A. Sennaroğlu, M. Gulsoy, H. Kalaycıoğlu, N. Topaloglu, A. Kurt, A. Sennaroğlu, M. Gulsoy
{"title":"铥激光系统组织焊接:预剂量学研究","authors":"A. Sennaroğlu, M. Gulsoy, H. Kalaycıoğlu, N. Topaloglu, A. Kurt, A. Sennaroğlu, M. Gulsoy","doi":"10.1109/BIYOMUT.2009.5130347","DOIUrl":null,"url":null,"abstract":"Laser tissue welding predosimetry studies are performed on Wistar rat skin by using diode-pumped and fiber-coupled Thulium (Tm:YAP) laser system emitting at 1980-nm, which is developed for medical applications. The success of laser tissue welding at 100 mW ve 160 mW of Tm:YAP laser powers is analyzed by macroscopy and histology results. Tm:YAP laser dosimetry of 100 mW, 5 second (34,66 W/cm2) is found successful for tissue welding studies.","PeriodicalId":119026,"journal":{"name":"2009 14th National Biomedical Engineering Meeting","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Tissue welding by Thulium laser system: Predosimetry studies\",\"authors\":\"A. Sennaroğlu, M. Gulsoy, H. Kalaycıoğlu, N. Topaloglu, A. Kurt, A. Sennaroğlu, M. Gulsoy\",\"doi\":\"10.1109/BIYOMUT.2009.5130347\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Laser tissue welding predosimetry studies are performed on Wistar rat skin by using diode-pumped and fiber-coupled Thulium (Tm:YAP) laser system emitting at 1980-nm, which is developed for medical applications. The success of laser tissue welding at 100 mW ve 160 mW of Tm:YAP laser powers is analyzed by macroscopy and histology results. Tm:YAP laser dosimetry of 100 mW, 5 second (34,66 W/cm2) is found successful for tissue welding studies.\",\"PeriodicalId\":119026,\"journal\":{\"name\":\"2009 14th National Biomedical Engineering Meeting\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 14th National Biomedical Engineering Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIYOMUT.2009.5130347\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 14th National Biomedical Engineering Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIYOMUT.2009.5130347","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Tissue welding by Thulium laser system: Predosimetry studies
Laser tissue welding predosimetry studies are performed on Wistar rat skin by using diode-pumped and fiber-coupled Thulium (Tm:YAP) laser system emitting at 1980-nm, which is developed for medical applications. The success of laser tissue welding at 100 mW ve 160 mW of Tm:YAP laser powers is analyzed by macroscopy and histology results. Tm:YAP laser dosimetry of 100 mW, 5 second (34,66 W/cm2) is found successful for tissue welding studies.