SentiMag技术定位乳腺不可触及病灶的准确性和可行性。

IF 1.3 Q3 Medicine Minerva chirurgica Pub Date : 2020-08-01 DOI:10.23736/S0026-4733.20.08303-0
Antonio Rulli, Piero Covarelli, Alessandra Servoli, Andrea Saracini, Paola Panzarola, Renato Colella, Carlo Boselli, Francesco Barberini
{"title":"SentiMag技术定位乳腺不可触及病灶的准确性和可行性。","authors":"Antonio Rulli,&nbsp;Piero Covarelli,&nbsp;Alessandra Servoli,&nbsp;Andrea Saracini,&nbsp;Paola Panzarola,&nbsp;Renato Colella,&nbsp;Carlo Boselli,&nbsp;Francesco Barberini","doi":"10.23736/S0026-4733.20.08303-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Non-palpable breast lesions are more frequent now than in the past due to the attention toward the mammary pathology and the screening diffusion; the marking of such lesions is very important for a successful surgery. The SentiMag System uses a magnetic marker that is inoculated transdermal in the breast through an 18-gauge needle.</p><p><strong>Methods: </strong>Between April 1<sup>st</sup> and June 30<sup>th</sup>, 2018, 16 patients with non-palpable breast lesions were selected and subjected to surgery using the SentiMag System in our Unit. They were women with a mean age of 52 years (range 30-84 years). Seven of 16 (43.7%) had a borderline preoperative histological or cytological diagnosis (C3/B3), and nine (56.3%) a diagnosis of carcinoma (C5/B5). Six (37.5%) were marked on ultrasound guidance and 10 (62.5%) on a mammography stereotaxic guide.</p><p><strong>Results: </strong>The time for the marker positioning ranged from 2 to 10 minutes. The radiological control of the surgical specimen always showed the presence of both the lesion and the marker, both centered within the specimen and intact. The pathology revealed seven benign lesions, one in-situ, and eight infiltrating carcinomas.</p><p><strong>Conclusions: </strong>The SentiMag represents a fast and safe preoperative marking system of non-palpable breast lesions, cutting the radio exposure for personnel and patients. The marker is not displaced over time and it is rapid to place and easy to locate intraoperatively, allowing a clear dissection plane around the lesion. Thus, this reduces the amount of gland removed, improving the aesthetic result mostly in small breasts.</p>","PeriodicalId":18714,"journal":{"name":"Minerva chirurgica","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Accuracy and feasibility of SentiMag technique for localization of non-palpable breast lesions.\",\"authors\":\"Antonio Rulli,&nbsp;Piero Covarelli,&nbsp;Alessandra Servoli,&nbsp;Andrea Saracini,&nbsp;Paola Panzarola,&nbsp;Renato Colella,&nbsp;Carlo Boselli,&nbsp;Francesco Barberini\",\"doi\":\"10.23736/S0026-4733.20.08303-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Non-palpable breast lesions are more frequent now than in the past due to the attention toward the mammary pathology and the screening diffusion; the marking of such lesions is very important for a successful surgery. The SentiMag System uses a magnetic marker that is inoculated transdermal in the breast through an 18-gauge needle.</p><p><strong>Methods: </strong>Between April 1<sup>st</sup> and June 30<sup>th</sup>, 2018, 16 patients with non-palpable breast lesions were selected and subjected to surgery using the SentiMag System in our Unit. They were women with a mean age of 52 years (range 30-84 years). Seven of 16 (43.7%) had a borderline preoperative histological or cytological diagnosis (C3/B3), and nine (56.3%) a diagnosis of carcinoma (C5/B5). Six (37.5%) were marked on ultrasound guidance and 10 (62.5%) on a mammography stereotaxic guide.</p><p><strong>Results: </strong>The time for the marker positioning ranged from 2 to 10 minutes. The radiological control of the surgical specimen always showed the presence of both the lesion and the marker, both centered within the specimen and intact. The pathology revealed seven benign lesions, one in-situ, and eight infiltrating carcinomas.</p><p><strong>Conclusions: </strong>The SentiMag represents a fast and safe preoperative marking system of non-palpable breast lesions, cutting the radio exposure for personnel and patients. The marker is not displaced over time and it is rapid to place and easy to locate intraoperatively, allowing a clear dissection plane around the lesion. Thus, this reduces the amount of gland removed, improving the aesthetic result mostly in small breasts.</p>\",\"PeriodicalId\":18714,\"journal\":{\"name\":\"Minerva chirurgica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2020-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Minerva chirurgica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23736/S0026-4733.20.08303-0\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minerva chirurgica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23736/S0026-4733.20.08303-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2

