后萎缩下颌骨再生失败后放置超短(4毫米)种植体:一项回顾性研究。

Carlo Barausse, Andrea Ravidà, Lorenzo Bonifazi, Roberto Pistilli, Muhammad H A Saleh, Roberta Gasparro, Gilberto Sammartino, Hom-Lay Wang, Pietro Felice
{"title":"后萎缩下颌骨再生失败后放置超短(4毫米)种植体:一项回顾性研究。","authors":"Carlo Barausse,&nbsp;Andrea Ravidà,&nbsp;Lorenzo Bonifazi,&nbsp;Roberto Pistilli,&nbsp;Muhammad H A Saleh,&nbsp;Roberta Gasparro,&nbsp;Gilberto Sammartino,&nbsp;Hom-Lay Wang,&nbsp;Pietro Felice","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To explore whether extra-short (4-mm) implants could be used to rehabilitate sites where regenerative procedures had failed in order to avoid additional bone grafting.</p><p><strong>Materials and methods: </strong>A retrospective study was conducted among patients who had received extra-short implants after failed regenerative procedures in the posterior atrophic mandible. The research outcomes were complications, implant failure and peri-implant marginal bone loss.</p><p><strong>Results: </strong>The study population was composed of 35 patients with 103 extra-short implants placed after the failure of different reconstructive approaches. The mean follow-up duration was 41.3 ± 21.4 months post-loading. Two implants failed, leading to a failure rate of 1.94% (95% confidence interval 0.24%-6.84%) and an implant survival rate of 98.06%. The mean amount of marginal bone loss at 5 years post-loading was 0.32 ± 0.32 mm. It was significantly lower in extra-short implants placed in regenerative sites that had previously received a loaded long implant (P = 0.004). Failure of guided bone regeneration before placement of short implants tended to lead to the highest annual rate of marginal bone loss (P = 0.089). The overall rate of biological and prosthetic complications was 6.79% (95% confidence interval 1.94%-11.70%) and 3.88% (95% confidence interval 1.07%-9.65%), respectively. The success rate was 86.4% (95% confidence interval 65.10%-97.10%) after 5 years of loading.</p><p><strong>Conclusions: </strong>Within the limitations of this study, extra-short implants seem to be a good clinical option to manage reconstructive surgical failures, reducing surgical invasiveness and rehabilitation time.</p>","PeriodicalId":73463,"journal":{"name":"International journal of oral implantology (Berlin, Germany)","volume":"16 1","pages":"31-38"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Extra-short (4-mm) implants placed after regenerative failures in the posterior atrophic mandible: A retrospective study.\",\"authors\":\"Carlo Barausse,&nbsp;Andrea Ravidà,&nbsp;Lorenzo Bonifazi,&nbsp;Roberto Pistilli,&nbsp;Muhammad H A Saleh,&nbsp;Roberta Gasparro,&nbsp;Gilberto Sammartino,&nbsp;Hom-Lay Wang,&nbsp;Pietro Felice\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To explore whether extra-short (4-mm) implants could be used to rehabilitate sites where regenerative procedures had failed in order to avoid additional bone grafting.</p><p><strong>Materials and methods: </strong>A retrospective study was conducted among patients who had received extra-short implants after failed regenerative procedures in the posterior atrophic mandible. The research outcomes were complications, implant failure and peri-implant marginal bone loss.</p><p><strong>Results: </strong>The study population was composed of 35 patients with 103 extra-short implants placed after the failure of different reconstructive approaches. The mean follow-up duration was 41.3 ± 21.4 months post-loading. Two implants failed, leading to a failure rate of 1.94% (95% confidence interval 0.24%-6.84%) and an implant survival rate of 98.06%. The mean amount of marginal bone loss at 5 years post-loading was 0.32 ± 0.32 mm. It was significantly lower in extra-short implants placed in regenerative sites that had previously received a loaded long implant (P = 0.004). Failure of guided bone regeneration before placement of short implants tended to lead to the highest annual rate of marginal bone loss (P = 0.089). The overall rate of biological and prosthetic complications was 6.79% (95% confidence interval 1.94%-11.70%) and 3.88% (95% confidence interval 1.07%-9.65%), respectively. The success rate was 86.4% (95% confidence interval 65.10%-97.10%) after 5 years of loading.</p><p><strong>Conclusions: </strong>Within the limitations of this study, extra-short implants seem to be a good clinical option to manage reconstructive surgical failures, reducing surgical invasiveness and rehabilitation time.</p>\",\"PeriodicalId\":73463,\"journal\":{\"name\":\"International journal of oral implantology (Berlin, Germany)\",\"volume\":\"16 1\",\"pages\":\"31-38\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of oral implantology (Berlin, Germany)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of oral implantology (Berlin, Germany)","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨超短(4毫米)种植体是否可以用于修复再生手术失败的部位,以避免额外的植骨。材料和方法:对后侧萎缩下颌骨再生手术失败后接受超短种植体的患者进行回顾性研究。研究结果为并发症、种植体失败和种植体周围边缘骨丢失。结果:研究人群由35例患者组成,在不同的重建入路失败后放置103个超短种植体。平均随访时间为41.3±21.4个月。2例种植体失败,失败率为1.94%(95%可信区间0.24% ~ 6.84%),种植体成活率为98.06%。加载后5年的平均边缘骨丢失量为0.32±0.32 mm。在再生部位放置超短种植体,而之前接受了加载的长种植体,则显著降低(P = 0.004)。在植入短种植体之前引导骨再生失败往往导致最高的年边际骨损失率(P = 0.089)。生物并发症和假体并发症的总发生率分别为6.79%(95%可信区间1.94% ~ 11.70%)和3.88%(95%可信区间1.07% ~ 9.65%)。加载5年后,成功率为86.4%(95%置信区间65.10% ~ 97.10%)。结论:在本研究的限制下,超短种植体似乎是一种很好的临床选择,可以处理重建手术失败,减少手术侵入性和康复时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Extra-short (4-mm) implants placed after regenerative failures in the posterior atrophic mandible: A retrospective study.

