用于紧凑脉冲电源的叠置平行板固体介质布卢姆莱恩线

M. Domonkos, J. O'Loughlin, T. Tran, P. Turchi, Darwin Brown, C. W. Gregg, J. Parker, T. Montoya, K. Slenes
{"title":"用于紧凑脉冲电源的叠置平行板固体介质布卢姆莱恩线","authors":"M. Domonkos, J. O'Loughlin, T. Tran, P. Turchi, Darwin Brown, C. W. Gregg, J. Parker, T. Montoya, K. Slenes","doi":"10.1109/PPPS.2007.4345674","DOIUrl":null,"url":null,"abstract":"The stacked Blumlein line is a concept that has been touted as a highly compact pulsed power system because it combines the functions of energy storage, voltage scaling, and pulse shaping into a single sub-system. As a result, two single stage Blumlein lines have been fabricated and tested using a polymer-ceramic composite dielectric. Examination of the breakdown of the dielectric near the DC voltage specification led to the understanding of the degree of voltage reversal experienced by the lines. Voltage reversal is compounded in a stacked arrangement. The voltage reversal and transients induced by the switch jitter in a stacked configuration require significant derating of the dielectric strength. Consequently, the system must be operated much below the intrinsic dielectric energy density, compromising efforts to design a compact pulsed power system. This paper presents the conclusion that for derating below 0.72, as is likely necessary, a stacked Blumlein line will contain more dielectric than a comparable stacked transmission line.","PeriodicalId":275106,"journal":{"name":"2007 16th IEEE International Pulsed Power Conference","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Stacked, parallel-plate solid-dielectric Blumlein lines for compact pulsed power\",\"authors\":\"M. Domonkos, J. O'Loughlin, T. Tran, P. Turchi, Darwin Brown, C. W. Gregg, J. Parker, T. Montoya, K. Slenes\",\"doi\":\"10.1109/PPPS.2007.4345674\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The stacked Blumlein line is a concept that has been touted as a highly compact pulsed power system because it combines the functions of energy storage, voltage scaling, and pulse shaping into a single sub-system. As a result, two single stage Blumlein lines have been fabricated and tested using a polymer-ceramic composite dielectric. Examination of the breakdown of the dielectric near the DC voltage specification led to the understanding of the degree of voltage reversal experienced by the lines. Voltage reversal is compounded in a stacked arrangement. The voltage reversal and transients induced by the switch jitter in a stacked configuration require significant derating of the dielectric strength. Consequently, the system must be operated much below the intrinsic dielectric energy density, compromising efforts to design a compact pulsed power system. This paper presents the conclusion that for derating below 0.72, as is likely necessary, a stacked Blumlein line will contain more dielectric than a comparable stacked transmission line.\",\"PeriodicalId\":275106,\"journal\":{\"name\":\"2007 16th IEEE International Pulsed Power Conference\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-06-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 16th IEEE International Pulsed Power Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PPPS.2007.4345674\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 16th IEEE International Pulsed Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPPS.2007.4345674","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

堆叠Blumlein线是一种被吹捧为高度紧凑的脉冲电源系统的概念,因为它将能量存储、电压缩放和脉冲整形功能结合到一个子系统中。因此,使用聚合物-陶瓷复合电介质制备了两个单级Blumlein线并进行了测试。检查介电介质在直流电压规范附近的击穿情况,可以了解线路所经历的电压反转程度。电压反转是叠加在一起的。在堆叠结构中,由开关抖动引起的电压反转和瞬态需要显著的介电强度降额。因此,系统必须在远低于固有介电能量密度的情况下运行,从而降低了设计紧凑脉冲功率系统的努力。本文提出的结论是,当降额低于0.72时,很可能是必要的,堆叠的Blumlein线将比类似的堆叠传输线包含更多的介电。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Stacked, parallel-plate solid-dielectric Blumlein lines for compact pulsed power
The stacked Blumlein line is a concept that has been touted as a highly compact pulsed power system because it combines the functions of energy storage, voltage scaling, and pulse shaping into a single sub-system. As a result, two single stage Blumlein lines have been fabricated and tested using a polymer-ceramic composite dielectric. Examination of the breakdown of the dielectric near the DC voltage specification led to the understanding of the degree of voltage reversal experienced by the lines. Voltage reversal is compounded in a stacked arrangement. The voltage reversal and transients induced by the switch jitter in a stacked configuration require significant derating of the dielectric strength. Consequently, the system must be operated much below the intrinsic dielectric energy density, compromising efforts to design a compact pulsed power system. This paper presents the conclusion that for derating below 0.72, as is likely necessary, a stacked Blumlein line will contain more dielectric than a comparable stacked transmission line.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Dissipative instability under weak beam-plasma coupling Inductive heating of materials for the study of high-temperature mechanical properties. Application of a self-breakdown hydrogen spark gap switch on high power pulse modulator Discharge current and current of supershort avalanche E-beam at volume nanosecond discharge in non-uniform electric field Vertical dust particle chains - mass and charge measurements
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1