三相电流源感应加热系统电能质量的改进

A. Namadmalan, S. Fathi, J. Moghani, S. Sadeghi
{"title":"三相电流源感应加热系统电能质量的改进","authors":"A. Namadmalan, S. Fathi, J. Moghani, S. Sadeghi","doi":"10.1109/ICIEA.2011.5976028","DOIUrl":null,"url":null,"abstract":"With the increasing application of Induction Heating (IH) systems in various industries such as metallurgy, concerns about the harmonic effects and power quality of the power grid have been involved in the problems facing network operation engineers. This paper presents two methods to improve the power quality of three phase current source induction system. The two methods are active and passive solutions. One of the most important problem for current source IH systems is the start-up problem, which causes flicker at the PCC. For three-phase current source IH system an active solution with shunt active power filter and a passive solution with single tuned passive filters is used to improve harmonic distortions and sag voltages. In this paper the current source induction heating system is modeled and the transient and steady state behaviors of the system are simulated.","PeriodicalId":304500,"journal":{"name":"2011 6th IEEE Conference on Industrial Electronics and Applications","volume":"90 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Power quality improvement for three phase current source induction heating systems\",\"authors\":\"A. Namadmalan, S. Fathi, J. Moghani, S. Sadeghi\",\"doi\":\"10.1109/ICIEA.2011.5976028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the increasing application of Induction Heating (IH) systems in various industries such as metallurgy, concerns about the harmonic effects and power quality of the power grid have been involved in the problems facing network operation engineers. This paper presents two methods to improve the power quality of three phase current source induction system. The two methods are active and passive solutions. One of the most important problem for current source IH systems is the start-up problem, which causes flicker at the PCC. For three-phase current source IH system an active solution with shunt active power filter and a passive solution with single tuned passive filters is used to improve harmonic distortions and sag voltages. In this paper the current source induction heating system is modeled and the transient and steady state behaviors of the system are simulated.\",\"PeriodicalId\":304500,\"journal\":{\"name\":\"2011 6th IEEE Conference on Industrial Electronics and Applications\",\"volume\":\"90 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 6th IEEE Conference on Industrial Electronics and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIEA.2011.5976028\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 6th IEEE Conference on Industrial Electronics and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEA.2011.5976028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

随着感应加热(IH)系统在冶金等各个行业的应用越来越广泛,电网的谐波效应和电能质量问题已成为网络运行工程师所面临的问题。本文提出了改善三相电流源感应系统电能质量的两种方法。这两种方法是主动和被动的解决方案。电流源IH系统最重要的问题之一是启动问题,它会导致PCC闪烁。对于三相电流源IH系统,采用带并联有源滤波器的有源方案和带单调谐无源滤波器的无源方案来改善谐波畸变和凹陷电压。本文建立了电流源感应加热系统的模型,并对系统的暂态和稳态行为进行了仿真。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Power quality improvement for three phase current source induction heating systems
With the increasing application of Induction Heating (IH) systems in various industries such as metallurgy, concerns about the harmonic effects and power quality of the power grid have been involved in the problems facing network operation engineers. This paper presents two methods to improve the power quality of three phase current source induction system. The two methods are active and passive solutions. One of the most important problem for current source IH systems is the start-up problem, which causes flicker at the PCC. For three-phase current source IH system an active solution with shunt active power filter and a passive solution with single tuned passive filters is used to improve harmonic distortions and sag voltages. In this paper the current source induction heating system is modeled and the transient and steady state behaviors of the system are simulated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The application of soft-switching and frequency synchronization technologies in electromagnetic heater design Modified nearest neighbor fuzzy classification algorithm for ship target recognition The HPCXFGA method of main navigation performance and structure characteristic of the high-speed monohull inland ship Transformerless high step-up DC-DC converter with Cockcroft-Walton voltage multiplier Area efficient system-on-programmable-chip design for a wireless touch-triggered machining probe
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1