高海拔地区室外绝缘子的选择研究

W. Shi, Z. Guan, L.M. Wang, J. Zhou
{"title":"高海拔地区室外绝缘子的选择研究","authors":"W. Shi, Z. Guan, L.M. Wang, J. Zhou","doi":"10.1109/CEIDP.2003.1254875","DOIUrl":null,"url":null,"abstract":"In recent years, large-scale development of China's western region has been vigorously promoted. As part of the development, several very high voltage transmission lines have been or are planning to be built in China's western region with a high altitude. The contamination flashover of insulators depends not only on the severity and type of contamination, but also on the altitude at which these insulators are situated. Reduced pressure or air density combined with light contamination at high altitudes decrease the flashover voltage. This paper analyzes the affects of low air pressure on the insulation characters of the transmission lines theoretically and experimentally, and a suggestion is given for the selection of outdoor insulator that will be used in the 110 kV AC power transmission line along Qinghai-Tibet railway.","PeriodicalId":306575,"journal":{"name":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"A study on the selection of outdoor insulators used in high altitude areas\",\"authors\":\"W. Shi, Z. Guan, L.M. Wang, J. Zhou\",\"doi\":\"10.1109/CEIDP.2003.1254875\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In recent years, large-scale development of China's western region has been vigorously promoted. As part of the development, several very high voltage transmission lines have been or are planning to be built in China's western region with a high altitude. The contamination flashover of insulators depends not only on the severity and type of contamination, but also on the altitude at which these insulators are situated. Reduced pressure or air density combined with light contamination at high altitudes decrease the flashover voltage. This paper analyzes the affects of low air pressure on the insulation characters of the transmission lines theoretically and experimentally, and a suggestion is given for the selection of outdoor insulator that will be used in the 110 kV AC power transmission line along Qinghai-Tibet railway.\",\"PeriodicalId\":306575,\"journal\":{\"name\":\"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2003.1254875\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2003.1254875","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

近年来,中国大力推进西部大开发。作为开发的一部分,中国西部高海拔地区已经或正在计划修建几条超高压输电线路。绝缘子的污闪不仅取决于污染的严重程度和类型,而且还取决于这些绝缘子所处的高度。在高海拔地区,压力或空气密度降低,再加上光污染,会降低闪络电压。本文从理论和实验两方面分析了低压对输电线路绝缘特性的影响,并对青藏铁路110kv交流输电线路室外绝缘子的选用提出了建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A study on the selection of outdoor insulators used in high altitude areas
In recent years, large-scale development of China's western region has been vigorously promoted. As part of the development, several very high voltage transmission lines have been or are planning to be built in China's western region with a high altitude. The contamination flashover of insulators depends not only on the severity and type of contamination, but also on the altitude at which these insulators are situated. Reduced pressure or air density combined with light contamination at high altitudes decrease the flashover voltage. This paper analyzes the affects of low air pressure on the insulation characters of the transmission lines theoretically and experimentally, and a suggestion is given for the selection of outdoor insulator that will be used in the 110 kV AC power transmission line along Qinghai-Tibet railway.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The effect of temperature and the mutual influence between two cavities of on the appearance of partial discharges in gaseous cavities contained in the insulator of high voltage Breakdown strength at the interface between epoxy resin and silicone rubber Surface change of polyamide nanocomposite caused by partial discharges Surface finish effects on partial discharge with embedded electrodes Roles of cumyl alcohol and crosslinked structure in homo-charge trapping in crosslinked polyethylene
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1