动脉压自动控制器

G. Cavelier, A. Gauthier, K. Meier, J. Bohorquez, P. Ibarra
{"title":"动脉压自动控制器","authors":"G. Cavelier, A. Gauthier, K. Meier, J. Bohorquez, P. Ibarra","doi":"10.1109/IEMBS.1988.94633","DOIUrl":null,"url":null,"abstract":"During hypertensive crisis, intensive-care-unit physicians use vasoactive drug infusion in order to diminish the patient's elevated arterial pressure. A controller was designed to automate drug infusion during hypertensive crisis, permitting the lowering and maintenance of arterial pressure at predetermined values. It allows preprogramming of functions and alarms as well as possible supervision by the doctor. Experiments performed with anesthetized dogs were analyzed to obtain identification and validation of a physiological model. The design, simulation, and testing of an original control algorithm resulted in automatic initial identification of dog parameters, automatic setting of appropriate control parameters, and adequate lowering and posterior maintenance of desired arterial pressure level. A compact, self contained, microprocessor-based controller prototype was constructed and is currently under test.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Automatic controller of arterial pressure\",\"authors\":\"G. Cavelier, A. Gauthier, K. Meier, J. Bohorquez, P. Ibarra\",\"doi\":\"10.1109/IEMBS.1988.94633\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"During hypertensive crisis, intensive-care-unit physicians use vasoactive drug infusion in order to diminish the patient's elevated arterial pressure. A controller was designed to automate drug infusion during hypertensive crisis, permitting the lowering and maintenance of arterial pressure at predetermined values. It allows preprogramming of functions and alarms as well as possible supervision by the doctor. Experiments performed with anesthetized dogs were analyzed to obtain identification and validation of a physiological model. The design, simulation, and testing of an original control algorithm resulted in automatic initial identification of dog parameters, automatic setting of appropriate control parameters, and adequate lowering and posterior maintenance of desired arterial pressure level. A compact, self contained, microprocessor-based controller prototype was constructed and is currently under test.<<ETX>>\",\"PeriodicalId\":227170,\"journal\":{\"name\":\"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.1988.94633\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1988.94633","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在高血压危象期间,重症监护病房的医生使用血管活性药物输注来降低患者升高的动脉压。设计了一种控制器,用于在高血压危重期自动输注药物,使动脉压降低并维持在预定值。它允许功能和警报的预编程,以及可能的医生监督。对麻醉犬进行的实验进行分析,以获得生理模型的识别和验证。原始控制算法的设计、仿真和测试实现了狗参数的自动初始识别,自动设置适当的控制参数,并充分降低和维持所需的动脉压力水平。一个紧凑的,独立的,基于微处理器的控制器原型已经构建,目前正在测试中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Automatic controller of arterial pressure
During hypertensive crisis, intensive-care-unit physicians use vasoactive drug infusion in order to diminish the patient's elevated arterial pressure. A controller was designed to automate drug infusion during hypertensive crisis, permitting the lowering and maintenance of arterial pressure at predetermined values. It allows preprogramming of functions and alarms as well as possible supervision by the doctor. Experiments performed with anesthetized dogs were analyzed to obtain identification and validation of a physiological model. The design, simulation, and testing of an original control algorithm resulted in automatic initial identification of dog parameters, automatic setting of appropriate control parameters, and adequate lowering and posterior maintenance of desired arterial pressure level. A compact, self contained, microprocessor-based controller prototype was constructed and is currently under test.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Prognostic value of morphometry in papillary thyroid carcinoma An expert system approach to cystic fibrosis patient management Design and development of an electromagnetic cervical range of motion system EMG pattern classification of normal and anterior cruciate ligament injured subjects On-line system for automated auditory evoked response threshold determination
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1