欧姆龙 HeartGuide 与 Welch Allyn ProBP 3400 血压计的比较。

IF 1.2 4区 医学 Q4 PERIPHERAL VASCULAR DISEASE Blood Pressure Monitoring Pub Date : 2024-02-01 Epub Date: 2023-09-14 DOI:10.1097/MBP.0000000000000672
Brianna D Harfmann, Sylvia E Neph, Mason M Gardner, Audrey A Plouffe, Jennifer R Vranish, Alexander H K Montoye
{"title":"欧姆龙 HeartGuide 与 Welch Allyn ProBP 3400 血压计的比较。","authors":"Brianna D Harfmann, Sylvia E Neph, Mason M Gardner, Audrey A Plouffe, Jennifer R Vranish, Alexander H K Montoye","doi":"10.1097/MBP.0000000000000672","DOIUrl":null,"url":null,"abstract":"<p><p>Hypertension affects approximately 100 million U.S. adults and is the leading single contributing risk factor to all-cause mortality. Accurate blood pressure (BP) measurement is essential in the treatment of BP, and a number of devices exist for monitoring. Recently, a new watch-type design was released, the Omron HeartGuide (BP8000), with claims to provide clinically accurate BP measurement while also tracking activity and sleep similar to smart watches. The aim of this research was done in two studies: (1) evaluation of the HeartGuide device for measurement of resting BP and heart rate (HR); and (2) assessment of the HeartGuide for BP, HR, step-counting and sleep monitoring during activities of daily living. Study 1 compared the Omron HeartGuide to the previously validated Welch Allyn ProBP 3400 following a modified version of the Universal Standard for validation of BP measuring devices set by the AAMI/ESH/ISO. While resting HR measured by the HeartGuide was similar to Welch Allyn measures, both systolic and diastolic BP were significantly lower ( P ≤0.001), with differences of 10.4 (11.1) and 3.2 (10.0) mmHg, respectively. Study 2 compared HeartGuide measures to Welch Allyn measures for BP, HR, steps and sleep during various body positions (supine, seated, standing), physiological stressors (cold pressor test, lower body submersion, exercise), and free-living. The HeartGuide significantly underestimated BP though provided accurate HR during most conditions. It also significantly underestimated steps, but reported sleep measures similar to those subjectively reported. Based on the significant differences between the HeartGuide and Welch Allyn, our data indicate the HeartGuide is not a suitable replacement for existing BP monitors.</p>","PeriodicalId":8950,"journal":{"name":"Blood Pressure Monitoring","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of the Omron HeartGuide to the Welch Allyn ProBP 3400 blood pressure monitor.\",\"authors\":\"Brianna D Harfmann, Sylvia E Neph, Mason M Gardner, Audrey A Plouffe, Jennifer R Vranish, Alexander H K Montoye\",\"doi\":\"10.1097/MBP.0000000000000672\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Hypertension affects approximately 100 million U.S. adults and is the leading single contributing risk factor to all-cause mortality. Accurate blood pressure (BP) measurement is essential in the treatment of BP, and a number of devices exist for monitoring. Recently, a new watch-type design was released, the Omron HeartGuide (BP8000), with claims to provide clinically accurate BP measurement while also tracking activity and sleep similar to smart watches. The aim of this research was done in two studies: (1) evaluation of the HeartGuide device for measurement of resting BP and heart rate (HR); and (2) assessment of the HeartGuide for BP, HR, step-counting and sleep monitoring during activities of daily living. Study 1 compared the Omron HeartGuide to the previously validated Welch Allyn ProBP 3400 following a modified version of the Universal Standard for validation of BP measuring devices set by the AAMI/ESH/ISO. While resting HR measured by the HeartGuide was similar to Welch Allyn measures, both systolic and diastolic BP were significantly lower ( P ≤0.001), with differences of 10.4 (11.1) and 3.2 (10.0) mmHg, respectively. Study 2 compared HeartGuide measures to Welch Allyn measures for BP, HR, steps and sleep during various body positions (supine, seated, standing), physiological stressors (cold pressor test, lower body submersion, exercise), and free-living. The HeartGuide significantly underestimated BP though provided accurate HR during most conditions. It also significantly underestimated steps, but reported sleep measures similar to those subjectively reported. Based on the significant differences between the HeartGuide and Welch Allyn, our data indicate the HeartGuide is not a suitable replacement for existing BP monitors.</p>\",\"PeriodicalId\":8950,\"journal\":{\"name\":\"Blood Pressure Monitoring\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Blood Pressure Monitoring\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MBP.0000000000000672\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blood Pressure Monitoring","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MBP.0000000000000672","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/14 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

