{"title":"基于SDS的公寓框架桩基动力离心试验数量经济分析对比研究","authors":"Sang-Yeon Kim, Jongbae Park, Yong-Boo Park","doi":"10.5804/LHIJ.2015.6.3.147","DOIUrl":null,"url":null,"abstract":"ABSTRACT Site coefficient and amplification factor of current domestic Seismic Design Code based on American Seismic Code, have no consideration for the domestic ground condition in which the base rock is normally placed within 30m form the surface. By previous studies, the measured spectral acceleration of the result of dynamic centrifugal test and analysis was smaller than the design spectral acceleration for the period over 1.5 sec. Accordingly, in this study structural analysis and design using dynamic centrifugal test result for pile foundation were achieved, and the quantity of concrete and reinforcement of wall frame was compared with each other. Comparison results of cost using KBC the design spectral acceleration of SC, SD site and SDS, the quantity of reinforcement using SDS for SD site was 17~23% smaller than using the design code SD site. Key words : Pile Foundation, Dynamic Test, Site Coefficient, Design Spectral Acceleration, Cost Compare 1) 한국토지주택공사 토지주택연구원 수석연구원(주저자: sy-kim@lh.or.kr)2) 한국토지주택공사 토지주택연구원 수석연구원(교신저자: jbpark@lh.or.kr)3) 한국토지주택공사 토지주택연구원 수석연구원","PeriodicalId":365439,"journal":{"name":"LHI journal of land, housing, and urban affairs","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative Study on the Quantity Economic Analysis of Apartment Frames Using SDS Result of Dynamic Centrifuge Test at Pile Foundation\",\"authors\":\"Sang-Yeon Kim, Jongbae Park, Yong-Boo Park\",\"doi\":\"10.5804/LHIJ.2015.6.3.147\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT Site coefficient and amplification factor of current domestic Seismic Design Code based on American Seismic Code, have no consideration for the domestic ground condition in which the base rock is normally placed within 30m form the surface. By previous studies, the measured spectral acceleration of the result of dynamic centrifugal test and analysis was smaller than the design spectral acceleration for the period over 1.5 sec. Accordingly, in this study structural analysis and design using dynamic centrifugal test result for pile foundation were achieved, and the quantity of concrete and reinforcement of wall frame was compared with each other. Comparison results of cost using KBC the design spectral acceleration of SC, SD site and SDS, the quantity of reinforcement using SDS for SD site was 17~23% smaller than using the design code SD site. Key words : Pile Foundation, Dynamic Test, Site Coefficient, Design Spectral Acceleration, Cost Compare 1) 한국토지주택공사 토지주택연구원 수석연구원(주저자: sy-kim@lh.or.kr)2) 한국토지주택공사 토지주택연구원 수석연구원(교신저자: jbpark@lh.or.kr)3) 한국토지주택공사 토지주택연구원 수석연구원\",\"PeriodicalId\":365439,\"journal\":{\"name\":\"LHI journal of land, housing, and urban affairs\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"LHI journal of land, housing, and urban affairs\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5804/LHIJ.2015.6.3.147\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"LHI journal of land, housing, and urban affairs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5804/LHIJ.2015.6.3.147","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparative Study on the Quantity Economic Analysis of Apartment Frames Using SDS Result of Dynamic Centrifuge Test at Pile Foundation
ABSTRACT Site coefficient and amplification factor of current domestic Seismic Design Code based on American Seismic Code, have no consideration for the domestic ground condition in which the base rock is normally placed within 30m form the surface. By previous studies, the measured spectral acceleration of the result of dynamic centrifugal test and analysis was smaller than the design spectral acceleration for the period over 1.5 sec. Accordingly, in this study structural analysis and design using dynamic centrifugal test result for pile foundation were achieved, and the quantity of concrete and reinforcement of wall frame was compared with each other. Comparison results of cost using KBC the design spectral acceleration of SC, SD site and SDS, the quantity of reinforcement using SDS for SD site was 17~23% smaller than using the design code SD site. Key words : Pile Foundation, Dynamic Test, Site Coefficient, Design Spectral Acceleration, Cost Compare 1) 한국토지주택공사 토지주택연구원 수석연구원(주저자: sy-kim@lh.or.kr)2) 한국토지주택공사 토지주택연구원 수석연구원(교신저자: jbpark@lh.or.kr)3) 한국토지주택공사 토지주택연구원 수석연구원