{"title":"Leksell立体定向框架的两项技术改进","authors":"Faiz A. Jumaa, Samir Z. Al-kaabi, B. Kadhum, Moneer K. Faraj","doi":"10.5580/1eab","DOIUrl":null,"url":null,"abstract":"Objective: We describe newly designed frame holder applied to the head before pin fixation. The already available ear plugs facilitate the straight alignment of the frame by fixing it to the external auditory meatus, but they are quite painful for most of the patients and not prevent the anterior posterior rotation. (2,3) The Leksell frame (Elekta, Sweden) is provided with a clamp that fits only with Mayfield head frame(SM, USA).(1) We performed certain modifications to make the frame fit to the Sugita head clamp (Mizuho, Japan); the only sort of head frame we have in our hospital. Patients & methods: The new modifications were used to fifteen patients in whom the application of the frame was indicated. A new designed net made of sewed ribbons applied to the head before pin fixation. It prevents slipping of the frame especially with the aid of the top plastic cup for its suction ability over a well shaved head. No pain recorded with its use. The other modification was to make few changes with the sugita head clamp middle piece to make it adaptable with that of the leksell which was originally designed for the Mayfield head clamp. Results: The newly designed net caused no pain to all the patients .Slipping was minimal. The time of the application of the frame shortened. With the use of the new adapter with the leksell frame, we were able to perform surgical interventions even as long as 8 hours as in deep brain stimulation operations with no movement noticed between the frame and the operating table. Conclusion: These two technical modifications were useful to help in application of the frame over the patients head with minimal slipping movement and no pain. It permitted us to use the leksell frame with the sugita head frame which is the only sort of head frame we have in our hospital. NOTICE This paper has been designed to resolve certain problems we faced in our work in the neurosciences hospital. We did not receive any financial support from any company mentioned in this paper. INTRODUCTION The Leksell Frame (Elekta, Sweden) is widely used for functional neurosurgical operations. For the proper application of the frame on the patients head; it is provided with ear plugs .these will prevent side way movement but it is quite painful & cannot be tolerated actually with all our patients. Also it will not prevent the foreword backward slipping of the frame. (2, 3) The frame is provided with head clamp compatible with only the Mayfield head holder (SM, USA) (1); making it unadoptable with the head frames like the sugita head frame (Mizuho, Japan); the only sort of head frame we have in our hospital. PATIENTS& METHODS In late 2007 & early 2008 we used these techniques for fifteen patients. Nine had deep brain stimulation (DBS) of the subthalamic nucleus for Parkinson's disease; one patient had DBS of the ventral intermediate nucleus for rubral tremor. One patient had DBS of the Globous pallidus internus nucleus for Dystonia. One patient had stereotactic removal of tuberculomas using the Steiner Lindquist laser guide (Elekta, Sweden); the last three patients it was used for stereotactic biopsy of deeply seated brain tumors. The Leksell frame fixation is usually done in the radiology department. The head frame holder is composed of three Two Technical Modifications for the Leksell Stereotactic Frame 2 of 4 straps sewed together to hold the temporal & occipital bars of the frame. The top of each strap is connected with plastic cup to fit firmly to the head & prevents its slipping by its suction ability over a well shaved head. Each one of them is sewed in its end with a tag to allow readjustment of the frame on the head. The straps on the temporal bars composed of two pairs to let an opening to observe the external auditory meatus; this is needed to align the frame along the canthomeatal line. We apply it of the patients head & fit the