高频线性探针横波弹性成像用于肾移植监测:方法学研究。

IF 2.1 4区 医学 Q3 HEMATOLOGY Clinical hemorheology and microcirculation Pub Date : 2023-01-01 DOI:10.3233/CH-221668
Daopeng Yang, Bowen Zhuang, Yanling Zheng, Ming Xu, Jinhua Lin, Xiaoer Zhang, Changxi Wang, Xiaoyan Xie, Gang Huang, Xiaohua Xie, Yan Wang
{"title":"高频线性探针横波弹性成像用于肾移植监测:方法学研究。","authors":"Daopeng Yang,&nbsp;Bowen Zhuang,&nbsp;Yanling Zheng,&nbsp;Ming Xu,&nbsp;Jinhua Lin,&nbsp;Xiaoer Zhang,&nbsp;Changxi Wang,&nbsp;Xiaoyan Xie,&nbsp;Gang Huang,&nbsp;Xiaohua Xie,&nbsp;Yan Wang","doi":"10.3233/CH-221668","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To investigate the influencing factors of the image quality of shear wave elastography (SWE) performed using a high-frequency probe and its reproducibility for renal allografts.</p><p><strong>Methods: </strong>A total of 211 patients with transplanted kidneys who underwent SWE examination performed using high-frequency or low-frequency probes were recruited for the study. The reproducibility of inter- and intraobserver agreements were analysed by using the intraclass correlation coefficient (ICC). According to the colour filling of the area of interest and imaging noise when conducting SWE, the image quality was classified as three grades: \"good\", \"common\", and \"poor\". A logistic regression was used to analyse the independent factors for SWE quality.</p><p><strong>Results: </strong>In the comparative analysis, high frequency, transection measurement and middle pole were selected as the appropriate measurement methods. Regarding reproducibility, the ICCs) of the intra- and interobserver agreements were 0.85 and 0.77, respectively. Multivariate analysis indicated that only the skin allograft distance and kidney width were independent variables for SWE quality. In the subgroup analysis of the skin-allograft distance, the \"good\" and \"common\" rates of images decreased as the distance increased, but the CV (coefficients of variation) showed the opposite trend. The SWE quality of kidney width <5.4 cm was significantly better than that of kidney width ≥5.4 cm.</p><p><strong>Conclusions: </strong>High-frequency SWE can be used in the evaluation of transplanted kidneys due to its good repeatability and high successful measurement rate, but we should pay attention to the influence of the skin-allograft distance and kidney width on SWE quality.</p>","PeriodicalId":10425,"journal":{"name":"Clinical hemorheology and microcirculation","volume":"84 2","pages":"165-176"},"PeriodicalIF":2.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Shear wave elastography using high-frequency linear probe for kidney transplant monitoring: A methodological study.\",\"authors\":\"Daopeng Yang,&nbsp;Bowen Zhuang,&nbsp;Yanling Zheng,&nbsp;Ming Xu,&nbsp;Jinhua Lin,&nbsp;Xiaoer Zhang,&nbsp;Changxi Wang,&nbsp;Xiaoyan Xie,&nbsp;Gang Huang,&nbsp;Xiaohua Xie,&nbsp;Yan Wang\",\"doi\":\"10.3233/CH-221668\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To investigate the influencing factors of the image quality of shear wave elastography (SWE) performed using a high-frequency probe and its reproducibility for renal allografts.</p><p><strong>Methods: </strong>A total of 211 patients with transplanted kidneys who underwent SWE examination performed using high-frequency or low-frequency probes were recruited for the study. The reproducibility of inter- and intraobserver agreements were analysed by using the intraclass correlation coefficient (ICC). According to the colour filling of the area of interest and imaging noise when conducting SWE, the image quality was classified as three grades: \\\"good\\\", \\\"common\\\", and \\\"poor\\\". A logistic regression was used to analyse the independent factors for SWE quality.</p><p><strong>Results: </strong>In the comparative analysis, high frequency, transection measurement and middle pole were selected as the appropriate measurement methods. Regarding reproducibility, the ICCs) of the intra- and interobserver agreements were 0.85 and 0.77, respectively. Multivariate analysis indicated that only the skin allograft distance and kidney width were independent variables for SWE quality. In the subgroup analysis of the skin-allograft distance, the \\\"good\\\" and \\\"common\\\" rates of images decreased as the distance increased, but the CV (coefficients of variation) showed the opposite trend. The SWE quality of kidney width <5.4 cm was significantly better than that of kidney width ≥5.4 cm.</p><p><strong>Conclusions: </strong>High-frequency SWE can be used in the evaluation of transplanted kidneys due to its good repeatability and high successful measurement rate, but we should pay attention to the influence of the skin-allograft distance and kidney width on SWE quality.</p>\",\"PeriodicalId\":10425,\"journal\":{\"name\":\"Clinical hemorheology and microcirculation\",\"volume\":\"84 2\",\"pages\":\"165-176\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical hemorheology and microcirculation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3233/CH-221668\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical hemorheology and microcirculation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3233/CH-221668","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 1

