Gavin Rc Clark, Callum G Fraser, Judith A Strachan, Robert Jc Steele
{"title":"两年一次的以粪便免疫化学测试为基础的结直肠癌筛查计划的第二轮粪便血红蛋白浓度与第一轮结果的比较","authors":"Gavin Rc Clark, Callum G Fraser, Judith A Strachan, Robert Jc Steele","doi":"10.1177/09691413221110012","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>How faecal haemoglobin concentrations (f-Hb) vary from one round to the next in a colorectal cancer (CRC) screening programme, and relate to colonoscopy findings, are unknown. Our aim was to use data from the first two rounds of the faecal immunochemical test (FIT) based Scottish Bowel Screening Programme (SBoSP) to explore these issues.</p><p><strong>Methods: </strong>Faecal haemoglobin concentration (f-Hb) percentiles in the second round were compared with those in the first when the first round yielded a negative FIT result (<80 µg Hb/g faeces), a positive FIT but no colonoscopy, CRC, all adenoma, and a negative colonoscopy. In addition, the outcomes in the first and second rounds were compared.</p><p><strong>Results: </strong>The profiles of f-Hb in the first and second rounds differed in (a) those who had had a negative FIT result in the first round and (b) those in whom neoplastic pathology had been found. In contrast, the pattern of difference between profiles in those who had had a negative colonoscopy was very similar to that in those in whom an adenoma had been found. In addition, the risk of CRC being diagnosed in the second round after a negative colonoscopy in the first was 3.0%, not very different to that after a negative test result (4.9%).</p><p><strong>Conclusions: </strong>Adenomas may be rarely the cause of a positive FIT result. An alternative explanation as to why these are detected using FIT is required. In addition, a negative colonoscopy for a positive FIT result does not rule out the finding of significant neoplastic pathology in the next round.</p>","PeriodicalId":51089,"journal":{"name":"Journal of Medical Screening","volume":"29 4","pages":"249-254"},"PeriodicalIF":2.6000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9574424/pdf/","citationCount":"1","resultStr":"{\"title\":\"Comparison with first round findings of faecal haemoglobin concentrations and clinical outcomes in the second round of a biennial faecal immunochemical test based colorectal cancer screening programme.\",\"authors\":\"Gavin Rc Clark, Callum G Fraser, Judith A Strachan, Robert Jc Steele\",\"doi\":\"10.1177/09691413221110012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>How faecal haemoglobin concentrations (f-Hb) vary from one round to the next in a colorectal cancer (CRC) screening programme, and relate to colonoscopy findings, are unknown. Our aim was to use data from the first two rounds of the faecal immunochemical test (FIT) based Scottish Bowel Screening Programme (SBoSP) to explore these issues.</p><p><strong>Methods: </strong>Faecal haemoglobin concentration (f-Hb) percentiles in the second round were compared with those in the first when the first round yielded a negative FIT result (<80 µg Hb/g faeces), a positive FIT but no colonoscopy, CRC, all adenoma, and a negative colonoscopy. In addition, the outcomes in the first and second rounds were compared.</p><p><strong>Results: </strong>The profiles of f-Hb in the first and second rounds differed in (a) those who had had a negative FIT result in the first round and (b) those in whom neoplastic pathology had been found. In contrast, the pattern of difference between profiles in those who had had a negative colonoscopy was very similar to that in those in whom an adenoma had been found. In addition, the risk of CRC being diagnosed in the second round after a negative colonoscopy in the first was 3.0%, not very different to that after a negative test result (4.9%).</p><p><strong>Conclusions: </strong>Adenomas may be rarely the cause of a positive FIT result. An alternative explanation as to why these are detected using FIT is required. In addition, a negative colonoscopy for a positive FIT result does not rule out the finding of significant neoplastic pathology in the next round.</p>\",\"PeriodicalId\":51089,\"journal\":{\"name\":\"Journal of Medical Screening\",\"volume\":\"29 4\",\"pages\":\"249-254\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2022-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9574424/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Screening\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/09691413221110012\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Screening","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/09691413221110012","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
Comparison with first round findings of faecal haemoglobin concentrations and clinical outcomes in the second round of a biennial faecal immunochemical test based colorectal cancer screening programme.
Objective: How faecal haemoglobin concentrations (f-Hb) vary from one round to the next in a colorectal cancer (CRC) screening programme, and relate to colonoscopy findings, are unknown. Our aim was to use data from the first two rounds of the faecal immunochemical test (FIT) based Scottish Bowel Screening Programme (SBoSP) to explore these issues.
Methods: Faecal haemoglobin concentration (f-Hb) percentiles in the second round were compared with those in the first when the first round yielded a negative FIT result (<80 µg Hb/g faeces), a positive FIT but no colonoscopy, CRC, all adenoma, and a negative colonoscopy. In addition, the outcomes in the first and second rounds were compared.
Results: The profiles of f-Hb in the first and second rounds differed in (a) those who had had a negative FIT result in the first round and (b) those in whom neoplastic pathology had been found. In contrast, the pattern of difference between profiles in those who had had a negative colonoscopy was very similar to that in those in whom an adenoma had been found. In addition, the risk of CRC being diagnosed in the second round after a negative colonoscopy in the first was 3.0%, not very different to that after a negative test result (4.9%).
Conclusions: Adenomas may be rarely the cause of a positive FIT result. An alternative explanation as to why these are detected using FIT is required. In addition, a negative colonoscopy for a positive FIT result does not rule out the finding of significant neoplastic pathology in the next round.
期刊介绍:
Journal of Medical Screening, a fully peer reviewed journal, is concerned with all aspects of medical screening, particularly the publication of research that advances screening theory and practice. The journal aims to increase awareness of the principles of screening (quantitative and statistical aspects), screening techniques and procedures and methodologies from all specialties. An essential subscription for physicians, clinicians and academics with an interest in screening, epidemiology and public health.