用于ICARUS T600探测器的20个预系列滨松R5916-MOD光电倍增管的测试和表征

G. Raselli, M. Babicz, V. Bellini, M. Bonesini, T. Cervi, A. Falcone, U. Kose, A. Menegolli, C. Montanari, M. Nessi, F. Pietropaolo, M. Rossella, M. Spanu, M. Torti, F. Tortorici, A. Zani
{"title":"用于ICARUS T600探测器的20个预系列滨松R5916-MOD光电倍增管的测试和表征","authors":"G. Raselli, M. Babicz, V. Bellini, M. Bonesini, T. Cervi, A. Falcone, U. Kose, A. Menegolli, C. Montanari, M. Nessi, F. Pietropaolo, M. Rossella, M. Spanu, M. Torti, F. Tortorici, A. Zani","doi":"10.1109/NSSMIC.2016.8069768","DOIUrl":null,"url":null,"abstract":"ICARUS T600 will become the far detector of the Short Baseline Neutrino program at FNAL (USA), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line. The apparatus is now under refurbishing at CERN. A new light detection system is foreseen, using four planes of photo-multiplier tubes (PMTs) with 90 units each. A first pre-series of 20 PMTs Hamamatsu R5912-MOD, 8 in. diameter suitable for cryogenic applications, was fully tested, both at room and at liquid argon temperature, to ensure good performance of the detector.","PeriodicalId":184587,"journal":{"name":"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Test and characterization of 20 pre-series hamamatsu R5916-MOD photomultiplier tubes for the ICARUS T600 detector\",\"authors\":\"G. Raselli, M. Babicz, V. Bellini, M. Bonesini, T. Cervi, A. Falcone, U. Kose, A. Menegolli, C. Montanari, M. Nessi, F. Pietropaolo, M. Rossella, M. Spanu, M. Torti, F. Tortorici, A. Zani\",\"doi\":\"10.1109/NSSMIC.2016.8069768\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ICARUS T600 will become the far detector of the Short Baseline Neutrino program at FNAL (USA), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line. The apparatus is now under refurbishing at CERN. A new light detection system is foreseen, using four planes of photo-multiplier tubes (PMTs) with 90 units each. A first pre-series of 20 PMTs Hamamatsu R5912-MOD, 8 in. diameter suitable for cryogenic applications, was fully tested, both at room and at liquid argon temperature, to ensure good performance of the detector.\",\"PeriodicalId\":184587,\"journal\":{\"name\":\"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2016.8069768\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2016.8069768","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

ICARUS T600将成为FNAL(美国)短基线中微子项目的远端探测器,该项目预计沿助推中微子束流线有三个液态氩时间投影室。该仪器目前正在欧洲核子研究中心进行翻新。一种新的光探测系统预计将使用四个平面的光倍增管(pmt),每个平面有90个单位。第一个预系列20 pmt滨松R5912-MOD, 8英寸。直径适合深冷应用,在室温和液氩温度下都进行了充分的测试,以确保探测器的良好性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Test and characterization of 20 pre-series hamamatsu R5916-MOD photomultiplier tubes for the ICARUS T600 detector
ICARUS T600 will become the far detector of the Short Baseline Neutrino program at FNAL (USA), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line. The apparatus is now under refurbishing at CERN. A new light detection system is foreseen, using four planes of photo-multiplier tubes (PMTs) with 90 units each. A first pre-series of 20 PMTs Hamamatsu R5912-MOD, 8 in. diameter suitable for cryogenic applications, was fully tested, both at room and at liquid argon temperature, to ensure good performance of the detector.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of flexible, scalable, low cost readout for beam tests of the high granularity calorimeter for the CMS endcap Latest frontier technology and design of the ATLAS calorimeter trigger board dedicated to jet identification for the LHC run 3 The ATLAS tile calorimeter DCS for run 2 The phase-II ATLAS pixel tracker upgrade: Layout and mechanics Null-hypothesis testing using distance metrics for verification of arms-control treaties
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1