电影透视评估Lillehei-Kaster人工心脏瓣膜的价值。

E Paquet, J Blanchette, D Desaulniers, J P Després, M Lemieux
{"title":"电影透视评估Lillehei-Kaster人工心脏瓣膜的价值。","authors":"E Paquet,&nbsp;J Blanchette,&nbsp;D Desaulniers,&nbsp;J P Després,&nbsp;M Lemieux","doi":"10.1007/BF02552048","DOIUrl":null,"url":null,"abstract":"<p><p>In order to assess the functioning of the pivoting disc of the Lillehei-Kaster prosthetic valve, a cinefluoroscopic technique using multiple angulations was developed. The disc was detected in 240 (99%) of the 242 valves studied (126 aortic, 107 mitral, and nine tricuspid valves). The maximal-opening angle of the disc was measured in 75% of the aortic but only 20% of the mitral valve prostheses in the 182 valve studies in which this was attempted. Prosthetic dysfunctions were suspected clinically in three aortic and three tricuspid valves and confirmed with the cinefluoroscopic technique. This cinefluoroscopic approach constitutes a rapid, noninvasive, and sensitive evaluation of the function of the Lillehei-Kaster prosthetic valve in the aortic position.</p>","PeriodicalId":75676,"journal":{"name":"Cardiovascular radiology","volume":"1 4","pages":"229-32"},"PeriodicalIF":0.0000,"publicationDate":"1978-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF02552048","citationCount":"0","resultStr":"{\"title\":\"Value of a cinefluoroscopic assessment of the Lillehei-Kaster prosthetic heart valves.\",\"authors\":\"E Paquet,&nbsp;J Blanchette,&nbsp;D Desaulniers,&nbsp;J P Després,&nbsp;M Lemieux\",\"doi\":\"10.1007/BF02552048\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In order to assess the functioning of the pivoting disc of the Lillehei-Kaster prosthetic valve, a cinefluoroscopic technique using multiple angulations was developed. The disc was detected in 240 (99%) of the 242 valves studied (126 aortic, 107 mitral, and nine tricuspid valves). The maximal-opening angle of the disc was measured in 75% of the aortic but only 20% of the mitral valve prostheses in the 182 valve studies in which this was attempted. Prosthetic dysfunctions were suspected clinically in three aortic and three tricuspid valves and confirmed with the cinefluoroscopic technique. This cinefluoroscopic approach constitutes a rapid, noninvasive, and sensitive evaluation of the function of the Lillehei-Kaster prosthetic valve in the aortic position.</p>\",\"PeriodicalId\":75676,\"journal\":{\"name\":\"Cardiovascular radiology\",\"volume\":\"1 4\",\"pages\":\"229-32\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1978-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/BF02552048\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular radiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/BF02552048\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/BF02552048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了评估Lillehei-Kaster假体瓣膜旋转盘的功能,我们开发了一种多角度的电影透视技术。242个瓣膜(126个主动脉瓣,107个二尖瓣和9个三尖瓣)中有240个(99%)检测到椎间盘。在182个瓣膜研究中,75%的主动脉瓣测量到了瓣的最大开口角,但只有20%的二尖瓣假体测量到了瓣的最大开口角。临床上怀疑三个主动脉瓣和三个三尖瓣的假体功能障碍,并通过电影透视技术证实。这种电影透视方法对主动脉位置的Lillehei-Kaster人工瓣膜的功能进行了快速、无创和敏感的评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Value of a cinefluoroscopic assessment of the Lillehei-Kaster prosthetic heart valves.

In order to assess the functioning of the pivoting disc of the Lillehei-Kaster prosthetic valve, a cinefluoroscopic technique using multiple angulations was developed. The disc was detected in 240 (99%) of the 242 valves studied (126 aortic, 107 mitral, and nine tricuspid valves). The maximal-opening angle of the disc was measured in 75% of the aortic but only 20% of the mitral valve prostheses in the 182 valve studies in which this was attempted. Prosthetic dysfunctions were suspected clinically in three aortic and three tricuspid valves and confirmed with the cinefluoroscopic technique. This cinefluoroscopic approach constitutes a rapid, noninvasive, and sensitive evaluation of the function of the Lillehei-Kaster prosthetic valve in the aortic position.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A note from the editors on the first anniversary of Cardiovascular Radiology Accessory blood supply to the liver from the dorsal pancreatic artery: An unusual anatomic variant Abstracts, German Society of Cardiology, Presented at the Annual Meeting, Berlin, October 27–29, 1978 A note from the editors Noninvasive perfusion control by thallium-201 myocardial scintigraphy after coronary artery bypass surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1