摘要

目的:探讨高频探针横波弹性成像(SWE)对同种异体肾脏移植成像质量的影响因素及其再现性。方法:211例接受高频或低频探针SWE检查的肾移植患者被纳入研究。使用类内相关系数(ICC)分析了观察者间和观察者内部一致性的可重复性。根据进行SWE时感兴趣区域的色彩填充和成像噪声,将图像质量分为“好”、“一般”和“差”三个等级。采用logistic回归分析影响SWE质量的独立因素。结果:在对比分析中,选择高频测量、横断面测量和中极测量作为合适的测量方法。在可重复性方面,观察者内部和观察者之间的ICCs分别为0.85和0.77。多因素分析表明,只有同种异体皮肤移植距离和肾脏宽度是SWE质量的独立变量。在同种异体皮肤移植距离亚组分析中,图像的“良好”率和“一般”率随距离的增加而降低,但变异系数(CV)呈现相反的趋势。结论:高频SWE重复性好,测量成功率高,可用于移植肾的评价,但应注意同种异体皮肤移植距离和肾宽度对SWE质量的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Shear wave elastography using high-frequency linear probe for kidney transplant monitoring: A methodological study.

Objectives: To investigate the influencing factors of the image quality of shear wave elastography (SWE) performed using a high-frequency probe and its reproducibility for renal allografts.

Methods: A total of 211 patients with transplanted kidneys who underwent SWE examination performed using high-frequency or low-frequency probes were recruited for the study. The reproducibility of inter- and intraobserver agreements were analysed by using the intraclass correlation coefficient (ICC). According to the colour filling of the area of interest and imaging noise when conducting SWE, the image quality was classified as three grades: "good", "common", and "poor". A logistic regression was used to analyse the independent factors for SWE quality.

Results: In the comparative analysis, high frequency, transection measurement and middle pole were selected as the appropriate measurement methods. Regarding reproducibility, the ICCs) of the intra- and interobserver agreements were 0.85 and 0.77, respectively. Multivariate analysis indicated that only the skin allograft distance and kidney width were independent variables for SWE quality. In the subgroup analysis of the skin-allograft distance, the "good" and "common" rates of images decreased as the distance increased, but the CV (coefficients of variation) showed the opposite trend. The SWE quality of kidney width <5.4 cm was significantly better than that of kidney width ≥5.4 cm.

Conclusions: High-frequency SWE can be used in the evaluation of transplanted kidneys due to its good repeatability and high successful measurement rate, but we should pay attention to the influence of the skin-allograft distance and kidney width on SWE quality.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.30
自引率
33.30%
发文量
170
期刊介绍: Clinical Hemorheology and Microcirculation, a peer-reviewed international scientific journal, serves as an aid to understanding the flow properties of blood and the relationship to normal and abnormal physiology. The rapidly expanding science of hemorheology concerns blood, its components and the blood vessels with which blood interacts. It includes perihemorheology, i.e., the rheology of fluid and structures in the perivascular and interstitial spaces as well as the lymphatic system. The clinical aspects include pathogenesis, symptomatology and diagnostic methods, and the fields of prophylaxis and therapy in all branches of medicine and surgery, pharmacology and drug research. The endeavour of the Editors-in-Chief and publishers of Clinical Hemorheology and Microcirculation is to bring together contributions from those working in various fields related to blood flow all over the world. The editors of Clinical Hemorheology and Microcirculation are from those countries in Europe, Asia, Australia and America where appreciable work in clinical hemorheology and microcirculation is being carried out. Each editor takes responsibility to decide on the acceptance of a manuscript. He is required to have the manuscript appraised by two referees and may be one of them himself. The executive editorial office, to which the manuscripts have been submitted, is responsible for rapid handling of the reviewing process. Clinical Hemorheology and Microcirculation accepts original papers, brief communications, mini-reports and letters to the Editors-in-Chief. Review articles, providing general views and new insights into related subjects, are regularly invited by the Editors-in-Chief. Proceedings of international and national conferences on clinical hemorheology (in original form or as abstracts) complete the range of editorial features.
期刊最新文献
Rosuvastatin inhibit ox-LDL-induced platelet activation by the p38/MAPK pathway. PANoptosis and cardiovascular disease: The preventive role of exercise training. Utility of ultrasound in the perioperative phase of carotid endarterectomy and carotid artery stent implantation. Neutrophil/HDL-C, Lymphocyte/HDL-C and Monocyte/HDL-C in subjects with asymptomatic carotid atherosclerosis. Evaluating diagnostic significance: The utilization of elastography and contrast-enhanced ultrasound for differential diagnosis in breast lesions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1