不同类型WTG集成对径向配电系统的统计影响分析

Ankush Tandon, Pooja Jain, Abhinav Goyal, Aditya Sharma, Anoop Gupta, Anmay Kapoor
{"title":"不同类型WTG集成对径向配电系统的统计影响分析","authors":"Ankush Tandon, Pooja Jain, Abhinav Goyal, Aditya Sharma, Anoop Gupta, Anmay Kapoor","doi":"10.1109/ICEEICT56924.2023.10157080","DOIUrl":null,"url":null,"abstract":"A nation's ability to obtain electrical energy determines its socio economic progress. While keeping in mind different operational and technological restrictions, planning for distribution system expansion considers the services that must be installed for the distribution networks to manage the expected load demand. When distributed generation sources (DGs) are integrated, distribution network efficiency is increased, power losses are decreased, and voltage magnitude is also enhanced. In this paper, Wind Turbine Generator (WTG) as renewable energy source of four different types are integrated under two unique control scheme in conventional radial distribution topology. A statistical analysis of WTG integration is carried out for conventional 34 bus radial distribution system using ETAP simulation package on single and multiple locations. Voltage magnitude were analyzed under critical, marginal and nominal level before and after integrating DGs in test system. In addition to this loss reduction is also noted and analyzed while incorporating different types of WTGs.","PeriodicalId":345324,"journal":{"name":"2023 Second International Conference on Electrical, Electronics, Information and Communication Technologies (ICEEICT)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Statistical Impact Analysis of Integration of different types of WTG on Radial Distribution System\",\"authors\":\"Ankush Tandon, Pooja Jain, Abhinav Goyal, Aditya Sharma, Anoop Gupta, Anmay Kapoor\",\"doi\":\"10.1109/ICEEICT56924.2023.10157080\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A nation's ability to obtain electrical energy determines its socio economic progress. While keeping in mind different operational and technological restrictions, planning for distribution system expansion considers the services that must be installed for the distribution networks to manage the expected load demand. When distributed generation sources (DGs) are integrated, distribution network efficiency is increased, power losses are decreased, and voltage magnitude is also enhanced. In this paper, Wind Turbine Generator (WTG) as renewable energy source of four different types are integrated under two unique control scheme in conventional radial distribution topology. A statistical analysis of WTG integration is carried out for conventional 34 bus radial distribution system using ETAP simulation package on single and multiple locations. Voltage magnitude were analyzed under critical, marginal and nominal level before and after integrating DGs in test system. In addition to this loss reduction is also noted and analyzed while incorporating different types of WTGs.\",\"PeriodicalId\":345324,\"journal\":{\"name\":\"2023 Second International Conference on Electrical, Electronics, Information and Communication Technologies (ICEEICT)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 Second International Conference on Electrical, Electronics, Information and Communication Technologies (ICEEICT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEEICT56924.2023.10157080\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 Second International Conference on Electrical, Electronics, Information and Communication Technologies (ICEEICT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEEICT56924.2023.10157080","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

一个国家获得电能的能力决定了其社会经济的发展。在考虑不同的操作和技术限制的同时,规划配电系统扩展要考虑必须为配电网络安装的服务,以管理预期的负载需求。分布式电源集成后,配电网效率提高,功率损耗降低,电压幅值增大。本文将风力发电机组作为四种不同类型的可再生能源,在传统的径向分布拓扑中,采用两种独特的控制方案进行集成。利用ETAP仿真包对传统34总线径向配电系统的单点和多点WTG集成进行了统计分析。分析了测试系统集成dg前后在临界、边际和标称水平下的电压幅值。此外,在采用不同类型的wtg时,还注意并分析了这种损失减少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Statistical Impact Analysis of Integration of different types of WTG on Radial Distribution System
A nation's ability to obtain electrical energy determines its socio economic progress. While keeping in mind different operational and technological restrictions, planning for distribution system expansion considers the services that must be installed for the distribution networks to manage the expected load demand. When distributed generation sources (DGs) are integrated, distribution network efficiency is increased, power losses are decreased, and voltage magnitude is also enhanced. In this paper, Wind Turbine Generator (WTG) as renewable energy source of four different types are integrated under two unique control scheme in conventional radial distribution topology. A statistical analysis of WTG integration is carried out for conventional 34 bus radial distribution system using ETAP simulation package on single and multiple locations. Voltage magnitude were analyzed under critical, marginal and nominal level before and after integrating DGs in test system. In addition to this loss reduction is also noted and analyzed while incorporating different types of WTGs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Transient Stability Analysis of Wind Farm Integrated Power Systems using PSAT Energy Efficient Dual Mode DCVSL (DM-DCVSL) design Evaluation of ML Models for Detection and Prediction of Fish Diseases: A Case Study on Epizootic Ulcerative Syndrome Multiple Renewable Sources Integrated Micro Grid with ANFIS Based Charge and Discharge Control of Battery for Optimal Power Sharing 3D Based CT Scan Retrial Queuing Models by Fuzzy Ordering Approach
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1