{"title":"不连续浆液渗透垫层混凝土(SIMCON)护套抗震加固","authors":"N. Krstulovic-Opara, J. LaFave, E. Dogan, C. Uang","doi":"10.14359/5715","DOIUrl":null,"url":null,"abstract":"Older reinforced concrete structures constructed in seismically active areas of the United States are usually non-ductile and are identified as hazardous. Extensive efforts have been devoted to the development of adequate retrofitting techniques for these buildings. This paper describes a research to develop a novel seismic retrofit technique, using recently developed high performance fiber reinforced concretes (HPFRC), to solve several common problems of nonseismically designed reinforced concrete frames.","PeriodicalId":148554,"journal":{"name":"SP-185: High-Performance Fiber Reinforced Concrete in Infrastructural Repair and Retrofit","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Seismic Retrofit with Discontinuous Slurry Infiltrated Mat Concrete (SIMCON) Jackets\",\"authors\":\"N. Krstulovic-Opara, J. LaFave, E. Dogan, C. Uang\",\"doi\":\"10.14359/5715\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Older reinforced concrete structures constructed in seismically active areas of the United States are usually non-ductile and are identified as hazardous. Extensive efforts have been devoted to the development of adequate retrofitting techniques for these buildings. This paper describes a research to develop a novel seismic retrofit technique, using recently developed high performance fiber reinforced concretes (HPFRC), to solve several common problems of nonseismically designed reinforced concrete frames.\",\"PeriodicalId\":148554,\"journal\":{\"name\":\"SP-185: High-Performance Fiber Reinforced Concrete in Infrastructural Repair and Retrofit\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SP-185: High-Performance Fiber Reinforced Concrete in Infrastructural Repair and Retrofit\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14359/5715\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SP-185: High-Performance Fiber Reinforced Concrete in Infrastructural Repair and Retrofit","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14359/5715","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Seismic Retrofit with Discontinuous Slurry Infiltrated Mat Concrete (SIMCON) Jackets
Older reinforced concrete structures constructed in seismically active areas of the United States are usually non-ductile and are identified as hazardous. Extensive efforts have been devoted to the development of adequate retrofitting techniques for these buildings. This paper describes a research to develop a novel seismic retrofit technique, using recently developed high performance fiber reinforced concretes (HPFRC), to solve several common problems of nonseismically designed reinforced concrete frames.