基于灰狼优化技术的不对称故障去除及总谐波畸变分析

Sandeep Kaur
{"title":"基于灰狼优化技术的不对称故障去除及总谐波畸变分析","authors":"Sandeep Kaur","doi":"10.1109/ICIRCA51532.2021.9544728","DOIUrl":null,"url":null,"abstract":"In this Research paper the Author has obtained results through the use of MATLAB SIMULATION which shows that when a new optimization technique called Grey Wolf is applied on Distribution Static Compensator (D-STATCOM), it leads to further improved results for voltage sag and current swell for the three phase fault, double line to ground fault and single line to ground fault. To remove the Total Harmonic Distortion in Distribution System, a new optimization Technique called Grey Wolf Optimization (GWO) has been introduced. The results obtained after using GWO are very encouraging and it has further reduced voltage sag and current swell in the distribution system.","PeriodicalId":245244,"journal":{"name":"2021 Third International Conference on Inventive Research in Computing Applications (ICIRCA)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Removal of Unsymmetrical faults and Analysis of Total Harmonic Distortion by using Grey Wolf Optimization Technique\",\"authors\":\"Sandeep Kaur\",\"doi\":\"10.1109/ICIRCA51532.2021.9544728\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this Research paper the Author has obtained results through the use of MATLAB SIMULATION which shows that when a new optimization technique called Grey Wolf is applied on Distribution Static Compensator (D-STATCOM), it leads to further improved results for voltage sag and current swell for the three phase fault, double line to ground fault and single line to ground fault. To remove the Total Harmonic Distortion in Distribution System, a new optimization Technique called Grey Wolf Optimization (GWO) has been introduced. The results obtained after using GWO are very encouraging and it has further reduced voltage sag and current swell in the distribution system.\",\"PeriodicalId\":245244,\"journal\":{\"name\":\"2021 Third International Conference on Inventive Research in Computing Applications (ICIRCA)\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 Third International Conference on Inventive Research in Computing Applications (ICIRCA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIRCA51532.2021.9544728\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Third International Conference on Inventive Research in Computing Applications (ICIRCA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIRCA51532.2021.9544728","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文通过MATLAB仿真得到的结果表明,将灰狼优化技术应用于配电静态补偿器(D-STATCOM)后,对三相故障、双线对地故障和单线对地故障的电压暂降和电流膨胀效果进一步改善。为了消除配电系统的总谐波失真,提出了一种新的优化技术——灰狼优化。使用GWO后取得了令人鼓舞的效果,进一步降低了配电系统的电压凹陷和电流膨胀。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Removal of Unsymmetrical faults and Analysis of Total Harmonic Distortion by using Grey Wolf Optimization Technique
In this Research paper the Author has obtained results through the use of MATLAB SIMULATION which shows that when a new optimization technique called Grey Wolf is applied on Distribution Static Compensator (D-STATCOM), it leads to further improved results for voltage sag and current swell for the three phase fault, double line to ground fault and single line to ground fault. To remove the Total Harmonic Distortion in Distribution System, a new optimization Technique called Grey Wolf Optimization (GWO) has been introduced. The results obtained after using GWO are very encouraging and it has further reduced voltage sag and current swell in the distribution system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Morse Code Detector and Decoder using Eye Blinks Detection of Social and Newsworthy events using Tweet Analysis An Efficient Workflow Management Model for Fog Computing Application Analysis of Image Enhancement Method in Deep Learning Image Recognition Scene Virtual Learning Assistance for Students
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1