[献血者SGPT的诊断]。

R Grunenberg, J Krüger
{"title":"[献血者SGPT的诊断]。","authors":"R Grunenberg,&nbsp;J Krüger","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Presampling determination for hemoglobin has been pursued for a long time, but now it is becoming possible to examine further parameters such as SGPT (ALT). The SGPT predonation testing is best performed with the Reflotron system (Fa. Boehringer Mannheim) since whole blood samples drawn into capillary tube can be used. Between 1985 and 1988 1.35-1.75% of an average of 22,000 whole blood donations were found to have SGPT levels above the accepted cutoff (> 30 IU/l, 25 degrees C). The cost per test using the UV kinetics and the overall expenses of unusable collections were compared with the cost of SGPT predonation testing. An average of DM 20,000.-per year has been saved. Therefore prescreening of SGPT in blood banking is a highly cost-effective approach.</p>","PeriodicalId":77034,"journal":{"name":"Beitrage zur Infusionstherapie = Contributions to infusion therapy","volume":"30 ","pages":"73-4"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Diagnosis of the presence of SGPT in blood donors].\",\"authors\":\"R Grunenberg,&nbsp;J Krüger\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Presampling determination for hemoglobin has been pursued for a long time, but now it is becoming possible to examine further parameters such as SGPT (ALT). The SGPT predonation testing is best performed with the Reflotron system (Fa. Boehringer Mannheim) since whole blood samples drawn into capillary tube can be used. Between 1985 and 1988 1.35-1.75% of an average of 22,000 whole blood donations were found to have SGPT levels above the accepted cutoff (> 30 IU/l, 25 degrees C). The cost per test using the UV kinetics and the overall expenses of unusable collections were compared with the cost of SGPT predonation testing. An average of DM 20,000.-per year has been saved. Therefore prescreening of SGPT in blood banking is a highly cost-effective approach.</p>\",\"PeriodicalId\":77034,\"journal\":{\"name\":\"Beitrage zur Infusionstherapie = Contributions to infusion therapy\",\"volume\":\"30 \",\"pages\":\"73-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Beitrage zur Infusionstherapie = Contributions to infusion therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Beitrage zur Infusionstherapie = Contributions to infusion therapy","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对血红蛋白的前采样测定已经进行了很长时间,但现在可以检查进一步的参数,如SGPT (ALT)。捐献前SGPT检测最好使用Reflotron系统(Fa)。Boehringer Mannheim),因为整个血液样本抽取到毛细管中可以使用。在1985年至1988年期间,平均22,000全血捐献中有1.35-1.75%的人被发现SGPT水平高于可接受的截止值(> 30 IU/l, 25℃)。使用紫外动力学的每次测试成本和不可用收集的总费用与捐献前SGPT测试的成本进行了比较。平均为20,000马克。-每年已节省。因此,在血库中进行SGPT的预筛查是一种成本效益很高的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Diagnosis of the presence of SGPT in blood donors].

Presampling determination for hemoglobin has been pursued for a long time, but now it is becoming possible to examine further parameters such as SGPT (ALT). The SGPT predonation testing is best performed with the Reflotron system (Fa. Boehringer Mannheim) since whole blood samples drawn into capillary tube can be used. Between 1985 and 1988 1.35-1.75% of an average of 22,000 whole blood donations were found to have SGPT levels above the accepted cutoff (> 30 IU/l, 25 degrees C). The cost per test using the UV kinetics and the overall expenses of unusable collections were compared with the cost of SGPT predonation testing. An average of DM 20,000.-per year has been saved. Therefore prescreening of SGPT in blood banking is a highly cost-effective approach.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Magnesium Infusion Therapy Opioid Infusion Therapy Dexmedetomidine Infusion Therapy Clonidine Infusion Therapy Lidocaine Infusion Therapy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1