高血压影响着大约 1 亿美国成年人,是导致全因死亡的首要风险因素。准确测量血压对治疗高血压至关重要,目前已有许多设备可用于监测血压。最近,欧姆龙发布了一款新型手表式设计--欧姆龙HeartGuide (BP8000),号称能提供临床上准确的血压测量,同时还能跟踪活动和睡眠情况,与智能手表类似。这项研究的目的是通过两项研究来实现的:(1) 对测量静息血压和心率 (HR) 的 HeartGuide 设备进行评估;(2) 对日常生活活动中的血压、心率、步数和睡眠监测的 HeartGuide 进行评估。研究 1 比较了欧姆龙 HeartGuide 和之前经过验证的 Welch Allyn ProBP 3400,后者采用的是 AAMI/ESH/ISO 制定的血压测量设备验证通用标准的修订版。虽然 HeartGuide 测得的静息心率与 Welch Allyn 的测量结果相似,但收缩压和舒张压都明显降低(P ≤0.001),差异分别为 10.4 (11.1) mmHg 和 3.2 (10.0) mmHg。研究 2 比较了在不同体位(仰卧、坐位、站立)、生理压力(冷压试验、下半身浸入水中、运动)和自由生活期间,HeartGuide 测量值与 Welch Allyn 测量值在血压、心率、步数和睡眠方面的差异。在大多数情况下,HeartGuide 虽然能提供准确的心率,但却严重低估了血压。它也明显低估了步数,但报告的睡眠测量结果与主观报告的结果相似。基于 HeartGuide 和 Welch Allyn 之间的显著差异,我们的数据表明,HeartGuide 并不适合替代现有的血压计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of the Omron HeartGuide to the Welch Allyn ProBP 3400 blood pressure monitor.

Hypertension affects approximately 100 million U.S. adults and is the leading single contributing risk factor to all-cause mortality. Accurate blood pressure (BP) measurement is essential in the treatment of BP, and a number of devices exist for monitoring. Recently, a new watch-type design was released, the Omron HeartGuide (BP8000), with claims to provide clinically accurate BP measurement while also tracking activity and sleep similar to smart watches. The aim of this research was done in two studies: (1) evaluation of the HeartGuide device for measurement of resting BP and heart rate (HR); and (2) assessment of the HeartGuide for BP, HR, step-counting and sleep monitoring during activities of daily living. Study 1 compared the Omron HeartGuide to the previously validated Welch Allyn ProBP 3400 following a modified version of the Universal Standard for validation of BP measuring devices set by the AAMI/ESH/ISO. While resting HR measured by the HeartGuide was similar to Welch Allyn measures, both systolic and diastolic BP were significantly lower ( P ≤0.001), with differences of 10.4 (11.1) and 3.2 (10.0) mmHg, respectively. Study 2 compared HeartGuide measures to Welch Allyn measures for BP, HR, steps and sleep during various body positions (supine, seated, standing), physiological stressors (cold pressor test, lower body submersion, exercise), and free-living. The HeartGuide significantly underestimated BP though provided accurate HR during most conditions. It also significantly underestimated steps, but reported sleep measures similar to those subjectively reported. Based on the significant differences between the HeartGuide and Welch Allyn, our data indicate the HeartGuide is not a suitable replacement for existing BP monitors.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Blood Pressure Monitoring
Blood Pressure Monitoring 医学-外周血管病
CiteScore
2.00
自引率
7.70%
发文量
110
审稿时长
>12 weeks
期刊介绍: Blood Pressure Monitoring is devoted to original research in blood pressure measurement and blood pressure variability. It includes device technology, analytical methodology of blood pressure over time and its variability, clinical trials - including, but not limited to, pharmacology - involving blood pressure monitoring, blood pressure reactivity, patient evaluation, and outcomes and effectiveness research. This innovative journal contains papers dealing with all aspects of manual, automated, and ambulatory monitoring. Basic and clinical science papers are considered although the emphasis is on clinical medicine. Submitted articles undergo a preliminary review by the editor. Some articles may be returned to authors without further consideration. Those being considered for publication will undergo further assessment and peer-review by the editors and those invited to do so from a reviewer pool.
期刊最新文献
Does greater adherence to a healthy dietary pattern correspond to a better body composition and cardiorespiratory fitness in adults with overweight and primary hypertension? Data from the EXERDIET-HTA study. Validation of the TMB-2296-BT blood pressure monitor in adults according to the ISO 81060-2:2018 + Amd.1:2020. Inflammation-based markers, especially the uric acid/albumin ratio, are associated with non-dipper pattern in newly diagnosed treatment-naive hypertensive patients. Validating the accuracy of Omron HEM-7372T1-AZAZ (BP5460) in monitoring blood pressure according to the ISO 81060-2:2018+Amd 1:2020 protocol in the general population. Blood pressure variability at rest and during pressor challenges in patients with acute ischemic stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1