Thanh Long Nguyen, M. Lee, K. Hasegawa, Yun‐Jae Kim
{"title":"纵向距离对非对准双裂纹管破坏应力影响的数值研究","authors":"Thanh Long Nguyen, M. Lee, K. Hasegawa, Yun‐Jae Kim","doi":"10.1115/PVP2018-84838","DOIUrl":null,"url":null,"abstract":"In this study, the effect of longitudinal distance H between non-aligned twin cracks is investigated using finite element damage analysis. The FE damage analysis based on the stress-modified fracture strain model is used to calculate the failure stress of non-aligned twin cracked pipe. Parametric study on the axial distance H between non-aligned twin cracks with various crack depths and lengths were conducted and compared with predictions using the alignment rules and the net-section collapse load approach for single crack provided in ASME Code. It is shown that the trend of the predicted collapse bending stresses for the non-aligned twin cracked pipes using FE damage analysis are different from the ones using the alignment rule.","PeriodicalId":128383,"journal":{"name":"Volume 1A: Codes and Standards","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Numerical Study on Longitudinal Distance Effect on Failure Stress of Non-Aligned Twin Cracked Pipe\",\"authors\":\"Thanh Long Nguyen, M. Lee, K. Hasegawa, Yun‐Jae Kim\",\"doi\":\"10.1115/PVP2018-84838\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, the effect of longitudinal distance H between non-aligned twin cracks is investigated using finite element damage analysis. The FE damage analysis based on the stress-modified fracture strain model is used to calculate the failure stress of non-aligned twin cracked pipe. Parametric study on the axial distance H between non-aligned twin cracks with various crack depths and lengths were conducted and compared with predictions using the alignment rules and the net-section collapse load approach for single crack provided in ASME Code. It is shown that the trend of the predicted collapse bending stresses for the non-aligned twin cracked pipes using FE damage analysis are different from the ones using the alignment rule.\",\"PeriodicalId\":128383,\"journal\":{\"name\":\"Volume 1A: Codes and Standards\",\"volume\":\"76 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 1A: Codes and Standards\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/PVP2018-84838\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 1A: Codes and Standards","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/PVP2018-84838","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Numerical Study on Longitudinal Distance Effect on Failure Stress of Non-Aligned Twin Cracked Pipe
In this study, the effect of longitudinal distance H between non-aligned twin cracks is investigated using finite element damage analysis. The FE damage analysis based on the stress-modified fracture strain model is used to calculate the failure stress of non-aligned twin cracked pipe. Parametric study on the axial distance H between non-aligned twin cracks with various crack depths and lengths were conducted and compared with predictions using the alignment rules and the net-section collapse load approach for single crack provided in ASME Code. It is shown that the trend of the predicted collapse bending stresses for the non-aligned twin cracked pipes using FE damage analysis are different from the ones using the alignment rule.