{"title":"交流应力下直流试验对交联聚乙烯绝缘寿命的影响","authors":"J. Parpal, C. Guddemi, N. Amyot, É. David","doi":"10.1109/ICPADM.1994.414021","DOIUrl":null,"url":null,"abstract":"DC testing is extensively used to verify the dielectric integrity of underground cables after installation, repair or maintenance. Although DC testing is very simple and inexpensive (compact test devices), there is some concern that it could affect the lifetime of polymeric insulation. The debate has been raging for many years but there are very few reported studies to help determine whether DC testing should be eliminated and replaced by low-frequency (0.1 Hz) or oscillating-wave tests.<<ETX>>","PeriodicalId":331058,"journal":{"name":"Proceedings of 1994 4th International Conference on Properties and Applications of Dielectric Materials (ICPADM)","volume":"115 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Influence of DC testing on XLPE insulation lifetime under AC stress\",\"authors\":\"J. Parpal, C. Guddemi, N. Amyot, É. David\",\"doi\":\"10.1109/ICPADM.1994.414021\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"DC testing is extensively used to verify the dielectric integrity of underground cables after installation, repair or maintenance. Although DC testing is very simple and inexpensive (compact test devices), there is some concern that it could affect the lifetime of polymeric insulation. The debate has been raging for many years but there are very few reported studies to help determine whether DC testing should be eliminated and replaced by low-frequency (0.1 Hz) or oscillating-wave tests.<<ETX>>\",\"PeriodicalId\":331058,\"journal\":{\"name\":\"Proceedings of 1994 4th International Conference on Properties and Applications of Dielectric Materials (ICPADM)\",\"volume\":\"115 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 1994 4th International Conference on Properties and Applications of Dielectric Materials (ICPADM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPADM.1994.414021\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1994 4th International Conference on Properties and Applications of Dielectric Materials (ICPADM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPADM.1994.414021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Influence of DC testing on XLPE insulation lifetime under AC stress
DC testing is extensively used to verify the dielectric integrity of underground cables after installation, repair or maintenance. Although DC testing is very simple and inexpensive (compact test devices), there is some concern that it could affect the lifetime of polymeric insulation. The debate has been raging for many years but there are very few reported studies to help determine whether DC testing should be eliminated and replaced by low-frequency (0.1 Hz) or oscillating-wave tests.<>