{"title":"基于FPGA控制的多电平变换器有源谐波消除","authors":"Z. Du, L. Tolbert, J. Chiasson","doi":"10.1109/CIPE.2004.1428137","DOIUrl":null,"url":null,"abstract":"This paper presents an optimal total harmonic distortion (THD) control algorithm referred to as active harmonic elimination method for cascaded H-bridges multilevel converter control with unequal DC sources. First, the multilevel converter is decoupled into unipolar converters, the low order harmonics, such as the 5th, 7th, 11th and 13th are eliminated by using elimination theory, and the minimum THD combination of unipolar converters for multilevel converter control is found. Next, the magnitudes and phases of the residual higher harmonics are computed and subtracted from the original output voltage waveform to eliminate these higher harmonics. To validate the proposed algorithm, the method is simulated by Matlab first. After the simulation, an experimental 11-level H-bridge multilevel converter with a real-time controller based on Altera FLEX 10 K field programmable gate array (FPGA) is used to implement the algorithm with 8 /spl mu/s control resolution. The experimental results show that the method can effectively eliminate the specific harmonics as expected, and the output voltage waveforms have low THD.","PeriodicalId":137483,"journal":{"name":"2004 IEEE Workshop on Computers in Power Electronics, 2004. Proceedings.","volume":"61 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"26","resultStr":"{\"title\":\"Active harmonic elimination in multilevel converters using FPGA control\",\"authors\":\"Z. Du, L. Tolbert, J. Chiasson\",\"doi\":\"10.1109/CIPE.2004.1428137\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an optimal total harmonic distortion (THD) control algorithm referred to as active harmonic elimination method for cascaded H-bridges multilevel converter control with unequal DC sources. First, the multilevel converter is decoupled into unipolar converters, the low order harmonics, such as the 5th, 7th, 11th and 13th are eliminated by using elimination theory, and the minimum THD combination of unipolar converters for multilevel converter control is found. Next, the magnitudes and phases of the residual higher harmonics are computed and subtracted from the original output voltage waveform to eliminate these higher harmonics. To validate the proposed algorithm, the method is simulated by Matlab first. After the simulation, an experimental 11-level H-bridge multilevel converter with a real-time controller based on Altera FLEX 10 K field programmable gate array (FPGA) is used to implement the algorithm with 8 /spl mu/s control resolution. The experimental results show that the method can effectively eliminate the specific harmonics as expected, and the output voltage waveforms have low THD.\",\"PeriodicalId\":137483,\"journal\":{\"name\":\"2004 IEEE Workshop on Computers in Power Electronics, 2004. Proceedings.\",\"volume\":\"61 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-08-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"26\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2004 IEEE Workshop on Computers in Power Electronics, 2004. Proceedings.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIPE.2004.1428137\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2004 IEEE Workshop on Computers in Power Electronics, 2004. Proceedings.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIPE.2004.1428137","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Active harmonic elimination in multilevel converters using FPGA control
This paper presents an optimal total harmonic distortion (THD) control algorithm referred to as active harmonic elimination method for cascaded H-bridges multilevel converter control with unequal DC sources. First, the multilevel converter is decoupled into unipolar converters, the low order harmonics, such as the 5th, 7th, 11th and 13th are eliminated by using elimination theory, and the minimum THD combination of unipolar converters for multilevel converter control is found. Next, the magnitudes and phases of the residual higher harmonics are computed and subtracted from the original output voltage waveform to eliminate these higher harmonics. To validate the proposed algorithm, the method is simulated by Matlab first. After the simulation, an experimental 11-level H-bridge multilevel converter with a real-time controller based on Altera FLEX 10 K field programmable gate array (FPGA) is used to implement the algorithm with 8 /spl mu/s control resolution. The experimental results show that the method can effectively eliminate the specific harmonics as expected, and the output voltage waveforms have low THD.