{"title":"配电系统中的系列控制器-便于增加负载","authors":"R. D. de Graaff, J. Myrzik, W. Kling, J. Enslin","doi":"10.1109/UPEC.2006.367736","DOIUrl":null,"url":null,"abstract":"Medium voltage distribution feeders are generally not loaded to their nominal rating because of redundancy considerations. During repair of a faulted feeder the loads will be switched to another feeder to limit the customer interruption time. This spare capacity needs to be reserved on each of the concerned cables. To make some of the spare capacity available for increased loading the application of a series controller is proposed. This paper shows simulations of cable distribution systems both with and without series controllers, and compares the results. It is shown how series controllers can increase the maximum loading of distribution systems.","PeriodicalId":184186,"journal":{"name":"Proceedings of the 41st International Universities Power Engineering Conference","volume":"2013 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Series Controllers in Distribution Systems - Facilitating Increased Loading\",\"authors\":\"R. D. de Graaff, J. Myrzik, W. Kling, J. Enslin\",\"doi\":\"10.1109/UPEC.2006.367736\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Medium voltage distribution feeders are generally not loaded to their nominal rating because of redundancy considerations. During repair of a faulted feeder the loads will be switched to another feeder to limit the customer interruption time. This spare capacity needs to be reserved on each of the concerned cables. To make some of the spare capacity available for increased loading the application of a series controller is proposed. This paper shows simulations of cable distribution systems both with and without series controllers, and compares the results. It is shown how series controllers can increase the maximum loading of distribution systems.\",\"PeriodicalId\":184186,\"journal\":{\"name\":\"Proceedings of the 41st International Universities Power Engineering Conference\",\"volume\":\"2013 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 41st International Universities Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2006.367736\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 41st International Universities Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2006.367736","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Series Controllers in Distribution Systems - Facilitating Increased Loading
Medium voltage distribution feeders are generally not loaded to their nominal rating because of redundancy considerations. During repair of a faulted feeder the loads will be switched to another feeder to limit the customer interruption time. This spare capacity needs to be reserved on each of the concerned cables. To make some of the spare capacity available for increased loading the application of a series controller is proposed. This paper shows simulations of cable distribution systems both with and without series controllers, and compares the results. It is shown how series controllers can increase the maximum loading of distribution systems.