硫酸亚铁电子剂量测定法。重新评估。

H Svensson, A Brahme
{"title":"硫酸亚铁电子剂量测定法。重新评估。","authors":"H Svensson,&nbsp;A Brahme","doi":"10.3109/02841867909128219","DOIUrl":null,"url":null,"abstract":"<p><p>A theory was developed for the perturbation correction to be applied in the calorimetric determination of the ferrous sulphate dosimeter G-value. Recent determinations of the molar extinction coefficient, epsilonm, have shown that systematic errors in epsilon may have influenced experimental G-values. With precision spectrophotometers this error is cancelled in the product epsilonm.G. It was shown that after applying the perturbation correction a very small spread was obtained in calorimetric epsilonm.G-values; the standard error of the mean being 0.2 per cent. The mean G-value is 2.3 per cent lower than that recommended in ICRU Report No. 21.</p>","PeriodicalId":75417,"journal":{"name":"Acta radiologica: oncology, radiation, physics, biology","volume":"18 4","pages":"326-36"},"PeriodicalIF":0.0000,"publicationDate":"1979-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/02841867909128219","citationCount":"25","resultStr":"{\"title\":\"Ferrous sulphate dosimetry for electrons. A re-evaluation.\",\"authors\":\"H Svensson,&nbsp;A Brahme\",\"doi\":\"10.3109/02841867909128219\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A theory was developed for the perturbation correction to be applied in the calorimetric determination of the ferrous sulphate dosimeter G-value. Recent determinations of the molar extinction coefficient, epsilonm, have shown that systematic errors in epsilon may have influenced experimental G-values. With precision spectrophotometers this error is cancelled in the product epsilonm.G. It was shown that after applying the perturbation correction a very small spread was obtained in calorimetric epsilonm.G-values; the standard error of the mean being 0.2 per cent. The mean G-value is 2.3 per cent lower than that recommended in ICRU Report No. 21.</p>\",\"PeriodicalId\":75417,\"journal\":{\"name\":\"Acta radiologica: oncology, radiation, physics, biology\",\"volume\":\"18 4\",\"pages\":\"326-36\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1979-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/02841867909128219\",\"citationCount\":\"25\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta radiologica: oncology, radiation, physics, biology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/02841867909128219\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica: oncology, radiation, physics, biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/02841867909128219","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

摘要

提出了一种应用于量热法测定硫酸亚铁剂量计g值的微扰修正理论。最近对摩尔消光系数epsilonm的测定表明,epsilonm的系统误差可能会影响实验g值。使用精密分光光度计,这个误差在乘积中被抵消。结果表明,在应用微扰修正后,量热的ε - g值的分布非常小;平均值的标准误差为0.2%。平均g值比ICRU第21号报告的建议值低2.3%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ferrous sulphate dosimetry for electrons. A re-evaluation.

A theory was developed for the perturbation correction to be applied in the calorimetric determination of the ferrous sulphate dosimeter G-value. Recent determinations of the molar extinction coefficient, epsilonm, have shown that systematic errors in epsilon may have influenced experimental G-values. With precision spectrophotometers this error is cancelled in the product epsilonm.G. It was shown that after applying the perturbation correction a very small spread was obtained in calorimetric epsilonm.G-values; the standard error of the mean being 0.2 per cent. The mean G-value is 2.3 per cent lower than that recommended in ICRU Report No. 21.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Radiation sensitivity change of hemopoietic cells induced by hydroxyurea. Biliary and pancreatic secretions in abdominal irradiation. Tamoxifen treatment of advanced breast carcinoma. Effect of irradiation and chemotherapeutic agents on the capillaries of Ehrlich ascites carcinoma of mice. Comparison of various radiation techniques in treatment of the breast and chest wall.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1