氧化锆和 PEKK 种植体固位冠的表面磨损和固位力。

IF 1.1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE European Journal of Prosthodontics and Restorative Dentistry Pub Date : 2024-02-29 DOI:10.1922/EJPRD_2524Emera08
R M K Emera, O Askar
{"title":"氧化锆和 PEKK 种植体固位冠的表面磨损和固位力。","authors":"R M K Emera, O Askar","doi":"10.1922/EJPRD_2524Emera08","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to evaluate the surface wear and retention force of telescopic attachments made of zirconia primary crowns and poly-ether- ketone -ketone (PEKK) secondary crowns for 2-implant retained mandibular complete overdentures.</p><p><strong>Materials and methods: </strong>Ten healthy completely edentulous patients aged 55-60 years were selected for this study. Each patient received two implants in the mandibular canine regions. Maxillary conventional complete dentures were constructed against implant-retained mandibular overdentures for all patients. Zirconia- PEKK telescopic attachments were fabricated to retain the overdentures where primary copings were constructed of zirconia and secondary ones were constructed of PEKK. Retention force and surface wear were evaluated at the time of overdenture insertion (T0), and after 6 months of overdenture use (T6).</p><p><strong>Results: </strong>The results revealed less wear of zirconia copings compared to PEKK ones at T0 and T6. However, both materials showed insignificant wear after 6 months of overdenture use. A significant increase in retention force was observed after 6 months of overdenture use.</p><p><strong>Conclusion: </strong>Within limitations of this study, PEKK may be considered a promising alternative material for telescopic secondary crowns construction combined to zirconia primary ones, regarding the wear resistance and the satisfactory retention forces.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":" ","pages":"20-27"},"PeriodicalIF":1.1000,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Surface Wear and Retention Force of Zirconia and PEKK Implant-retained Crowns.\",\"authors\":\"R M K Emera, O Askar\",\"doi\":\"10.1922/EJPRD_2524Emera08\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of this study was to evaluate the surface wear and retention force of telescopic attachments made of zirconia primary crowns and poly-ether- ketone -ketone (PEKK) secondary crowns for 2-implant retained mandibular complete overdentures.</p><p><strong>Materials and methods: </strong>Ten healthy completely edentulous patients aged 55-60 years were selected for this study. Each patient received two implants in the mandibular canine regions. Maxillary conventional complete dentures were constructed against implant-retained mandibular overdentures for all patients. Zirconia- PEKK telescopic attachments were fabricated to retain the overdentures where primary copings were constructed of zirconia and secondary ones were constructed of PEKK. Retention force and surface wear were evaluated at the time of overdenture insertion (T0), and after 6 months of overdenture use (T6).</p><p><strong>Results: </strong>The results revealed less wear of zirconia copings compared to PEKK ones at T0 and T6. However, both materials showed insignificant wear after 6 months of overdenture use. A significant increase in retention force was observed after 6 months of overdenture use.</p><p><strong>Conclusion: </strong>Within limitations of this study, PEKK may be considered a promising alternative material for telescopic secondary crowns construction combined to zirconia primary ones, regarding the wear resistance and the satisfactory retention forces.</p>\",\"PeriodicalId\":45686,\"journal\":{\"name\":\"European Journal of Prosthodontics and Restorative Dentistry\",\"volume\":\" \",\"pages\":\"20-27\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-02-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Prosthodontics and Restorative Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1922/EJPRD_2524Emera08\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Prosthodontics and Restorative Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1922/EJPRD_2524Emera08","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在评估氧化锆主冠和聚醚酮(PEKK)次冠制成的伸缩式附着体的表面磨损和固位力,用于双种植体固位的下颌全覆盖义齿:本研究选择了 10 名 55-60 岁的健康全口无牙患者。每位患者都在下颌犬齿区植入了两颗种植体。所有患者的上颌传统全口义齿与种植体固位的下颌覆盖义齿均已制作完成。为固位覆盖义齿,制作了氧化锆-PEKK伸缩式连接体,其中主连接体由氧化锆制成,副连接体由PEKK制成。对安装覆盖义齿时(T0)和使用覆盖义齿 6 个月后(T6)的固位力和表面磨损情况进行了评估:结果显示,在 T0 和 T6 阶段,氧化锆义齿的磨损程度低于 PEKK 义齿。然而,在覆盖义齿使用 6 个月后,两种材料的磨损都不明显。结论:在本研究的限制条件下,PEKK 在耐磨性和令人满意的固位力方面,可以被认为是与氧化锆基底冠结合使用的伸缩式基底冠的理想替代材料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Surface Wear and Retention Force of Zirconia and PEKK Implant-retained Crowns.

Purpose: The aim of this study was to evaluate the surface wear and retention force of telescopic attachments made of zirconia primary crowns and poly-ether- ketone -ketone (PEKK) secondary crowns for 2-implant retained mandibular complete overdentures.

Materials and methods: Ten healthy completely edentulous patients aged 55-60 years were selected for this study. Each patient received two implants in the mandibular canine regions. Maxillary conventional complete dentures were constructed against implant-retained mandibular overdentures for all patients. Zirconia- PEKK telescopic attachments were fabricated to retain the overdentures where primary copings were constructed of zirconia and secondary ones were constructed of PEKK. Retention force and surface wear were evaluated at the time of overdenture insertion (T0), and after 6 months of overdenture use (T6).

Results: The results revealed less wear of zirconia copings compared to PEKK ones at T0 and T6. However, both materials showed insignificant wear after 6 months of overdenture use. A significant increase in retention force was observed after 6 months of overdenture use.

Conclusion: Within limitations of this study, PEKK may be considered a promising alternative material for telescopic secondary crowns construction combined to zirconia primary ones, regarding the wear resistance and the satisfactory retention forces.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.30
自引率
7.70%
发文量
0
期刊介绍: The European Journal of Prosthodontics and Restorative Dentistry is published quarterly and includes clinical and research articles in subjects such as prosthodontics, operative dentistry, implantology, endodontics, periodontics and dental materials.
期刊最新文献
Influence of Surface Roughness on the Adhesion of Hydroxyapatite Coatings to Titanium and Titanium Alloy Surfaces: A Systematic Review of in vitro Experimental Studies. Performance of Fiberglass Posts Versus Fiber- Reinforced Resin Composites in Endodontically Treated Anterior Teeth Without Ferrule: A Systematic Review. Assessment of Efficacy of Implant Screwdrivers' During Multiple Tightening/ Untightening Cycles. An in vitro Study. Hybrid Full-Arch Rehabilitation Using Conventional And Zygomatic Implants: A Short-Term Retrospective Analysis. Clinical Survival of Indirect, Posterior Fiber-Reinforced Composite Fixed Dental Prosthesis: Up to 15 Years of Prospective Clinical Follow Up.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1