{"title":"电力系统安全评估与预防控制的混合方法","authors":"K. R. Niazi, C. M. Arora, S. L. Surana","doi":"10.1109/PECON.2003.1437442","DOIUrl":null,"url":null,"abstract":"This paper presents a hybrid approach for online security evaluation and preventive control of power systems. The artificial neural network (ANN) offers potential advantages regarding efficient computation and ease of knowledge acquisition. However it is a \"black box\" type approach, which lacks interpretability. The decision tree (DT) approach is known for its interpretability but comparatively less accurate. The proposed hybrid approach combines ANN and DT approaches to exploit their potential while suppressing their drawbacks. It applies an ANN for security evaluation of power systems and DT methodology to drive preventive control measures. A divergence based feature selection algorithm has been investigated to select an optimal combination of neural training features. The method has been applied on an IEEE power system and the results obtained are promising.","PeriodicalId":136640,"journal":{"name":"Proceedings. National Power Engineering Conference, 2003. PECon 2003.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A hybrid approach for security evaluation and preventive control of power systems\",\"authors\":\"K. R. Niazi, C. M. Arora, S. L. Surana\",\"doi\":\"10.1109/PECON.2003.1437442\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a hybrid approach for online security evaluation and preventive control of power systems. The artificial neural network (ANN) offers potential advantages regarding efficient computation and ease of knowledge acquisition. However it is a \\\"black box\\\" type approach, which lacks interpretability. The decision tree (DT) approach is known for its interpretability but comparatively less accurate. The proposed hybrid approach combines ANN and DT approaches to exploit their potential while suppressing their drawbacks. It applies an ANN for security evaluation of power systems and DT methodology to drive preventive control measures. A divergence based feature selection algorithm has been investigated to select an optimal combination of neural training features. The method has been applied on an IEEE power system and the results obtained are promising.\",\"PeriodicalId\":136640,\"journal\":{\"name\":\"Proceedings. National Power Engineering Conference, 2003. PECon 2003.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings. National Power Engineering Conference, 2003. PECon 2003.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECON.2003.1437442\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. National Power Engineering Conference, 2003. PECon 2003.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECON.2003.1437442","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

提出了一种电力系统在线安全评估与预防控制的混合方法。人工神经网络在计算效率高、知识获取容易等方面具有潜在的优势。然而,它是一种“黑匣子”类型的方法,缺乏可解释性。决策树(DT)方法以其可解释性而闻名,但相对而言不太准确。所提出的混合方法结合了人工神经网络和DT方法,以利用它们的潜力,同时抑制它们的缺点。它将神经网络应用于电力系统的安全评估,并将DT方法应用于驱动预防性控制措施。研究了一种基于散度的特征选择算法,以选择神经训练特征的最优组合。该方法已应用于IEEE电力系统,取得了良好的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A hybrid approach for security evaluation and preventive control of power systems
This paper presents a hybrid approach for online security evaluation and preventive control of power systems. The artificial neural network (ANN) offers potential advantages regarding efficient computation and ease of knowledge acquisition. However it is a "black box" type approach, which lacks interpretability. The decision tree (DT) approach is known for its interpretability but comparatively less accurate. The proposed hybrid approach combines ANN and DT approaches to exploit their potential while suppressing their drawbacks. It applies an ANN for security evaluation of power systems and DT methodology to drive preventive control measures. A divergence based feature selection algorithm has been investigated to select an optimal combination of neural training features. The method has been applied on an IEEE power system and the results obtained are promising.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fabrication and testing of linear electric generator for use with a free-piston engine A hybrid approach for security evaluation and preventive control of power systems Study the effective angle of photovoltaic modules in generating an optimum energy Object oriented sparse linear solver component for power system analysis Current efforts in the management of power frequency electric and magnetic fields in Malaysia
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1