弱电网直流储能系统功率平滑控制

Ye Zhang, Pengfei Li, Xialin Li, Zhiwang Li
{"title":"弱电网直流储能系统功率平滑控制","authors":"Ye Zhang, Pengfei Li, Xialin Li, Zhiwang Li","doi":"10.1109/ICPSAsia52756.2021.9621727","DOIUrl":null,"url":null,"abstract":"Grid-connected dc systems with high penetration of renewable power generations (RPGs) are prone to dc voltage impact and stability issues, especially when connected to a weak ac grid. In order to address these problems, a novel cascaded power and dc voltage control loops based power smoothing control for energy storage system (ESS) has been proposed in this paper. With this method, transient power fluctuations can be compensated, then transmission power of the grid-connected converter (GCC) from dc system to ac grid and dc voltage can be both smoothed. After transient power supporting, the output of ESS can be recovered according to the pre-scheduled power instruction. Moreover, a detailed small signal model of a dc system based on state-space equations has been derived for dynamic and stability analysis. Finally, the effectiveness of the proposed control method is verified by PSCAD/EMPTC based simulation results in a weak grid-connected dc system with GCC, ESS and constant power load (CPL, to simulate RPG or real loads).","PeriodicalId":296085,"journal":{"name":"2021 IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Power Smoothing Control of Energy Storage System for DC Systems Connected to Weak Grids\",\"authors\":\"Ye Zhang, Pengfei Li, Xialin Li, Zhiwang Li\",\"doi\":\"10.1109/ICPSAsia52756.2021.9621727\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Grid-connected dc systems with high penetration of renewable power generations (RPGs) are prone to dc voltage impact and stability issues, especially when connected to a weak ac grid. In order to address these problems, a novel cascaded power and dc voltage control loops based power smoothing control for energy storage system (ESS) has been proposed in this paper. With this method, transient power fluctuations can be compensated, then transmission power of the grid-connected converter (GCC) from dc system to ac grid and dc voltage can be both smoothed. After transient power supporting, the output of ESS can be recovered according to the pre-scheduled power instruction. Moreover, a detailed small signal model of a dc system based on state-space equations has been derived for dynamic and stability analysis. Finally, the effectiveness of the proposed control method is verified by PSCAD/EMPTC based simulation results in a weak grid-connected dc system with GCC, ESS and constant power load (CPL, to simulate RPG or real loads).\",\"PeriodicalId\":296085,\"journal\":{\"name\":\"2021 IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPSAsia52756.2021.9621727\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPSAsia52756.2021.9621727","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

具有高可再生能源发电(rpg)渗透率的并网直流系统容易受到直流电压影响和稳定性问题,特别是当连接到弱交流电网时。为了解决这些问题,本文提出了一种新的基于级联电源和直流电压控制回路的储能系统功率平滑控制方法。该方法可以补偿暂态功率波动,从而使并网变流器从直流系统到交流电网的传输功率和直流电压都得到平滑处理。暂态供电后,可根据预先设定的功率指令恢复ESS的输出。此外,还建立了基于状态空间方程的直流系统的详细小信号模型,用于动态和稳定性分析。最后,基于PSCAD/EMPTC的弱并网直流系统仿真结果验证了该控制方法的有效性,该系统具有GCC、ESS和恒功率负载(CPL,用于模拟RPG或实际负载)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Power Smoothing Control of Energy Storage System for DC Systems Connected to Weak Grids
Grid-connected dc systems with high penetration of renewable power generations (RPGs) are prone to dc voltage impact and stability issues, especially when connected to a weak ac grid. In order to address these problems, a novel cascaded power and dc voltage control loops based power smoothing control for energy storage system (ESS) has been proposed in this paper. With this method, transient power fluctuations can be compensated, then transmission power of the grid-connected converter (GCC) from dc system to ac grid and dc voltage can be both smoothed. After transient power supporting, the output of ESS can be recovered according to the pre-scheduled power instruction. Moreover, a detailed small signal model of a dc system based on state-space equations has been derived for dynamic and stability analysis. Finally, the effectiveness of the proposed control method is verified by PSCAD/EMPTC based simulation results in a weak grid-connected dc system with GCC, ESS and constant power load (CPL, to simulate RPG or real loads).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Simulation of No-load Medium Recovery Characteristics of CO2 Circuit Breaker The Energy Management Strategies of Residential Integrated Energy System Considering Integrated Demand Response Optimal Operation of Integrated Electricity-Gas Systems for Renewable Energy Accommodation Considering Flexible Resources Optimal Offering and Operating Strategy of CSP Plants under Different Support Mechanisms Power Loss Mitigation of Parallel-Connected Distributed Energy Resources in DC Microgrids Using a Dual-Ascent Hierarchical Control
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1