眼生物测量综合比较:基于网络的大数据分析。

IF 5.4 3区 材料科学 Q2 CHEMISTRY, PHYSICAL ACS Applied Energy Materials Pub Date : 2022-12-10 DOI:10.1186/s40662-022-00320-3
Jinjin Yu, Daizong Wen, Jing Zhao, Yiran Wang, Ke Feng, Ting Wan, Giacomo Savini, Colm McAlinden, Xuanqiao Lin, Lingling Niu, Sisi Chen, Qingyi Gao, Rui Ning, Yili Jin, Xingtao Zhou, Jinhai Huang
{"title":"眼生物测量综合比较:基于网络的大数据分析。","authors":"Jinjin Yu,&nbsp;Daizong Wen,&nbsp;Jing Zhao,&nbsp;Yiran Wang,&nbsp;Ke Feng,&nbsp;Ting Wan,&nbsp;Giacomo Savini,&nbsp;Colm McAlinden,&nbsp;Xuanqiao Lin,&nbsp;Lingling Niu,&nbsp;Sisi Chen,&nbsp;Qingyi Gao,&nbsp;Rui Ning,&nbsp;Yili Jin,&nbsp;Xingtao Zhou,&nbsp;Jinhai Huang","doi":"10.1186/s40662-022-00320-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To systematically compare and rank ocular measurements with optical and ultrasound biometers based on big data.</p><p><strong>Methods: </strong>PubMed, Embase, the Cochrane Library and the US trial registry ( www.</p><p><strong>Clinicaltrial: </strong>gov ) were used to systematically search trials published up to October 22nd, 2020. We included comparative studies reporting the following parameters measured by at least two devices: axial length (AL), flattest meridian keratometry (Kf), steepest meridian keratometry (Ks), mean keratometry (Km), astigmatism (AST), astigmatism vectors J<sub>0</sub> and J<sub>45</sub>, anterior chamber depth (ACD), aqueous depth (AQD), central corneal thickness (CCT), corneal diameter (CD) and lens thickness (LT). A network-based big data analysis was conducted using STATA version 13.1.</p><p><strong>Results: </strong>Across 129 studies involving 17,181 eyes, 12 optical biometers and two ultrasound biometers (with both contact and immersion techniques) were identified. A network meta-analysis for AL and ACD measurements found that statistically significant differences existed when contact ultrasound biometry was compared with the optical biometers. There were no statistically significant differences among the four swept-source optical coherence tomography (SS-OCT) based devices (IOLMaster 700, OA-2000, Argos and ANTERION). As for Ks, Km and CD, statistically significant differences were found when the Pentacam AXL was compared with the IOLMaster and IOLMaster 500. There were statistically significant differences for CCT when the OA-2000 was compared to Pentacam AXL, IOLMaster 700, Lenstar, AL-Scan and Galilei G6.</p><p><strong>Conclusion: </strong>For AL and ACD, contact ultrasound biometry obtains the lower values compared with optical biometers. The Pentacam AXL achieves the lowest values for keratometry and CD. The smallest value for CCT measurement is found with the OA-2000.</p>","PeriodicalId":4,"journal":{"name":"ACS Applied Energy Materials","volume":null,"pages":null},"PeriodicalIF":5.4000,"publicationDate":"2022-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9808957/pdf/","citationCount":"6","resultStr":"{\"title\":\"Comprehensive comparisons of ocular biometry: A network-based big data analysis.\",\"authors\":\"Jinjin Yu,&nbsp;Daizong Wen,&nbsp;Jing Zhao,&nbsp;Yiran Wang,&nbsp;Ke Feng,&nbsp;Ting Wan,&nbsp;Giacomo Savini,&nbsp;Colm McAlinden,&nbsp;Xuanqiao Lin,&nbsp;Lingling Niu,&nbsp;Sisi Chen,&nbsp;Qingyi Gao,&nbsp;Rui Ning,&nbsp;Yili Jin,&nbsp;Xingtao Zhou,&nbsp;Jinhai Huang\",\"doi\":\"10.1186/s40662-022-00320-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To systematically compare and rank ocular measurements with optical and ultrasound biometers based on big data.</p><p><strong>Methods: </strong>PubMed, Embase, the Cochrane Library and the US trial registry ( www.</p><p><strong>Clinicaltrial: </strong>gov ) were used to systematically search trials published up to October 22nd, 2020. We included comparative studies reporting the following parameters measured by at least two devices: axial length (AL), flattest meridian keratometry (Kf), steepest meridian keratometry (Ks), mean keratometry (Km), astigmatism (AST), astigmatism vectors J<sub>0</sub> and J<sub>45</sub>, anterior chamber depth (ACD), aqueous depth (AQD), central corneal thickness (CCT), corneal diameter (CD) and lens thickness (LT). A network-based big data analysis was conducted using STATA version 13.1.</p><p><strong>Results: </strong>Across 129 studies involving 17,181 eyes, 12 optical biometers and two ultrasound biometers (with both contact and immersion techniques) were identified. A network meta-analysis for AL and ACD measurements found that statistically significant differences existed when contact ultrasound biometry was compared with the optical biometers. There were no statistically significant differences among the four swept-source optical coherence tomography (SS-OCT) based devices (IOLMaster 700, OA-2000, Argos and ANTERION). As for Ks, Km and CD, statistically significant differences were found when the Pentacam AXL was compared with the IOLMaster and IOLMaster 500. There were statistically significant differences for CCT when the OA-2000 was compared to Pentacam AXL, IOLMaster 700, Lenstar, AL-Scan and Galilei G6.</p><p><strong>Conclusion: </strong>For AL and ACD, contact ultrasound biometry obtains the lower values compared with optical biometers. The Pentacam AXL achieves the lowest values for keratometry and CD. The smallest value for CCT measurement is found with the OA-2000.</p>\",\"PeriodicalId\":4,\"journal\":{\"name\":\"ACS Applied Energy Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.4000,\"publicationDate\":\"2022-12-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9808957/pdf/\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Energy Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40662-022-00320-3\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, PHYSICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Energy Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40662-022-00320-3","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 6

