影响SPD对负载有效保护距离的因素探讨

Jinliang He
{"title":"影响SPD对负载有效保护距离的因素探讨","authors":"Jinliang He","doi":"10.1109/APEMC.2015.7175369","DOIUrl":null,"url":null,"abstract":"The SPD has an effective protection distance under the condition of the specific load and the specific voltage protection level of SPD. If surge protection devices (SPDs) are installed without consideration of the distance between the SPD and the protected loads, the equipment to be protected might be damaged despite of the correct energy coordination of SPDs. The IEC estimation method for effective protection distance of SPD is too rough for the guide of SPD installation. This paper reviewed our works on the effective protection distance of SPD under different voltage protection levels and different loads. The equipment characteristics, which were simulated by loads with different impedance characteristics, have strong influence on the effective protection distance of SPD. When the maximum continuous operating voltage of the SPD is determined, the higher the voltage protection level of the SPD is, the longer its effective protection distance is. Secondly, different household appliances have very different impedance characteristics, this leads the effective protection distance of different appliance to be very different. Last, there exists a worst distance between a SPD and a protected device in a low-voltage circuit. If a protected device and a SPD are separated by this worst distance, the protected device will be subject to the most severe surge voltage.","PeriodicalId":325138,"journal":{"name":"2015 Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Discussions on factors influencing the effective protection distance of SPD to loads\",\"authors\":\"Jinliang He\",\"doi\":\"10.1109/APEMC.2015.7175369\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The SPD has an effective protection distance under the condition of the specific load and the specific voltage protection level of SPD. If surge protection devices (SPDs) are installed without consideration of the distance between the SPD and the protected loads, the equipment to be protected might be damaged despite of the correct energy coordination of SPDs. The IEC estimation method for effective protection distance of SPD is too rough for the guide of SPD installation. This paper reviewed our works on the effective protection distance of SPD under different voltage protection levels and different loads. The equipment characteristics, which were simulated by loads with different impedance characteristics, have strong influence on the effective protection distance of SPD. When the maximum continuous operating voltage of the SPD is determined, the higher the voltage protection level of the SPD is, the longer its effective protection distance is. Secondly, different household appliances have very different impedance characteristics, this leads the effective protection distance of different appliance to be very different. Last, there exists a worst distance between a SPD and a protected device in a low-voltage circuit. If a protected device and a SPD are separated by this worst distance, the protected device will be subject to the most severe surge voltage.\",\"PeriodicalId\":325138,\"journal\":{\"name\":\"2015 Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC)\",\"volume\":\"47 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEMC.2015.7175369\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEMC.2015.7175369","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

在特定负载和特定电压的情况下,防雷器具有有效的保护距离。在安装防雷装置时,如果没有考虑防雷装置与被保护负载之间的距离,即使防雷装置的能量配合正确,也有可能造成被保护设备的损坏。IEC对防雷器有效保护距离的估算方法过于粗糙,无法指导防雷器的安装。本文综述了不同电压保护等级和不同负荷下SPD有效保护距离的研究工作。不同阻抗特性负载模拟的设备特性对防雷器的有效保护距离有较大影响。在确定防雷器的最大连续工作电压时,防雷器的电压保护等级越高,其有效保护距离越长。其次,不同的家电具有非常不同的阻抗特性,这就导致了不同家电的有效保护距离有很大的不同。最后,在低压电路中,防雷器与被保护器件之间存在最坏距离。当被保护设备与防雷器之间的距离达到该最坏距离时,被保护设备承受的浪涌电压将是最严重的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Discussions on factors influencing the effective protection distance of SPD to loads
The SPD has an effective protection distance under the condition of the specific load and the specific voltage protection level of SPD. If surge protection devices (SPDs) are installed without consideration of the distance between the SPD and the protected loads, the equipment to be protected might be damaged despite of the correct energy coordination of SPDs. The IEC estimation method for effective protection distance of SPD is too rough for the guide of SPD installation. This paper reviewed our works on the effective protection distance of SPD under different voltage protection levels and different loads. The equipment characteristics, which were simulated by loads with different impedance characteristics, have strong influence on the effective protection distance of SPD. When the maximum continuous operating voltage of the SPD is determined, the higher the voltage protection level of the SPD is, the longer its effective protection distance is. Secondly, different household appliances have very different impedance characteristics, this leads the effective protection distance of different appliance to be very different. Last, there exists a worst distance between a SPD and a protected device in a low-voltage circuit. If a protected device and a SPD are separated by this worst distance, the protected device will be subject to the most severe surge voltage.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Near field measurement for EMC validation of electronics board in IMA A two-step approach for EMI evaluation of a wearable ECG Asymptotic analysis of scattering from reflectarray antennas for the near-field focused applications A collective uniform geometrical theory of diffraction ray field analysis of very long and narrow finite planar arrays The effect of magneto-dielectric absorbing coating on unsymmetrical antenna cables
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1