frame within its multi adhesive tags. The alignment of the frame can be readjusted frequently until we fix the pins & remove the straps. These straps didn't cause any pain or discomfort as the ear plug did to all the patients. They also prevent unwanted wide movement or slipping of the frame. Figures (1, 2, 3) Figure 1 Figure 1: The five straps sewed together, they are connected in their ends with tags to adjust its length. Figure 2 Figure 2: The straps applied to the leksell frame on both temporal bars ( two ribbons on each side) & the occipital one.","PeriodicalId":326784,"journal":{"name":"The Internet Journal of Neurosurgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Two Technical Modifications for the Leksell Stereotactic Frame\",\"authors\":\"Faiz A. Jumaa, Samir Z. Al-kaabi, B. Kadhum, Moneer K. Faraj\",\"doi\":\"10.5580/1eab\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: We describe newly designed frame holder applied to the head before pin fixation. The already available ear plugs facilitate the straight alignment of the frame by fixing it to the external auditory meatus, but they are quite painful for most of the patients and not prevent the anterior posterior rotation. (2,3) The Leksell frame (Elekta, Sweden) is provided with a clamp that fits only with Mayfield head frame(SM, USA).(1) We performed certain modifications to make the frame fit to the Sugita head clamp (Mizuho, Japan); the only sort of head frame we have in our hospital. Patients & methods: The new modifications were used to fifteen patients in whom the application of the frame was indicated. A new designed net made of sewed ribbons applied to the head before pin fixation. It prevents slipping of the frame especially with the aid of the top plastic cup for its suction ability over a well shaved head. No pain recorded with its use. The other modification was to make few changes with the sugita head clamp middle piece to make it adaptable with that of the leksell which was originally designed for the Mayfield head clamp. Results: The newly designed net caused no pain to all the patients .Slipping was minimal. The time of the application of the frame shortened. With the use of the new adapter with the leksell frame, we were able to perform surgical interventions even as long as 8 hours as in deep brain stimulation operations with no movement noticed between the frame and the operating table. Conclusion: These two technical modifications were useful to help in application of the frame over the patients head with minimal slipping movement and no pain. It permitted us to use the leksell frame with the sugita head frame which is the only sort of head frame we have in our hospital. NOTICE This paper has been designed to resolve certain problems we faced in our work in the neurosciences hospital. We did not receive any financial support from any company mentioned in this paper. INTRODUCTION The Leksell Frame (Elekta, Sweden) is widely used for functional neurosurgical operations. For the proper application of the frame on the patients head; it is provided with ear plugs .these will prevent side way movement but it is quite painful & cannot be tolerated actually with all our patients. Also it will not prevent the foreword backward slipping of the frame. (2, 3) The frame is provided with head clamp compatible with only the Mayfield head holder (SM, USA) (1); making it unadoptable with the head frames like the sugita head frame (Mizuho, Japan); the only sort of head frame we have in our hospital. PATIENTS& METHODS In late 2007 & early 2008 we used these techniques for fifteen patients. Nine had deep brain stimulation (DBS) of the subthalamic nucleus for Parkinson's disease; one patient had DBS of the ventral intermediate nucleus for rubral tremor. One patient had DBS of the Globous pallidus internus nucleus for Dystonia. One patient had stereotactic removal of tuberculomas using the Steiner Lindquist laser guide (Elekta, Sweden); the last three patients it was used for stereotactic biopsy of deeply seated brain