摘要

目的:对基于大数据的光学和超声生物仪进行眼部测量的系统比较和排序。方法:使用PubMed、Embase、Cochrane图书馆和美国试验注册中心(www.Clinicaltrial: gov)系统检索截至2020年10月22日发表的试验。我们纳入了用至少两种仪器测量以下参数的比较研究:轴长(AL)、最平坦子午角度数(Kf)、最陡子午角度数(Ks)、平均角度数(Km)、散光(AST)、散光矢量J0和J45、前房深度(ACD)、水深(AQD)、角膜中央厚度(CCT)、角膜直径(CD)和晶状体厚度(LT)。使用STATA 13.1版本进行基于网络的大数据分析。结果:在涉及17,181只眼睛的129项研究中,确定了12个光学生物计和2个超声波生物计(包括接触和浸入技术)。一项针对AL和ACD测量的网络荟萃分析发现,接触超声生物测量与光学生物测量相比存在统计学显著差异。四种扫描源光学相干层析成像(SS-OCT)设备(IOLMaster 700、OA-2000、Argos和ANTERION)之间的差异无统计学意义。Pentacam AXL与IOLMaster、IOLMaster 500比较,k、Km、CD差异有统计学意义。OA-2000与Pentacam AXL、IOLMaster 700、Lenstar、AL-Scan和Galilei G6的CCT比较,差异有统计学意义。结论:对于AL和ACD,接触式超声生物测量比光学生物测量获得更低的测量值。Pentacam AXL在角膜测量和CD测量中达到最低值。在CCT测量中,OA-2000达到最低值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comprehensive comparisons of ocular biometry: A network-based big data analysis.

Purpose: To systematically compare and rank ocular measurements with optical and ultrasound biometers based on big data.

Methods: PubMed, Embase, the Cochrane Library and the US trial registry ( www.

Clinicaltrial: gov ) were used to systematically search trials published up to October 22nd, 2020. We included comparative studies reporting the following parameters measured by at least two devices: axial length (AL), flattest meridian keratometry (Kf), steepest meridian keratometry (Ks), mean keratometry (Km), astigmatism (AST), astigmatism vectors J0 and J45, anterior chamber depth (ACD), aqueous depth (AQD), central corneal thickness (CCT), corneal diameter (CD) and lens thickness (LT). A network-based big data analysis was conducted using STATA version 13.1.

Results: Across 129 studies involving 17,181 eyes, 12 optical biometers and two ultrasound biometers (with both contact and immersion techniques) were identified. A network meta-analysis for AL and ACD measurements found that statistically significant differences existed when contact ultrasound biometry was compared with the optical biometers. There were no statistically significant differences among the four swept-source optical coherence tomography (SS-OCT) based devices (IOLMaster 700, OA-2000, Argos and ANTERION). As for Ks, Km and CD, statistically significant differences were found when the Pentacam AXL was compared with the IOLMaster and IOLMaster 500. There were statistically significant differences for CCT when the OA-2000 was compared to Pentacam AXL, IOLMaster 700, Lenstar, AL-Scan and Galilei G6.

Conclusion: For AL and ACD, contact ultrasound biometry obtains the lower values compared with optical biometers. The Pentacam AXL achieves the lowest values for keratometry and CD. The smallest value for CCT measurement is found with the OA-2000.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Energy Materials
ACS Applied Energy Materials Materials Science-Materials Chemistry
CiteScore
10.30
自引率
6.20%
发文量
1368
期刊介绍: ACS Applied Energy Materials is an interdisciplinary journal publishing original research covering all aspects of materials, engineering, chemistry, physics and biology relevant to energy conversion and storage. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrate knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important energy applications.
期刊最新文献
Red ginseng polysaccharide promotes ferroptosis in gastric cancer cells by inhibiting PI3K/Akt pathway through down-regulation of AQP3. Diagnostic value of 18F-PSMA-1007 PET/CT for predicting the pathological grade of prostate cancer. Correction. Wilms' tumor 1 -targeting cancer vaccine: Recent advancements and future perspectives. Toll-like receptor agonists as cancer vaccine adjuvants.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1