{"title":"基于组织松弛特性的相位掩膜增强多回波MR图像","authors":"Taejoon Eo, Younguk Kim, Jinseong Jang, D. Hwang","doi":"10.1109/ELINFOCOM.2014.6914356","DOIUrl":null,"url":null,"abstract":"Multiple-echo magnetic resonance images are a series of images acquired at different echo times. Especially, phase images of multiple-echo images are often used to measure susceptibility of tissues. But these images tend to have a low SNR because high sampling rates are used to reduce the scan time. Conventional filters can effectively reduce noise, but introduce spatial artifacts. To obtain high-quality phase images without spatial artifacts, we developed new denoising method based on tissue relaxation properties. As a result, we could obtain high-SNR and high-resolution phase image and phase mask.","PeriodicalId":360207,"journal":{"name":"2014 International Conference on Electronics, Information and Communications (ICEIC)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Phase mask enhancement for multi-echo MR images using a novel denoising method based on tissue relaxation properties\",\"authors\":\"Taejoon Eo, Younguk Kim, Jinseong Jang, D. Hwang\",\"doi\":\"10.1109/ELINFOCOM.2014.6914356\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Multiple-echo magnetic resonance images are a series of images acquired at different echo times. Especially, phase images of multiple-echo images are often used to measure susceptibility of tissues. But these images tend to have a low SNR because high sampling rates are used to reduce the scan time. Conventional filters can effectively reduce noise, but introduce spatial artifacts. To obtain high-quality phase images without spatial artifacts, we developed new denoising method based on tissue relaxation properties. As a result, we could obtain high-SNR and high-resolution phase image and phase mask.\",\"PeriodicalId\":360207,\"journal\":{\"name\":\"2014 International Conference on Electronics, Information and Communications (ICEIC)\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Electronics, Information and Communications (ICEIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINFOCOM.2014.6914356\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Electronics, Information and Communications (ICEIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINFOCOM.2014.6914356","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Phase mask enhancement for multi-echo MR images using a novel denoising method based on tissue relaxation properties
Multiple-echo magnetic resonance images are a series of images acquired at different echo times. Especially, phase images of multiple-echo images are often used to measure susceptibility of tissues. But these images tend to have a low SNR because high sampling rates are used to reduce the scan time. Conventional filters can effectively reduce noise, but introduce spatial artifacts. To obtain high-quality phase images without spatial artifacts, we developed new denoising method based on tissue relaxation properties. As a result, we could obtain high-SNR and high-resolution phase image and phase mask.