Purpose: To explore whether extra-short (4-mm) implants could be used to rehabilitate sites where regenerative procedures had failed in order to avoid additional bone grafting.

Materials and methods: A retrospective study was conducted among patients who had received extra-short implants after failed regenerative procedures in the posterior atrophic mandible. The research outcomes were complications, implant failure and peri-implant marginal bone loss.

Results: The study population was composed of 35 patients with 103 extra-short implants placed after the failure of different reconstructive approaches. The mean follow-up duration was 41.3 ± 21.4 months post-loading. Two implants failed, leading to a failure rate of 1.94% (95% confidence interval 0.24%-6.84%) and an implant survival rate of 98.06%. The mean amount of marginal bone loss at 5 years post-loading was 0.32 ± 0.32 mm. It was significantly lower in extra-short implants placed in regenerative sites that had previously received a loaded long implant (P = 0.004). Failure of guided bone regeneration before placement of short implants tended to lead to the highest annual rate of marginal bone loss (P = 0.089). The overall rate of biological and prosthetic complications was 6.79% (95% confidence interval 1.94%-11.70%) and 3.88% (95% confidence interval 1.07%-9.65%), respectively. The success rate was 86.4% (95% confidence interval 65.10%-97.10%) after 5 years of loading.

Conclusions: Within the limitations of this study, extra-short implants seem to be a good clinical option to manage reconstructive surgical failures, reducing surgical invasiveness and rehabilitation time.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Dental implants versus removable prostheses for the management of edentulous sites in patients with florid cemento-osseous dysplasia: A systematic review of literature with a follow-up period of at least 3 years. Effect of the mesiodistal cantilever on implant-supported single crowns on biological and technical complications: A retrospective study. Setting up our patients' dental implants for long-term success. Submerged vertical bone augmentation of supraosseous peri-implant defects. The adjunctive use of systemic antibiotics in the non-surgical and surgical treatment of peri-implantitis: A systematic review and meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1