从替代加热系统和人体工程学角度对Grashof培养箱进行重新设计

B. Arthaya, C. Tesavrita, Priyatna Permana
{"title":"从替代加热系统和人体工程学角度对Grashof培养箱进行重新设计","authors":"B. Arthaya, C. Tesavrita, Priyatna Permana","doi":"10.1109/AIMS.2015.86","DOIUrl":null,"url":null,"abstract":"Delivering neonatal babies is still happening in Indonesia and low incomes families often cannot afford to buy/rent baby incubators during the baby critical growing period. Charity groups are lending electrically driven Grashof incubators freely to whom that have financial difficulties. Free incubator still does not immediately solve the problem of the families as nowadays supply of electricity from our Indonesian State Electricity Company to some areas is not delivered constantly. As a result, electricity blackout appears frequently especially at under developed regions even in Jakarta regions.This issue makes such a tremendous anxiety for those families as the incubators heating system cannot work properly.Redesigning of heating system of the incubator will be the solution to the problem. The redesign is to find alternative energy sources that maintain cabin temperature when electricity is out. The new alternative energy a heat exchanger based on hot water flowing in a tubular heating system. The usability of the device is to be considered due to the current device cannot be suitably operated by common people, where some difficulties still appear when operating of the unit. The incubator must also be confidently safe for the neonatal babies and their parents.","PeriodicalId":121874,"journal":{"name":"2015 3rd International Conference on Artificial Intelligence, Modelling and Simulation (AIMS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The Redesign of Grashof Incubator Concerning the Alternative Heating System and the Ergonomic Aspect\",\"authors\":\"B. Arthaya, C. Tesavrita, Priyatna Permana\",\"doi\":\"10.1109/AIMS.2015.86\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Delivering neonatal babies is still happening in Indonesia and low incomes families often cannot afford to buy/rent baby incubators during the baby critical growing period. Charity groups are lending electrically driven Grashof incubators freely to whom that have financial difficulties. Free incubator still does not immediately solve the problem of the families as nowadays supply of electricity from our Indonesian State Electricity Company to some areas is not delivered constantly. As a result, electricity blackout appears frequently especially at under developed regions even in Jakarta regions.This issue makes such a tremendous anxiety for those families as the incubators heating system cannot work properly.Redesigning of heating system of the incubator will be the solution to the problem. The redesign is to find alternative energy sources that maintain cabin temperature when electricity is out. The new alternative energy a heat exchanger based on hot water flowing in a tubular heating system. The usability of the device is to be considered due to the current device cannot be suitably operated by common people, where some difficulties still appear when operating of the unit. The incubator must also be confidently safe for the neonatal babies and their parents.\",\"PeriodicalId\":121874,\"journal\":{\"name\":\"2015 3rd International Conference on Artificial Intelligence, Modelling and Simulation (AIMS)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 3rd International Conference on Artificial Intelligence, Modelling and Simulation (AIMS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AIMS.2015.86\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 3rd International Conference on Artificial Intelligence, Modelling and Simulation (AIMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AIMS.2015.86","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在印度尼西亚,新生儿的分娩仍在发生,低收入家庭在婴儿关键生长时期往往买不起/租不起婴儿保育箱。慈善团体免费将电动Grashof孵化器借给有经济困难的人。免费的孵化器仍然不能立即解决家庭的问题,因为目前印度尼西亚国家电力公司向一些地区的电力供应并不是持续的。因此,经常发生停电,特别是在欠发达地区,甚至在雅加达地区。这个问题让这些家庭非常焦虑,因为恒温箱的加热系统不能正常工作。对培养箱加热系统进行重新设计是解决这一问题的有效途径。重新设计是为了寻找替代能源,在停电时保持机舱温度。一种新的替代能源是基于热水在管式供热系统中流动的换热器。设备的可用性是需要考虑的,因为目前的设备不能被普通的人适当的操作,在操作装置的时候仍然会出现一些困难。保温箱还必须保证新生儿及其父母的安全。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Redesign of Grashof Incubator Concerning the Alternative Heating System and the Ergonomic Aspect
Delivering neonatal babies is still happening in Indonesia and low incomes families often cannot afford to buy/rent baby incubators during the baby critical growing period. Charity groups are lending electrically driven Grashof incubators freely to whom that have financial difficulties. Free incubator still does not immediately solve the problem of the families as nowadays supply of electricity from our Indonesian State Electricity Company to some areas is not delivered constantly. As a result, electricity blackout appears frequently especially at under developed regions even in Jakarta regions.This issue makes such a tremendous anxiety for those families as the incubators heating system cannot work properly.Redesigning of heating system of the incubator will be the solution to the problem. The redesign is to find alternative energy sources that maintain cabin temperature when electricity is out. The new alternative energy a heat exchanger based on hot water flowing in a tubular heating system. The usability of the device is to be considered due to the current device cannot be suitably operated by common people, where some difficulties still appear when operating of the unit. The incubator must also be confidently safe for the neonatal babies and their parents.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Real Time Detection and Tracking of Mouth Region of Single Human Face Tamper Detection in Speech Based Access Control Systems Using Watermarking A Clustering Algorithm for WSN to Optimize the Network Lifetime Using Type-2 Fuzzy Logic Model On the Trade-Off between Multi-level Security Classification Accuracy and Training Time An Improved Quality of Service Using R-AODV Protocol in MANETs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1