to develop a common metric (CM) from the frequently used scales to assess functioning in knee OA.</p><p><strong>Patients and methods: </strong>The methodological study evaluated 411 patients (81 males, 330 females; mean age: 61.8±10.5 years; range, 41 to 88 years) with knee OA. Data from the Health Assessment Questionnaire, Oxford Knee Score, Medical Outcomes Study Short Form 36, Knee Injury and Osteoarthritis Outcome Score, Western Ontario and McMaster Universities Arthritis Index, and the Nottingham Health Profile were used, and the items focusing on self-care, mobility, and domestic activity domains based on the activities and participation component of the International Classification of Functioning, Disability, and Health were included. Concurrent calibration was performed to combine the items of the scales. The CM parameters were estimated using the Rasch measurement model. Reliability was assessed using the person separation index. The CM was utilized to generate a transformation table to convert the scale scores to each other based on the reference metric score.</p><p><strong>Results: </strong>Each scale fitted the Rasch model. Item invariance was achieved for the CM (p=0.775). The CM had a person separation index of 0.827. Age, sex, and disease duration did not cause difference in item functions. The CM satisfied the assumptions of unidimensionality and local independence.</p><p><strong>Conclusion: </strong>A reliable CM was created from the commonly used scales to measure functioning in individuals with knee OA. Thus, clinicians and researchers can refer to the transformation table to directly compare scores of those scales and use them interchangeably.</p>\",\"PeriodicalId\":56043,\"journal\":{\"name\":\"Turkish Journal of Physical Medicine and Rehabilitation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/99/8c/TurkJPhysMedRehab-69-350.PMC10478544.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turkish Journal of Physical Medicine and Rehabilitation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5606/tftrd.2023.12387\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"REHABILITATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Physical Medicine and Rehabilitation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5606/tftrd.2023.12387","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

摘要

目的:存在各种量表来评估膝关节骨关节炎(OA)的不同功能领域。本研究旨在探讨是否有可能从常用的量表中开发一种通用的度量(CM)来评估膝关节OA的功能。患者和方法:方法学研究评估了411例患者(男性81例,女性330例;平均年龄:61.8±10.5岁;范围,41 - 88岁),膝关节OA。数据来自健康评估问卷、牛津膝关节评分、医疗结果研究简表36、膝关节损伤和骨关节炎结果评分、西安大略省和麦克马斯特大学关节炎指数和诺丁汉健康概况,并包括基于国际功能、残疾和健康分类的活动和参与部分的关注自我保健、活动和家庭活动领域的项目。同时进行校准以合并量表的项目。采用Rasch测量模型估计CM参数。采用人分离指数评估信度。利用CM生成一个转换表,以参考度量分数为基础将尺度分数相互转换。结果:各量表均符合Rasch模型。CM实现了项目不变性(p=0.775)。CM的人分离指数为0.827。年龄、性别和疾病持续时间对项目功能没有影响。该模型满足单维性和局部独立性的假设。结论:从常用的量表中创建了一个可靠的CM来测量膝关节OA患者的功能。因此,临床医生和研究人员可以参考转换表直接比较这些量表的分数,并互换使用它们。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Developing a common metric using current scales for assessing functioning in patients with knee osteoarthritis.

Objectives: Various scales exist to assess different domains of functioning in knee osteoarthritis (OA). This study aimed to explore whether it is possible to develop a common metric (CM) from the frequently used scales to assess functioning in knee OA.

Patients and methods: The methodological study evaluated 411 patients (81 males, 330 females; mean age: 61.8±10.5 years; range, 41 to 88 years) with knee OA. Data from the Health Assessment Questionnaire, Oxford Knee Score, Medical Outcomes Study Short Form 36, Knee Injury and Osteoarthritis Outcome Score, Western Ontario and McMaster Universities Arthritis Index, and the Nottingham Health Profile were used, and the items focusing on self-care, mobility, and domestic activity domains based on the activities and participation component of the International Classification of Functioning, Disability, and Health were included. Concurrent calibration was performed to combine the items of the scales. The CM parameters were estimated using the Rasch measurement model. Reliability was assessed using the person separation index. The CM was utilized to generate a transformation table to convert the scale scores to each other based on the reference metric score.

Results: Each scale fitted the Rasch model. Item invariance was achieved for the CM (p=0.775). The CM had a person separation index of 0.827. Age, sex, and disease duration did not cause difference in item functions. The CM satisfied the assumptions of unidimensionality and local independence.

Conclusion: A reliable CM was created from the commonly used scales to measure functioning in individuals with knee OA. Thus, clinicians and researchers can refer to the transformation table to directly compare scores of those scales and use them interchangeably.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Turkish Journal of Physical Medicine and Rehabilitation
Turkish Journal of Physical Medicine and Rehabilitation Health Professions-Physical Therapy, Sports Therapy and Rehabilitation
CiteScore
2.20
自引率
0.00%
发文量
0
期刊介绍: The Turkish Journal of Physical Medicine and Rehabilitation (Formerly published as Türkiye Fiziksel Tıp ve Rehabilitasyon Dergisi) is the official journal of the Turkish Society of Physical Medicine and Rehabilitation. The journal is an international open-access, double-blind peer-reviewed periodical journal bringing the latest developments in all aspects of physical medicine and rehabilitation, and related fields. The journal publishes original articles, review articles, editorials, case reports (limited), letters to the editors. The target readership includes academic members, specialists, residents working in the fields of Physical Medicine and Rehabilitation. The language of the journal is English and it is published quarterly (in March, June, September, and December).
期刊最新文献
Comprehensive analysis of publication of physical medicine and rehabilitation theses in Türkiye between years 2010 and 2020: Academic productivity and related factors. Effect of platelet-rich plasma injections versus placebo on pain and quality of life in patients with hip osteoarthritis: A double-blind, randomized clinical trial. Local ozone injection compared to local glucocorticoid injection in carpal tunnel syndrome: A randomized controlled trial. Which aerobic exercise is more effective in Parkinson's patients? Cycle ergometer versus body weight-supported treadmill. Adherence to complete decongestive therapy in patients with postmastectomy lymphedema and related factors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1