陶瓷过滤器反冲洗压力波动的研究

Shaowu Zhang, Jun Zhao, Jiang Han, Zhijun Hu
{"title":"陶瓷过滤器反冲洗压力波动的研究","authors":"Shaowu Zhang, Jun Zhao, Jiang Han, Zhijun Hu","doi":"10.1109/ICSSEM.2011.6081325","DOIUrl":null,"url":null,"abstract":"In the present study, we analyzed the origin of pressure fluctuation of ceramic filter during recoiling washing process and found that reducing such pressure fluctuation necessitates the use of an accumulator or the structure improvement of distribution valve. By employing the TT-12 type of ceramic filter machine as an example, according to known conditions and through calculation and analysis, we determined the air pressure and accumulator volume and chose the NXQA-16/10-L-A accumulator. By employing the TT-45 type of ceramic filter machine as an example, changing the internal structure of the distribution valve from round to waist, the backwash time was prolonged. With the use of the two kinds of methods, we demonstrated that the pressure fluctuation was reduced to be within 0.02 MPa, which satisfied the requirements for recoiling washing.","PeriodicalId":406311,"journal":{"name":"2011 International Conference on System science, Engineering design and Manufacturing informatization","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Research on the pressure fluctuation of ceramic filter backwash\",\"authors\":\"Shaowu Zhang, Jun Zhao, Jiang Han, Zhijun Hu\",\"doi\":\"10.1109/ICSSEM.2011.6081325\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the present study, we analyzed the origin of pressure fluctuation of ceramic filter during recoiling washing process and found that reducing such pressure fluctuation necessitates the use of an accumulator or the structure improvement of distribution valve. By employing the TT-12 type of ceramic filter machine as an example, according to known conditions and through calculation and analysis, we determined the air pressure and accumulator volume and chose the NXQA-16/10-L-A accumulator. By employing the TT-45 type of ceramic filter machine as an example, changing the internal structure of the distribution valve from round to waist, the backwash time was prolonged. With the use of the two kinds of methods, we demonstrated that the pressure fluctuation was reduced to be within 0.02 MPa, which satisfied the requirements for recoiling washing.\",\"PeriodicalId\":406311,\"journal\":{\"name\":\"2011 International Conference on System science, Engineering design and Manufacturing informatization\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on System science, Engineering design and Manufacturing informatization\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSSEM.2011.6081325\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on System science, Engineering design and Manufacturing informatization","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSSEM.2011.6081325","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文分析了陶瓷过滤器在反冲洗涤过程中压力波动的原因,发现减小压力波动需要使用蓄能器或改进配流阀的结构。以TT-12型陶瓷过滤机为例,根据已知条件,通过计算分析,确定了空气压力和蓄能器体积,选择了NXQA-16/10-L-A蓄能器。以TT-45型陶瓷过滤机为例,将分配阀的内部结构由圆形改为腰部,延长了反冲洗时间。结果表明,两种方法均可将压力波动减小到0.02 MPa以内,满足反冲洗涤的要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Research on the pressure fluctuation of ceramic filter backwash
In the present study, we analyzed the origin of pressure fluctuation of ceramic filter during recoiling washing process and found that reducing such pressure fluctuation necessitates the use of an accumulator or the structure improvement of distribution valve. By employing the TT-12 type of ceramic filter machine as an example, according to known conditions and through calculation and analysis, we determined the air pressure and accumulator volume and chose the NXQA-16/10-L-A accumulator. By employing the TT-45 type of ceramic filter machine as an example, changing the internal structure of the distribution valve from round to waist, the backwash time was prolonged. With the use of the two kinds of methods, we demonstrated that the pressure fluctuation was reduced to be within 0.02 MPa, which satisfied the requirements for recoiling washing.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
EXTRACTOR: An extensible framework for identifying Aspect-Oriented refactoring opportunities Scenario simulation of Sino-Singapore Tianjin Eco-city development based on System Dynamics Face recognition based on classifier combinations Computer aided design and manufacture of high precision cam Design of wireless sensor networks for density of natural gas
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1