{"title":"两级单相高频链路逆变器的调制与控制","authors":"Keliang Zhou, Fei Peng, M. Cheng","doi":"10.1109/PEDG.2012.6254011","DOIUrl":null,"url":null,"abstract":"A two-stage high-frequency link inverter with active clamper, which has galvanic isolation, two-stage power conversion, bidirectional power flow, high efficiency, and high power density, is investigated in this paper. Modulation method and control strategy are developed for this inverter to achieve satisfactory system performance. Experiments are carried out to evaluate the proposed modulation and control strategy.","PeriodicalId":146438,"journal":{"name":"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Modulation and control of a two-stage single-phase high frequency link inverter\",\"authors\":\"Keliang Zhou, Fei Peng, M. Cheng\",\"doi\":\"10.1109/PEDG.2012.6254011\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A two-stage high-frequency link inverter with active clamper, which has galvanic isolation, two-stage power conversion, bidirectional power flow, high efficiency, and high power density, is investigated in this paper. Modulation method and control strategy are developed for this inverter to achieve satisfactory system performance. Experiments are carried out to evaluate the proposed modulation and control strategy.\",\"PeriodicalId\":146438,\"journal\":{\"name\":\"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDG.2012.6254011\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDG.2012.6254011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Modulation and control of a two-stage single-phase high frequency link inverter
A two-stage high-frequency link inverter with active clamper, which has galvanic isolation, two-stage power conversion, bidirectional power flow, high efficiency, and high power density, is investigated in this paper. Modulation method and control strategy are developed for this inverter to achieve satisfactory system performance. Experiments are carried out to evaluate the proposed modulation and control strategy.