全身传输-发射扫描与全身相机。

Y Suzuki, H Mori, T Michigishi, K Hisada, M Matsudaira
{"title":"全身传输-发射扫描与全身相机。","authors":"Y Suzuki,&nbsp;H Mori,&nbsp;T Michigishi,&nbsp;K Hisada,&nbsp;M Matsudaira","doi":"10.2214/ajr.125.4.978","DOIUrl":null,"url":null,"abstract":"<p><p>Whole body transmission-emission scanning was carried out using a whole body camera. A disk source 30 cm in diameter filled with 99mTc was used for transmission scanning. Correct interpretation of emission scanning requires accurate anatomical orientation of the images. The value of whole body transmission-emission scanning is emphasized.</p>","PeriodicalId":22266,"journal":{"name":"The American journal of roentgenology, radium therapy, and nuclear medicine","volume":"125 4","pages":"978-80"},"PeriodicalIF":0.0000,"publicationDate":"1975-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2214/ajr.125.4.978","citationCount":"1","resultStr":"{\"title\":\"Whole body transmission-emission scanning with whole body camera.\",\"authors\":\"Y Suzuki,&nbsp;H Mori,&nbsp;T Michigishi,&nbsp;K Hisada,&nbsp;M Matsudaira\",\"doi\":\"10.2214/ajr.125.4.978\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Whole body transmission-emission scanning was carried out using a whole body camera. A disk source 30 cm in diameter filled with 99mTc was used for transmission scanning. Correct interpretation of emission scanning requires accurate anatomical orientation of the images. The value of whole body transmission-emission scanning is emphasized.</p>\",\"PeriodicalId\":22266,\"journal\":{\"name\":\"The American journal of roentgenology, radium therapy, and nuclear medicine\",\"volume\":\"125 4\",\"pages\":\"978-80\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1975-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.2214/ajr.125.4.978\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The American journal of roentgenology, radium therapy, and nuclear medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2214/ajr.125.4.978\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The American journal of roentgenology, radium therapy, and nuclear medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2214/ajr.125.4.978","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

采用全身摄像机进行全身透射-发射扫描。透射扫描采用直径30cm,填充99mTc的圆盘源。发射扫描的正确解释需要精确的图像解剖方向。强调了全身透射-发射扫描的价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Whole body transmission-emission scanning with whole body camera.

Whole body transmission-emission scanning was carried out using a whole body camera. A disk source 30 cm in diameter filled with 99mTc was used for transmission scanning. Correct interpretation of emission scanning requires accurate anatomical orientation of the images. The value of whole body transmission-emission scanning is emphasized.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The hard palate. Vesicoureteral reflux. COARCTATION of the aorta. Indications for adjunctive conservative extrafascial hysterectomy in selected cases of carcinoma of the uterine cervix. Chest roentgenography as a window to the diagnosis of Takayasu's arteritis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1