tumors. The Leksell frame fixation is usually done in the radiology department. The head frame holder is composed of three Two Technical Modifications for the Leksell Stereotactic Frame 2 of 4 straps sewed together to hold the temporal & occipital bars of the frame. The top of each strap is connected with plastic cup to fit firmly to the head & prevents its slipping by its suction ability over a well shaved head. Each one of them is sewed in its end with a tag to allow readjustment of the frame on the head. The straps on the temporal bars composed of two pairs to let an opening to observe the external auditory meatus; this is needed to align the frame along the canthomeatal line. We apply it of the patients head & fit the frame within its multi adhesive tags. The alignment of the frame can be readjusted frequently until we fix the pins & remove the straps. These straps didn't cause any pain or discomfort as the ear plug did to all the patients. They also prevent unwanted wide movement or slipping of the frame. Figures (1, 2, 3) Figure 1 Figure 1: The five straps sewed together, they are connected in their ends with tags to adjust its length. Figure 2 Figure 2: The straps applied to the leksell frame on both temporal bars ( two ribbons on each side) & the occipital one.\",\"PeriodicalId\":326784,\"journal\":{\"name\":\"The Internet Journal of Neurosurgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Internet Journal of Neurosurgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5580/1eab\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Internet Journal of Neurosurgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5580/1eab","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:介绍一种新设计的框架支架,应用于头部钉固定前。现有的耳塞通过将框架固定在外耳道上,促进框架的直线排列,但对大多数患者来说,耳塞非常痛苦,而且不能防止前后旋转。(2,3) Leksell框架(Elekta,瑞典)提供了一个夹具,只适合Mayfield头框架(SM,美国)。(1)我们进行了一定的修改,使框架适合Sugita头夹具(Mizuho,日本);这是我们医院唯一的一种头框。患者和方法:新修改的框架应用于15例患者。一种新设计的网,由缝带制成,在针固定之前应用于头部。它可以防止框架滑动,特别是在顶部塑料杯的帮助下,它的吸力超过一个剃光的头。使用后无疼痛记录。另一个修改是使杉田头夹中间件很少的变化,使其适应的leksell最初是为梅菲尔德头夹设计的。结果:新设计的网无疼痛感,滑倒最小。缩短了框架的应用时间。使用leksell框架的新适配器,我们能够进行长达8小时的手术干预,就像在深部脑刺激手术中一样,框架和手术台之间没有任何运动。结论:这两种技术改进有助于将框架套在患者头上,滑动运动最小,无疼痛。它允许我们使用leksell框架和杉田头框架,这是我们医院唯一一种头框架。这篇论文是为了解决我们在神经科学医院工作中遇到的一些问题而设计的。我们没有得到本文中提到的任何公司的任何资金支持。Leksell框架(Elekta, Sweden)广泛用于功能性神经外科手术。为患者头部支架的正确应用;它配有耳塞,这可以防止侧身运动,但这是非常痛苦的,实际上我们所有的病人都不能容忍。它也不能防止前言向后滑动的框架。(2,3)机架配有头夹,仅与Mayfield头夹(SM, USA)(1)兼容;使其无法与杉田头架(Mizuho,日本)等头架配套使用;这是我们医院唯一的一种头框。患者和方法在2007年末和2008年初,我们对15名患者使用了这些技术。9例帕金森病患者采用丘脑下核深部脑刺激(DBS)治疗;1例震颤患者腹侧中间核DBS。1例患者因肌张力障碍行白球内核DBS。1例患者使用Steiner Lindquist激光导引(Elekta,瑞典)进行了立体定向切除结核瘤;最后三个病人被用于深部脑肿瘤的立体定向活检。Leksell框架固定通常在放射科进行。头框架支架由3个Leksell立体定向框架2的2个技术修改组成,其中4条绑带缝在一起,用于固定框架的颞部和枕部。每个表带的顶部与塑料杯连接,以牢固地配合头部,并防止其滑落,其吸力超过剃光的头部。每一个都在其末端缝有一个标签,以便重新调整头部的框架。颞骨条上的绑带由两对组成,以开孔观察外耳道;这是需要沿着角鼻线对齐框架。我们将其应用于患者头部,并将框架安装在其多粘胶标签内。框架的对准可以经常调整,直到我们固定销和拆除带子。这些带子不会像耳塞那样给病人带来任何疼痛或不适。他们还防止不必要的广泛运动或滑动的框架。图(1、2、3)图1图1:五根绑带缝在一起,两端用吊牌连接,调节长度。图2:系于leksell框架两侧颞骨条(两侧各两条)和枕骨条的绑带。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Two Technical Modifications for the Leksell Stereotactic Frame
Objective: We describe newly designed frame holder applied to the head before pin fixation. The already available ear plugs facilitate the straight alignment of the frame by fixing it to the external auditory meatus, but they are quite painful for most of the patients and not prevent the anterior posterior rotation. (2,3) The Leksell frame (Elekta, Sweden) is provided with a clamp that fits only with Mayfield head frame(SM, USA).