L Pfeiferova, M Safarikova, J Ulrych, Z Krska, V Frankova, T Zima, M Kalousova
{"title":"液体活检循环无细胞DNA提取用于癌症研究。","authors":"L Pfeiferova, M Safarikova, J Ulrych, Z Krska, V Frankova, T Zima, M Kalousova","doi":"10.14712/fb2022068040153","DOIUrl":null,"url":null,"abstract":"<p><p>As the number of cancer patients globally increases, a need for reliable biomarkers including circulating tumour DNA from liquid biopsy for diagnosis, prognosis and monitoring of the disease is rising. Currently, mainly tissue samples from biopsy are used, but there are certain limitations: firstly, it is an invasive technique, and secondly, in some cases it is almost impossible to obtain an acceptable tissue sample. This could be changed by using circulating cell-free DNA from liquid biopsy, which also gives the possibility of repeated examination. Here, we focus on the options of isolating circulating cell-free DNA from plasma samples using two isolation techniques: precision manual QIAamp Circulating Nucleic Acid Kit and automatic MagNA Pure Compact (MPC) using Nucleic Acid Isolation Kit I. Manual extraction gave significantly better yields of circulating tumour DNA (P < 0.05). This DNA also had less contaminants (organic compounds or proteins). DNA obtained by both tested methods of isolation is suitable for subsequent molecular genetic methods.</p>","PeriodicalId":12281,"journal":{"name":"Folia Biologica","volume":"68 4","pages":"153-157"},"PeriodicalIF":1.1000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Circulating Cell-Free DNA Extraction from Liquid Biopsy for Cancer Research.\",\"authors\":\"L Pfeiferova, M Safarikova, J Ulrych, Z Krska, V Frankova, T Zima, M Kalousova\",\"doi\":\"10.14712/fb2022068040153\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>As the number of cancer patients globally increases, a need for reliable biomarkers including circulating tumour DNA from liquid biopsy for diagnosis, prognosis and monitoring of the disease is rising. Currently, mainly tissue samples from biopsy are used, but there are certain limitations: firstly, it is an invasive technique, and secondly, in some cases it is almost impossible to obtain an acceptable tissue sample. This could be changed by using circulating cell-free DNA from liquid biopsy, which also gives the possibility of repeated examination. Here, we focus on the options of isolating circulating cell-free DNA from plasma samples using two isolation techniques: precision manual QIAamp Circulating Nucleic Acid Kit and automatic MagNA Pure Compact (MPC) using Nucleic Acid Isolation Kit I. Manual extraction gave significantly better yields of circulating tumour DNA (P < 0.05). This DNA also had less contaminants (organic compounds or proteins). DNA obtained by both tested methods of isolation is suitable for subsequent molecular genetic methods.</p>\",\"PeriodicalId\":12281,\"journal\":{\"name\":\"Folia Biologica\",\"volume\":\"68 4\",\"pages\":\"153-157\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Folia Biologica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.14712/fb2022068040153\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Folia Biologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.14712/fb2022068040153","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOLOGY","Score":null,"Total":0}
Circulating Cell-Free DNA Extraction from Liquid Biopsy for Cancer Research.
As the number of cancer patients globally increases, a need for reliable biomarkers including circulating tumour DNA from liquid biopsy for diagnosis, prognosis and monitoring of the disease is rising. Currently, mainly tissue samples from biopsy are used, but there are certain limitations: firstly, it is an invasive technique, and secondly, in some cases it is almost impossible to obtain an acceptable tissue sample. This could be changed by using circulating cell-free DNA from liquid biopsy, which also gives the possibility of repeated examination. Here, we focus on the options of isolating circulating cell-free DNA from plasma samples using two isolation techniques: precision manual QIAamp Circulating Nucleic Acid Kit and automatic MagNA Pure Compact (MPC) using Nucleic Acid Isolation Kit I. Manual extraction gave significantly better yields of circulating tumour DNA (P < 0.05). This DNA also had less contaminants (organic compounds or proteins). DNA obtained by both tested methods of isolation is suitable for subsequent molecular genetic methods.
期刊介绍:
Journal of Cellular and Molecular Biology publishes articles describing original research aimed at the elucidation of a wide range of questions of biology and medicine at the cellular and molecular levels. Studies on all organisms as well as on human cells and tissues are welcome.