{"title":"耳道气压对声反射阈值的影响。","authors":"S Rizzo, H J Greenberg","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This study was undertaken to investigate the effects of ear canal air pressure variation on the threshold of acoustic reflex. The acoustic reflex threshold was obtained to 500 and 1000 Hz activating signals as pressure was varied between +/- 200 mm H2O. The results demonstrated a reduction in sensitivity of the acoustic reflex with variations in positive or negative air pressure. Observation of the conductance component of admittance consistently required higher intensity levels to elicit the acoustic reflex. Clinical implications are that external air pressure can vary within a range of +/- 80 mm H2O and continue to maintain the acoustic reflex threshold close to its value obtained at maximum compliance.</p>","PeriodicalId":76027,"journal":{"name":"Journal of the American Auditory Society","volume":"5 1","pages":"21-4"},"PeriodicalIF":0.0000,"publicationDate":"1979-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of ear canal air pressure on acoustic reflex threshold.\",\"authors\":\"S Rizzo, H J Greenberg\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study was undertaken to investigate the effects of ear canal air pressure variation on the threshold of acoustic reflex. The acoustic reflex threshold was obtained to 500 and 1000 Hz activating signals as pressure was varied between +/- 200 mm H2O. The results demonstrated a reduction in sensitivity of the acoustic reflex with variations in positive or negative air pressure. Observation of the conductance component of admittance consistently required higher intensity levels to elicit the acoustic reflex. Clinical implications are that external air pressure can vary within a range of +/- 80 mm H2O and continue to maintain the acoustic reflex threshold close to its value obtained at maximum compliance.</p>\",\"PeriodicalId\":76027,\"journal\":{\"name\":\"Journal of the American Auditory Society\",\"volume\":\"5 1\",\"pages\":\"21-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1979-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Auditory Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Auditory Society","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
本研究旨在探讨耳道气压变化对声反射阈值的影响。当压力在+/- 200 mm H2O之间变化时,声反射阈值为500和1000 Hz的激活信号。结果表明,声波反射的灵敏度随着正或负气压的变化而降低。观察导纳的电导分量始终需要更高的强度水平来引起声反射。临床意义在于,外部气压可以在+/- 80mmh2o的范围内变化,并继续保持声反射阈值接近最大依从性时获得的值。
Influence of ear canal air pressure on acoustic reflex threshold.
This study was undertaken to investigate the effects of ear canal air pressure variation on the threshold of acoustic reflex. The acoustic reflex threshold was obtained to 500 and 1000 Hz activating signals as pressure was varied between +/- 200 mm H2O. The results demonstrated a reduction in sensitivity of the acoustic reflex with variations in positive or negative air pressure. Observation of the conductance component of admittance consistently required higher intensity levels to elicit the acoustic reflex. Clinical implications are that external air pressure can vary within a range of +/- 80 mm H2O and continue to maintain the acoustic reflex threshold close to its value obtained at maximum compliance.