交流滤波用金属化薄膜电容器的加速退化试验及失效现象

Bo Yao, Yichi Zhang, Pedro Correia, R. Wu, Sungyoung Song, I. Trintis, Haoran Wang, Huai Wang
{"title":"交流滤波用金属化薄膜电容器的加速退化试验及失效现象","authors":"Bo Yao, Yichi Zhang, Pedro Correia, R. Wu, Sungyoung Song, I. Trintis, Haoran Wang, Huai Wang","doi":"10.1109/APEC43580.2023.10131420","DOIUrl":null,"url":null,"abstract":"This paper presents the degradation testing and failure mechanisms analysis of metalized film capacitors used for AC filtering in MW power converters. Based on more than 2,800 hours of accelerated testing under accelerated AC voltage, temperature, and AC current, various electro-thermal parameter data are recorded. The results reveal that capacitance values have negligible reduction until the testing samples catastrophically fail. The capacitor hot spot temperature and case temperature are measured along the testing, which are increasing. The observations provide a new perspective on the possible failure mechanisms and condition monitoring of film capacitors in AC filtering applications.","PeriodicalId":151216,"journal":{"name":"2023 IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accelerated degradation testing and failure phenomenon of metalized film capacitors for AC filtering\",\"authors\":\"Bo Yao, Yichi Zhang, Pedro Correia, R. Wu, Sungyoung Song, I. Trintis, Haoran Wang, Huai Wang\",\"doi\":\"10.1109/APEC43580.2023.10131420\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the degradation testing and failure mechanisms analysis of metalized film capacitors used for AC filtering in MW power converters. Based on more than 2,800 hours of accelerated testing under accelerated AC voltage, temperature, and AC current, various electro-thermal parameter data are recorded. The results reveal that capacitance values have negligible reduction until the testing samples catastrophically fail. The capacitor hot spot temperature and case temperature are measured along the testing, which are increasing. The observations provide a new perspective on the possible failure mechanisms and condition monitoring of film capacitors in AC filtering applications.\",\"PeriodicalId\":151216,\"journal\":{\"name\":\"2023 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC43580.2023.10131420\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC43580.2023.10131420","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了兆瓦级变流器交流滤波用金属化薄膜电容器的退化试验及失效机理分析。在加速交流电压、温度和交流电流下进行了2800多小时的加速试验,记录了各种电热参数数据。结果表明,电容值的减小可以忽略不计,直到测试样品灾难性地失效。在测试过程中,测量了电容器的热点温度和外壳温度,两者均呈上升趋势。这些观察结果为交流滤波应用中膜电容器的可能失效机制和状态监测提供了新的视角。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Accelerated degradation testing and failure phenomenon of metalized film capacitors for AC filtering
This paper presents the degradation testing and failure mechanisms analysis of metalized film capacitors used for AC filtering in MW power converters. Based on more than 2,800 hours of accelerated testing under accelerated AC voltage, temperature, and AC current, various electro-thermal parameter data are recorded. The results reveal that capacitance values have negligible reduction until the testing samples catastrophically fail. The capacitor hot spot temperature and case temperature are measured along the testing, which are increasing. The observations provide a new perspective on the possible failure mechanisms and condition monitoring of film capacitors in AC filtering applications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Advanced Front-end Monitoring Scheme for Inductive Power Transfer Systems Based on Random Forest Regression An MPC based Power Management Method for Renewable Energy Hydrogen based DC Microgrids Overview of Machine Learning-Enabled Battery State Estimation Methods Ultra-Wideband Unidirectional Reset-Less Rogowski Coil Switch Current Sensor Topology for High-Frequency DC-DC Power Converters Common Source Inductance Compensation Technique for Dynamic Current Balancing in SiC MOSFETs Parallel Operations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1