并联有源滤波器三相级联h桥多电平逆变器的实现

N. Chellammal, Ravitheja Gurram, K. Prasad
{"title":"并联有源滤波器三相级联h桥多电平逆变器的实现","authors":"N. Chellammal, Ravitheja Gurram, K. Prasad","doi":"10.1109/ICEAS.2011.6147158","DOIUrl":null,"url":null,"abstract":"This paper presents a three-phase cascaded H-Bridge MLI as Shunt Active Filter intended for installation on industrial and utility of power distribution system is widely accepted and implemented as a solution to the power quality problems in utility, industry and commercial applications. This paper proposes the design of a shunt active power filter under the condition of voltage sag, unbalanced loads. The active power filter, which can be used under the condition of voltage sag, unbalanced or distorted source voltages, can be applicable to compensate the harmonics, reactive and negative sequence currents. The main objective of this paper is to regulate the voltage in distribution systems against any power quality issues like voltage sag, unbalancing and to reduce the harmonics using cascaded multilevel inverter as Shunt active filter.","PeriodicalId":273164,"journal":{"name":"2011 International Conference on Energy, Automation and Signal","volume":"394 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Realization of three phase cascaded H-Bridge multi-level inverter as Shunt Active Filter\",\"authors\":\"N. Chellammal, Ravitheja Gurram, K. Prasad\",\"doi\":\"10.1109/ICEAS.2011.6147158\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a three-phase cascaded H-Bridge MLI as Shunt Active Filter intended for installation on industrial and utility of power distribution system is widely accepted and implemented as a solution to the power quality problems in utility, industry and commercial applications. This paper proposes the design of a shunt active power filter under the condition of voltage sag, unbalanced loads. The active power filter, which can be used under the condition of voltage sag, unbalanced or distorted source voltages, can be applicable to compensate the harmonics, reactive and negative sequence currents. The main objective of this paper is to regulate the voltage in distribution systems against any power quality issues like voltage sag, unbalancing and to reduce the harmonics using cascaded multilevel inverter as Shunt active filter.\",\"PeriodicalId\":273164,\"journal\":{\"name\":\"2011 International Conference on Energy, Automation and Signal\",\"volume\":\"394 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Energy, Automation and Signal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEAS.2011.6147158\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Energy, Automation and Signal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEAS.2011.6147158","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文提出了一种用于工业和公用事业配电系统的三相级联h桥并联有源滤波器,作为解决公用事业、工业和商业应用中的电能质量问题的一种方法,已被广泛接受和实施。提出了一种电压暂降、负载不平衡情况下并联型有源电力滤波器的设计方法。有源滤波器可用于电压暂降、源电压不平衡或畸变等情况下,可用于补偿谐波、无功和负序电流。本文的主要目的是利用级联多电平逆变器作为并联有源滤波器来调节配电系统中的电压,以防止电压凹陷、不平衡等电能质量问题,并降低谐波。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Realization of three phase cascaded H-Bridge multi-level inverter as Shunt Active Filter
This paper presents a three-phase cascaded H-Bridge MLI as Shunt Active Filter intended for installation on industrial and utility of power distribution system is widely accepted and implemented as a solution to the power quality problems in utility, industry and commercial applications. This paper proposes the design of a shunt active power filter under the condition of voltage sag, unbalanced loads. The active power filter, which can be used under the condition of voltage sag, unbalanced or distorted source voltages, can be applicable to compensate the harmonics, reactive and negative sequence currents. The main objective of this paper is to regulate the voltage in distribution systems against any power quality issues like voltage sag, unbalancing and to reduce the harmonics using cascaded multilevel inverter as Shunt active filter.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
EQU-IITG: A multi-format formal equivalence checker Low power, dynamically reconfigurable, memoryless systolic array based architecture for Viterbi decoder Model reduction of linear interval systems using Kharitonov's polynomials An MIWO based approach of power system transient stability enhancement with STATCOM Energy efficiency invariance laws acting in the field of multiphase AC inverter drives
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1