摘要

背景:由于对乳腺病理的重视和筛查扩散,乳腺不可触及病变较以往更为常见;这些病变的标记对于手术的成功是非常重要的。SentiMag系统使用一种磁性标记物,通过一根18号针头经皮注射到乳房中。方法:于2018年4月1日至6月30日,选取16例乳腺不可触及病变患者,采用我院SentiMag系统行手术治疗。她们是平均年龄52岁(30-84岁)的女性。16例患者中有7例(43.7%)术前组织学或细胞学诊断为边缘性(C3/B3), 9例(56.3%)诊断为癌(C5/B5)。超声引导标记6例(37.5%),乳房x线立体定位引导标记10例(62.5%)。结果:标记物定位时间为2 ~ 10分钟。手术标本的放射学控制总是显示病变和标记物的存在,它们都位于标本中心并且完好无损。病理显示7个良性病变,1个原位病变,8个浸润性癌。结论:SentiMag是一种快速、安全的乳腺不可触及病变术前标记系统,减少了人员和患者的放射性暴露。标记物不会随着时间的推移而移位,术中定位迅速,易于定位,在病变周围形成清晰的解剖平面。因此,这减少了切除腺体的数量,改善了小乳房的美学效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Accuracy and feasibility of SentiMag technique for localization of non-palpable breast lesions.

Background: Non-palpable breast lesions are more frequent now than in the past due to the attention toward the mammary pathology and the screening diffusion; the marking of such lesions is very important for a successful surgery. The SentiMag System uses a magnetic marker that is inoculated transdermal in the breast through an 18-gauge needle.

Methods: Between April 1st and June 30th, 2018, 16 patients with non-palpable breast lesions were selected and subjected to surgery using the SentiMag System in our Unit. They were women with a mean age of 52 years (range 30-84 years). Seven of 16 (43.7%) had a borderline preoperative histological or cytological diagnosis (C3/B3), and nine (56.3%) a diagnosis of carcinoma (C5/B5). Six (37.5%) were marked on ultrasound guidance and 10 (62.5%) on a mammography stereotaxic guide.

Results: The time for the marker positioning ranged from 2 to 10 minutes. The radiological control of the surgical specimen always showed the presence of both the lesion and the marker, both centered within the specimen and intact. The pathology revealed seven benign lesions, one in-situ, and eight infiltrating carcinomas.

Conclusions: The SentiMag represents a fast and safe preoperative marking system of non-palpable breast lesions, cutting the radio exposure for personnel and patients. The marker is not displaced over time and it is rapid to place and easy to locate intraoperatively, allowing a clear dissection plane around the lesion. Thus, this reduces the amount of gland removed, improving the aesthetic result mostly in small breasts.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Minerva chirurgica
Minerva chirurgica 医学-外科
CiteScore
1.40
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊介绍: Minerva Chirurgica publishes scientific papers on surgery. Manuscripts may be submitted in the form of editorials, original articles, review articles, case reports, special articles, letters to the Editor and guidelines. The journal aims to provide its readers with papers of the highest quality and impact through a process of careful peer review and editorial work.
期刊最新文献
Evaluation of clinical efficacy of suture-fixation mucopexy in the treatment of prolapsed hemorrhoid. Bottom-up suprapubic approach for robotic right colectomy: technical aspects and preliminary outcomes. Orthotopic liver transplantation for patients with end-stage alcohol-related liver disease and severe acute alcohol-related hepatitis: a concise review. Risk of anastomotic bleeding after left colectomy with preservation of inferior mesenteric artery for diverticular disease: preliminary results. Management of intra- and post-operative complications during TEM/TAMIS procedures. A systematic review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1