{"title":"脊柱内固定后金属松动伴脊柱植入物松动1例报告。","authors":"Yiu Hin Kwan,&nbsp;Hong Lee Terry Teo,&nbsp;Shree Kumar Dinesh,&nbsp;Wee Lim Loo","doi":"10.5312/wjo.v14.i8.651","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Spinal metallosis is a rare complication following spinal instrumentation whereby an inflammatory response to the metal implants results in the development of granulomatous tissue.</p><p><strong>Case summary: </strong>We describe the case of a 78-year-old woman who had recurrence of back pain 5 years after lumbar spine posterior decompression and instrumented fusion. Lumbar spine radiographs showed hardware loosening and magnetic resonance imaging showed adjacent segment disease. Revision surgery revealed evidence of metallosis intraoperatively.</p><p><strong>Conclusion: </strong>Spinal metallosis can present several years after instrumentation. Radiography and computed tomography may demonstrate hardware loosening secondary to metallosis. Blood metal concentrations associated with spinal metallosis have yet to be established. Hence, metallosis is still an intraoperative and histopathological diagnosis. The presence of metallosis after spinal instrumentation likely indicates a more complex underlying problem: Pseudarthrosis, failure to address sagittal balance, infection, and cross-threading of set screws. Hence, identifying metallosis is important, but initiating treatment promptly for symptomatic implant loosening is of greater paramount.</p>","PeriodicalId":47843,"journal":{"name":"World Journal of Orthopedics","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2023-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/93/dd/WJO-14-651.PMC10473909.pdf","citationCount":"0","resultStr":"{\"title\":\"Metallosis with spinal implant loosening after spinal instrumentation: A case report.\",\"authors\":\"Yiu Hin Kwan,&nbsp;Hong Lee Terry Teo,&nbsp;Shree Kumar Dinesh,&nbsp;Wee Lim Loo\",\"doi\":\"10.5312/wjo.v14.i8.651\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Spinal metallosis is a rare complication following spinal instrumentation whereby an inflammatory response to the metal implants results in the development of granulomatous tissue.</p><p><strong>Case summary: </strong>We describe the case of a 78-year-old woman who had recurrence of back pain 5 years after lumbar spine posterior decompression and instrumented fusion. Lumbar spine radiographs showed hardware loosening and magnetic resonance imaging showed adjacent segment disease. Revision surgery revealed evidence of metallosis intraoperatively.</p><p><strong>Conclusion: </strong>Spinal metallosis can present several years after instrumentation. Radiography and computed tomography may demonstrate hardware loosening secondary to metallosis. Blood metal concentrations associated with spinal metallosis have yet to be established. Hence, metallosis is still an intraoperative and histopathological diagnosis. The presence of metallosis after spinal instrumentation likely indicates a more complex underlying problem: Pseudarthrosis, failure to address sagittal balance, infection, and cross-threading of set screws. Hence, identifying metallosis is important, but initiating treatment promptly for symptomatic implant loosening is of greater paramount.</p>\",\"PeriodicalId\":47843,\"journal\":{\"name\":\"World Journal of Orthopedics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2023-08-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/93/dd/WJO-14-651.PMC10473909.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"World Journal of Orthopedics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5312/wjo.v14.i8.651\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Orthopedics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5312/wjo.v14.i8.651","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景:脊柱金属病是脊柱内固定术后罕见的并发症,因金属植入物引起的炎症反应导致肉芽肿组织的发展。病例总结:我们描述了一位78岁的女性,她在腰椎后路减压和内固定融合术5年后背部疼痛复发。腰椎x线片显示硬体松动,磁共振成像显示邻近节段病变。翻修手术显示术中出现金属结核。结论:脊柱金属病可在置入后数年出现。x线摄影和计算机断层扫描可显示继发于金属病的硬件松动。与脊柱金属病相关的血金属浓度尚未确定。因此,金属病仍然是术中和组织病理学诊断。脊柱内固定术后出现金属病可能表明存在更复杂的潜在问题:假关节、矢状面平衡失败、感染和固定螺钉的交叉穿线。因此,确定金属病是重要的,但对有症状的种植体松动及时开始治疗更为重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Metallosis with spinal implant loosening after spinal instrumentation: A case report.

Background: Spinal metallosis is a rare complication following spinal instrumentation whereby an inflammatory response to the metal implants results in the development of granulomatous tissue.

Case summary: We describe the case of a 78-year-old woman who had recurrence of back pain 5 years after lumbar spine posterior decompression and instrumented fusion. Lumbar spine radiographs showed hardware loosening and magnetic resonance imaging showed adjacent segment disease. Revision surgery revealed evidence of metallosis intraoperatively.

Conclusion: Spinal metallosis can present several years after instrumentation. Radiography and computed tomography may demonstrate hardware loosening secondary to metallosis. Blood metal concentrations associated with spinal metallosis have yet to be established. Hence, metallosis is still an intraoperative and histopathological diagnosis. The presence of metallosis after spinal instrumentation likely indicates a more complex underlying problem: Pseudarthrosis, failure to address sagittal balance, infection, and cross-threading of set screws. Hence, identifying metallosis is important, but initiating treatment promptly for symptomatic implant loosening is of greater paramount.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.10
自引率
0.00%
发文量
814
期刊最新文献
Application prospects of urine-derived stem cells in neurological and musculoskeletal diseases. Atypical cervical spondylotic radiculopathy resulting in a hypertensive emergency during cervical extension: A case report and review of literature. Clinical implications of reconsideration of enthesitis/enthesopathy/enthesial erosion, as tendon attachment-localized avulsions and stress fracture equivalents. Conversion hip arthroplasty for failed nailing of intertrochanteric fracture: Reflections on some important aspects. Evidence-based orthobiologic practice: Current evidence review and future directions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1