(1) We performed certain modifications to make the frame fit to the Sugita head clamp (Mizuho, Japan); the only sort of head frame we have in our hospital. Patients & methods: The new modifications were used to fifteen patients in whom the application of the frame was indicated. A new designed net made of sewed ribbons applied to the head before pin fixation. It prevents slipping of the frame especially with the aid of the top plastic cup for its suction ability over a well shaved head. No pain recorded with its use. The other modification was to make few changes with the sugita head clamp middle piece to make it adaptable with that of the leksell which was originally designed for the Mayfield head clamp. Results: The newly designed net caused no pain to all the patients .Slipping was minimal. The time of the application of the frame shortened. With the use of the new adapter with the leksell frame, we were able to perform surgical interventions even as long as 8 hours as in deep brain stimulation operations with no movement noticed between the frame and the operating table. Conclusion: These two technical modifications were useful to help in application of the frame over the patients head with minimal slipping movement and no pain. It permitted us to use the leksell frame with the sugita head frame which is the only sort of head frame we have in our hospital. NOTICE This paper has been designed to resolve certain problems we faced in our work in the neurosciences hospital. We did not receive any financial support from any company mentioned in this paper. INTRODUCTION The Leksell Frame (Elekta, Sweden) is widely used for functional neurosurgical operations. For the proper application of the frame on the patients head; it is provided with ear plugs .these will prevent side way movement but it is quite painful & cannot be tolerated actually with all our patients. Also it will not prevent the foreword backward slipping of the frame. (2, 3) The frame is provided with head clamp compatible with only the Mayfield head holder (SM, USA) (1); making it unadoptable with the head frames like the sugita head frame (Mizuho, Japan); the only sort of head frame we have in our hospital. PATIENTS& METHODS In late 2007 & early 2008 we used these techniques for fifteen patients. Nine had deep brain stimulation (DBS) of the subthalamic nucleus for Parkinson's disease; one patient had DBS of the ventral intermediate nucleus for rubral tremor. One patient had DBS of the Globous pallidus internus nucleus for Dystonia. One patient had stereotactic removal of tuberculomas using the Steiner Lindquist laser guide (Elekta, Sweden); the last three patients it was used for stereotactic biopsy of deeply seated brain tumors. The Leksell frame fixation is usually done in the radiology department. The head frame holder is composed of three Two Technical Modifications for the Leksell Stereotactic Frame 2 of 4 straps sewed together to hold the temporal & occipital bars of the frame. The top of each strap is connected with plastic cup to fit firmly to the head & prevents its slipping by its suction ability over a well shaved head. Each one of them is sewed in its end with a tag to allow readjustment of the frame on the head. The straps on the temporal bars composed of two pairs to let an opening to observe the external auditory meatus; this is needed to align the frame along the canthomeatal line. We apply it of the patients head & fit the frame within its multi adhesive tags. The alignment of the frame can be readjusted frequently until we fix the pins & remove the straps. These straps didn't cause any pain or discomfort as the ear plug did to all the patients. They also prevent unwanted wide movement or slipping of the frame. Figures (1, 2, 3) Figure 1 Figure 1: The five straps sewed together, they are connected in their ends with tags to adjust its length. Figure 2 Figure 2: The straps applied to the leksell frame on both temporal bars ( two ribbons on each side) & the occipital one.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Bigbrain Model: An Atlas, A Chimera Or A Glance Into The Future? Intracranial Meningioma Manifesting As Transient Ischemic Attack Magnetic Resonance Imaging And Computer NLS-Graphy And In Evaluation Of Surgical Intervention Extent For Brain Tumors Treatment. Deep Brain Stimulation for Treatment of Parkinson’s Disease Deep brain stimulation, Parkinson’s disease, subthalamic nucleus, stereotactic surgery Brain Death: History, Updated Guidelines And Unanswered Questions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1