基于3级联h桥多电平逆变器和模糊逻辑的感应电机直接转矩控制

A. Mortezaei, N. Azli, N. Idris, S. Mahmoodi, N. M. Nordin
{"title":"基于3级联h桥多电平逆变器和模糊逻辑的感应电机直接转矩控制","authors":"A. Mortezaei, N. Azli, N. Idris, S. Mahmoodi, N. M. Nordin","doi":"10.1109/IAPEC.2011.5779862","DOIUrl":null,"url":null,"abstract":"This paper proposes the use of a 3-level Cascaded H-Bridge Multilevel Inverter (CHMI) topology which results in further torque ripple minimization compared to the 2-level inverter-based Direct Torque Control (DTC). This is due to the increase in the inverter switching voltage vectors that allows minimization of the torque error. This in turn can reduce the Total Harmonic Distortion (THD) of the output voltage and current as well. This paper also presents two different control methods in selecting the appropriate output voltage vector for reducing the torque and flux error to zero. The first is based on the conventional DTC scheme using a pair of hysteresis comparators and look-up table to select the output voltage vector for controlling the torque and flux. The second is based on a new fuzzy logic controller (FLC) with Sugeno as its inference method to select the output voltage vector by replacing the hysteresis comparators and look-up table in the conventional DTC scheme. The latter has solved the problem of variable switching frequency which is the main characteristic of the former. By using FLC DTC not only the flux ripples reduce significantly but also the THD of the phase current decreases since a more sinusoidal current waveform is achieved. The simulation results have proven that by using the 3-level CHMI, torque ripple reduction is obtained compared to the 2-level inverter-based DTC while fuzzy DTC shows reduction in the stator flux ripples and the THD of the phase current.","PeriodicalId":386166,"journal":{"name":"2011 IEEE Applied Power Electronics Colloquium (IAPEC)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Direct torque control of induction machines utilizing 3-level cascaded H-Bridge Multilevel Inverter and fuzzy logic\",\"authors\":\"A. Mortezaei, N. Azli, N. Idris, S. Mahmoodi, N. M. Nordin\",\"doi\":\"10.1109/IAPEC.2011.5779862\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes the use of a 3-level Cascaded H-Bridge Multilevel Inverter (CHMI) topology which results in further torque ripple minimization compared to the 2-level inverter-based Direct Torque Control (DTC). This is due to the increase in the inverter switching voltage vectors that allows minimization of the torque error. This in turn can reduce the Total Harmonic Distortion (THD) of the output voltage and current as well. This paper also presents two different control methods in selecting the appropriate output voltage vector for reducing the torque and flux error to zero. The first is based on the conventional DTC scheme using a pair of hysteresis comparators and look-up table to select the output voltage vector for controlling the torque and flux. The second is based on a new fuzzy logic controller (FLC) with Sugeno as its inference method to select the output voltage vector by replacing the hysteresis comparators and look-up table in the conventional DTC scheme. The latter has solved the problem of variable switching frequency which is the main characteristic of the former. By using FLC DTC not only the flux ripples reduce significantly but also the THD of the phase current decreases since a more sinusoidal current waveform is achieved. The simulation results have proven that by using the 3-level CHMI, torque ripple reduction is obtained compared to the 2-level inverter-based DTC while fuzzy DTC shows reduction in the stator flux ripples and the THD of the phase current.\",\"PeriodicalId\":386166,\"journal\":{\"name\":\"2011 IEEE Applied Power Electronics Colloquium (IAPEC)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-04-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE Applied Power Electronics Colloquium (IAPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAPEC.2011.5779862\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE Applied Power Electronics Colloquium (IAPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAPEC.2011.5779862","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

本文提出使用3电平级联h桥多电平逆变器(CHMI)拓扑,与基于2电平逆变器的直接转矩控制(DTC)相比,该拓扑可进一步减少转矩脉动。这是由于增加了逆变器开关电压矢量,使转矩误差最小化。这反过来又可以减少输出电压和电流的总谐波失真(THD)。本文还介绍了两种不同的控制方法,以选择合适的输出电压矢量,使转矩和磁链误差降至零。第一个是在传统的直接转矩控制方案的基础上,利用一对磁滞比较器和查找表选择输出电压矢量来控制转矩和磁链。第二种是基于一种新的模糊逻辑控制器(FLC),以Sugeno作为其推理方法,通过替换传统直接转矩控制方案中的滞回比较器和查找表来选择输出电压矢量。后者解决了前者的主要特点——开关频率可变的问题。采用FLC直接转矩控制不仅使磁链波纹明显减小,而且使相电流的THD减小,因为电流波形更加正弦化。仿真结果表明,与基于2级逆变器的直接转矩控制相比,采用3级CHMI控制可以减小转矩脉动,而模糊直接转矩控制则可以减小定子磁链脉动和相电流的THD。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Direct torque control of induction machines utilizing 3-level cascaded H-Bridge Multilevel Inverter and fuzzy logic
This paper proposes the use of a 3-level Cascaded H-Bridge Multilevel Inverter (CHMI) topology which results in further torque ripple minimization compared to the 2-level inverter-based Direct Torque Control (DTC). This is due to the increase in the inverter switching voltage vectors that allows minimization of the torque error. This in turn can reduce the Total Harmonic Distortion (THD) of the output voltage and current as well. This paper also presents two different control methods in selecting the appropriate output voltage vector for reducing the torque and flux error to zero. The first is based on the conventional DTC scheme using a pair of hysteresis comparators and look-up table to select the output voltage vector for controlling the torque and flux. The second is based on a new fuzzy logic controller (FLC) with Sugeno as its inference method to select the output voltage vector by replacing the hysteresis comparators and look-up table in the conventional DTC scheme. The latter has solved the problem of variable switching frequency which is the main characteristic of the former. By using FLC DTC not only the flux ripples reduce significantly but also the THD of the phase current decreases since a more sinusoidal current waveform is achieved. The simulation results have proven that by using the 3-level CHMI, torque ripple reduction is obtained compared to the 2-level inverter-based DTC while fuzzy DTC shows reduction in the stator flux ripples and the THD of the phase current.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Copyright page Parallel configuration in energy management control for the fuel cell-battery-ultracapacitor hybrid vehicles Automated test set-up for reverse recovery characterization of ultrafast diodes Design of a current mode PI controller for a single-phase PWM inverter Space Vector based Spread Spectrum Modulation scheme for three-level inverters
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1