振动对家兔骨骼肌血流的影响。

O Huclická, A Wright
{"title":"振动对家兔骨骼肌血流的影响。","authors":"O Huclická,&nbsp;A Wright","doi":"10.1042/cs0550471","DOIUrl":null,"url":null,"abstract":"<p><p>1. The blood flow in rabbit gastrocnemius, as measured by photoelectric drop-counter, increased when the muscle was vibrated at frequencies of 22--62 Hz. 2. Blood flow increased rapidly within 1--2 s of the start of vibration, and lasted for the whole time vibration was applied. 3. The increase in blood flow was negatively correlated with the initial blood flow, being greater with lower flows. 4. The magnitude of increase was similar in both innervated and acutely denervated muscles. 5. The arterial blood pressure did not change apart from a very brief fall at the beginning of vibration. Venous pressure rose and, consequently, the perfusion pressure was lower. The increase in blood flow thus indicates a considerable dilatation in the resistance vessels of skeletal muscle.</p>","PeriodicalId":10356,"journal":{"name":"Clinical science and molecular medicine","volume":"55 5","pages":"471-6"},"PeriodicalIF":0.0000,"publicationDate":"1978-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1042/cs0550471","citationCount":"16","resultStr":"{\"title\":\"The effect of vibration on blood flow in skeletal muscle in the rabbit.\",\"authors\":\"O Huclická,&nbsp;A Wright\",\"doi\":\"10.1042/cs0550471\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>1. The blood flow in rabbit gastrocnemius, as measured by photoelectric drop-counter, increased when the muscle was vibrated at frequencies of 22--62 Hz. 2. Blood flow increased rapidly within 1--2 s of the start of vibration, and lasted for the whole time vibration was applied. 3. The increase in blood flow was negatively correlated with the initial blood flow, being greater with lower flows. 4. The magnitude of increase was similar in both innervated and acutely denervated muscles. 5. The arterial blood pressure did not change apart from a very brief fall at the beginning of vibration. Venous pressure rose and, consequently, the perfusion pressure was lower. The increase in blood flow thus indicates a considerable dilatation in the resistance vessels of skeletal muscle.</p>\",\"PeriodicalId\":10356,\"journal\":{\"name\":\"Clinical science and molecular medicine\",\"volume\":\"55 5\",\"pages\":\"471-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1978-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1042/cs0550471\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical science and molecular medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1042/cs0550471\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical science and molecular medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1042/cs0550471","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

摘要

1. 在22 ~ 62 Hz的振动频率下,用光电滴计数仪测量家兔腓肠肌的血流量增加。在振动开始后1 ~ 2s内血流量迅速增加,并持续整个振动时间。3.血流量的增加与初始血流量呈负相关,越低血流量越大。4. 在神经支配和急性去神经支配的肌肉中,增加的幅度相似。5. 除了振动开始时的短暂下降外,动脉血压没有变化。静脉压升高,灌注压降低。因此,血流量的增加表明骨骼肌的阻力血管有相当大的扩张。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The effect of vibration on blood flow in skeletal muscle in the rabbit.

1. The blood flow in rabbit gastrocnemius, as measured by photoelectric drop-counter, increased when the muscle was vibrated at frequencies of 22--62 Hz. 2. Blood flow increased rapidly within 1--2 s of the start of vibration, and lasted for the whole time vibration was applied. 3. The increase in blood flow was negatively correlated with the initial blood flow, being greater with lower flows. 4. The magnitude of increase was similar in both innervated and acutely denervated muscles. 5. The arterial blood pressure did not change apart from a very brief fall at the beginning of vibration. Venous pressure rose and, consequently, the perfusion pressure was lower. The increase in blood flow thus indicates a considerable dilatation in the resistance vessels of skeletal muscle.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Disorders of sex development Index Acknowledgement and Disclaimer Copyright Molecular dysmorphology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1