变压器热模型中风扇状态不正确的检测方法

Shruti Rao, D. Tylavsky, K. Alteneder, K. Brown, Jason Gunawardena, T. LaRose
{"title":"变压器热模型中风扇状态不正确的检测方法","authors":"Shruti Rao, D. Tylavsky, K. Alteneder, K. Brown, Jason Gunawardena, T. LaRose","doi":"10.1109/NAPS.2014.6965406","DOIUrl":null,"url":null,"abstract":"Transformers are seldom loaded to their maximum capacity as per the existing industry practices. The ultimate goal of this research project is to develop a method for predicting the maximum dynamic loading capability without violating the thermal limits of the transformer's insulation. Dynamic loading must account for, at minimum, load magnitude and shape, the ambient temperature, the external cooling conditions and the thermal limits. This paper discusses methods of detecting irregularities in the cooling mode transitions for substation distribution transformers. The two HST and TOT models considered in this paper are the non-linear IEEE model and the model built using linear regression techniques.","PeriodicalId":421766,"journal":{"name":"2014 North American Power Symposium (NAPS)","volume":"340 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Methods to detect incorrect fan status for transformer thermal models\",\"authors\":\"Shruti Rao, D. Tylavsky, K. Alteneder, K. Brown, Jason Gunawardena, T. LaRose\",\"doi\":\"10.1109/NAPS.2014.6965406\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Transformers are seldom loaded to their maximum capacity as per the existing industry practices. The ultimate goal of this research project is to develop a method for predicting the maximum dynamic loading capability without violating the thermal limits of the transformer's insulation. Dynamic loading must account for, at minimum, load magnitude and shape, the ambient temperature, the external cooling conditions and the thermal limits. This paper discusses methods of detecting irregularities in the cooling mode transitions for substation distribution transformers. The two HST and TOT models considered in this paper are the non-linear IEEE model and the model built using linear regression techniques.\",\"PeriodicalId\":421766,\"journal\":{\"name\":\"2014 North American Power Symposium (NAPS)\",\"volume\":\"340 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 North American Power Symposium (NAPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAPS.2014.6965406\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 North American Power Symposium (NAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.2014.6965406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

根据现有的工业惯例,变压器很少被加载到其最大容量。本研究项目的最终目标是开发一种方法,在不违反变压器绝缘热极限的情况下预测最大动态负载能力。动态载荷至少必须考虑载荷的大小和形状、环境温度、外部冷却条件和热极限。本文讨论了变电站配电变压器冷却模式转换异常检测方法。本文考虑的两种HST和TOT模型分别是非线性IEEE模型和使用线性回归技术建立的模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Methods to detect incorrect fan status for transformer thermal models
Transformers are seldom loaded to their maximum capacity as per the existing industry practices. The ultimate goal of this research project is to develop a method for predicting the maximum dynamic loading capability without violating the thermal limits of the transformer's insulation. Dynamic loading must account for, at minimum, load magnitude and shape, the ambient temperature, the external cooling conditions and the thermal limits. This paper discusses methods of detecting irregularities in the cooling mode transitions for substation distribution transformers. The two HST and TOT models considered in this paper are the non-linear IEEE model and the model built using linear regression techniques.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Addressing cyber security for the oil, gas and energy sector Investigation of voltage stability in three-phase unbalanced distribution systems with DG using modal analysis technique Dynamic Remedial Action Scheme using online transient stability analysis Implementing a real-time cyber-physical system test bed in RTDS and OPNET Size reduction of permanent magnet generators for wind turbines with higher energy density permanent magnets
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1