{"title":"基于连续潮流应急电压稳定的STATCOM和SVC优化配置——以伊朗Khouzestan电网为例","authors":"Farbod Larki, H. M. Kelk, M. Pishvaei, A. Johar, M. Joorabian","doi":"10.1109/ICCEE.2009.84","DOIUrl":null,"url":null,"abstract":"This paper presents a new approach for identification of optimal locations of STATCOM and SVC. The power system operates in stability boundary and system probably loses its stability by occurring disturbance, so considering contingency outage and recognition of voltage instability in allocation of shunt FACTS devices has importance. This paper by considering of power system contingencies based on the effects of them on static voltage stability specifies optimal location for installation SVC and STATCOM. The method for analyze voltage stability is continuation power flow and simulated case studies conducted on Kouzestan power networks in Iran based on the proposed techniques.","PeriodicalId":343870,"journal":{"name":"2009 Second International Conference on Computer and Electrical Engineering","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Optimal Location of STATCOM and SVC Based on Contingency Voltage Stability by Using Continuation Power Flow: Case Studies of Khouzestan Power Networks in Iran\",\"authors\":\"Farbod Larki, H. M. Kelk, M. Pishvaei, A. Johar, M. Joorabian\",\"doi\":\"10.1109/ICCEE.2009.84\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a new approach for identification of optimal locations of STATCOM and SVC. The power system operates in stability boundary and system probably loses its stability by occurring disturbance, so considering contingency outage and recognition of voltage instability in allocation of shunt FACTS devices has importance. This paper by considering of power system contingencies based on the effects of them on static voltage stability specifies optimal location for installation SVC and STATCOM. The method for analyze voltage stability is continuation power flow and simulated case studies conducted on Kouzestan power networks in Iran based on the proposed techniques.\",\"PeriodicalId\":343870,\"journal\":{\"name\":\"2009 Second International Conference on Computer and Electrical Engineering\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Second International Conference on Computer and Electrical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCEE.2009.84\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Second International Conference on Computer and Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCEE.2009.84","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

本文提出了一种新的STATCOM和SVC最优位置识别方法。电力系统运行在稳定边界上,系统有可能因发生扰动而失去稳定,因此在并联FACTS设备配置中考虑突发停电和电压不稳定识别具有重要意义。考虑电力系统突发事件对静态电压稳定性的影响,确定了SVC和STATCOM的最佳安装位置。电压稳定性分析的方法是连续潮流分析,并在此基础上对伊朗Kouzestan电网进行了仿真研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimal Location of STATCOM and SVC Based on Contingency Voltage Stability by Using Continuation Power Flow: Case Studies of Khouzestan Power Networks in Iran
This paper presents a new approach for identification of optimal locations of STATCOM and SVC. The power system operates in stability boundary and system probably loses its stability by occurring disturbance, so considering contingency outage and recognition of voltage instability in allocation of shunt FACTS devices has importance. This paper by considering of power system contingencies based on the effects of them on static voltage stability specifies optimal location for installation SVC and STATCOM. The method for analyze voltage stability is continuation power flow and simulated case studies conducted on Kouzestan power networks in Iran based on the proposed techniques.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
ID Based Signature Schemes for Electronic Voting Service Oriented Approach to Improve the Power of Snorts On-line Colour Image Compression Based on Pipelined Architecture CMMP: Clustering-Based Multi-channel MAC Protocol in VANET Computer Aided Protection (Overcurrent) Coordination Studies
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1