弯曲通道几何形状对雷电电磁场的影响

Xiaojia Wang, Yazhou Chen, Haojiang Wan, Lipeng Wang
{"title":"弯曲通道几何形状对雷电电磁场的影响","authors":"Xiaojia Wang, Yazhou Chen, Haojiang Wan, Lipeng Wang","doi":"10.1109/CEEM.2015.7368664","DOIUrl":null,"url":null,"abstract":"The formulas of tortuous channel lightning electromagnetic field are obtained by decomposing the current micro-source dipole and solving Maxwell's equations. The waveforms of lightning electric and magnetic fields in different areas are calculated using the transmission line model and pulse function. Then, the characteristics of lightning electromagnetic field for different channel geometries and the impact of lower section discharge channel length on electromagnetic field initial peak value are analyzed by comparing the waveforms of lightning electromagnetic fields. The results show that, the difference between the electromagnetic field waveforms of two models will decrease with the increasing of the distance and the upper section of discharge channel has little impact on electromagnetic fields in near area but the electromagnetic fields will be influenced by the upper section of discharge channel in intermediate and far field regions. Moreover, the peak value of tortuous channel lightning electromagnetic field in different field regions is mainly determined by the lower section length of the discharge channel.","PeriodicalId":442379,"journal":{"name":"2015 7th Asia-Pacific Conference on Environmental Electromagnetics (CEEM)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The influence of the tortuous channel geometry on lightning electromagnetic field\",\"authors\":\"Xiaojia Wang, Yazhou Chen, Haojiang Wan, Lipeng Wang\",\"doi\":\"10.1109/CEEM.2015.7368664\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The formulas of tortuous channel lightning electromagnetic field are obtained by decomposing the current micro-source dipole and solving Maxwell's equations. The waveforms of lightning electric and magnetic fields in different areas are calculated using the transmission line model and pulse function. Then, the characteristics of lightning electromagnetic field for different channel geometries and the impact of lower section discharge channel length on electromagnetic field initial peak value are analyzed by comparing the waveforms of lightning electromagnetic fields. The results show that, the difference between the electromagnetic field waveforms of two models will decrease with the increasing of the distance and the upper section of discharge channel has little impact on electromagnetic fields in near area but the electromagnetic fields will be influenced by the upper section of discharge channel in intermediate and far field regions. Moreover, the peak value of tortuous channel lightning electromagnetic field in different field regions is mainly determined by the lower section length of the discharge channel.\",\"PeriodicalId\":442379,\"journal\":{\"name\":\"2015 7th Asia-Pacific Conference on Environmental Electromagnetics (CEEM)\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 7th Asia-Pacific Conference on Environmental Electromagnetics (CEEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEEM.2015.7368664\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 7th Asia-Pacific Conference on Environmental Electromagnetics (CEEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEEM.2015.7368664","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

通过对电流微源偶极子进行分解,求解麦克斯韦方程组,得到了弯曲通道闪电电磁场的计算公式。利用传输线模型和脉冲函数计算了不同区域雷电电场和磁场的波形。然后,通过对雷电电磁场波形的比较,分析了不同通道几何形状下雷电电磁场的特性以及下段放电通道长度对电磁场初始峰值的影响。结果表明:两种模型的电磁场波形差值随距离的增加而减小,放电通道上半段对近场区域的电磁场影响不大,但在中、远场区域的电磁场会受到放电通道上半段的影响。不同场区弯曲通道雷电电磁场的峰值主要由放电通道的下段长度决定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The influence of the tortuous channel geometry on lightning electromagnetic field
The formulas of tortuous channel lightning electromagnetic field are obtained by decomposing the current micro-source dipole and solving Maxwell's equations. The waveforms of lightning electric and magnetic fields in different areas are calculated using the transmission line model and pulse function. Then, the characteristics of lightning electromagnetic field for different channel geometries and the impact of lower section discharge channel length on electromagnetic field initial peak value are analyzed by comparing the waveforms of lightning electromagnetic fields. The results show that, the difference between the electromagnetic field waveforms of two models will decrease with the increasing of the distance and the upper section of discharge channel has little impact on electromagnetic fields in near area but the electromagnetic fields will be influenced by the upper section of discharge channel in intermediate and far field regions. Moreover, the peak value of tortuous channel lightning electromagnetic field in different field regions is mainly determined by the lower section length of the discharge channel.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Shielding effectiveness of infinite metal plate with finite thickness at oblique incident and arbitrary polarizations Measurement uncertainty analysis of the electro-optical E-field measurement system EMP effects statistical analysis based on incident waveform characteristics Method of pulse function fitting based on the corona current measurement data A hybrid implicit-explicit FDTD method with an intermediate field
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1