{"title":"直接法分析交直流混合电力系统暂态稳定性","authors":"Xing Chen, Yin Xu, Jinghan He","doi":"10.1109/CIEEC.2018.8745866","DOIUrl":null,"url":null,"abstract":"Large-scale AC-DC hybrid power systems have become a basic pattern for power transmission in China. Currently, time-domain simulation is widely used for transient stability analysis, which has the disadvantages of high computational burdens and lack of system stability margin information. An alternative method for transient stability analysis is the direct method, which assesses transient stability from the energy point of view. Direct method requires much less computation efforts. In addition, the stability margin of the system can be obtained. Due to the challenges in system modelling, energy function construction, and determination of critical energy value, it is challenging to apply direct method for transient stability analysis of AC-DC hybrid power systems. This paper is a step in exploring the application of direct method in AC-DC hybrid power systems.","PeriodicalId":329285,"journal":{"name":"2018 IEEE 2nd International Electrical and Energy Conference (CIEEC)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Transient Stability Analysis of AC-DC Hybrid Power Systems Using Direct Method\",\"authors\":\"Xing Chen, Yin Xu, Jinghan He\",\"doi\":\"10.1109/CIEEC.2018.8745866\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Large-scale AC-DC hybrid power systems have become a basic pattern for power transmission in China. Currently, time-domain simulation is widely used for transient stability analysis, which has the disadvantages of high computational burdens and lack of system stability margin information. An alternative method for transient stability analysis is the direct method, which assesses transient stability from the energy point of view. Direct method requires much less computation efforts. In addition, the stability margin of the system can be obtained. Due to the challenges in system modelling, energy function construction, and determination of critical energy value, it is challenging to apply direct method for transient stability analysis of AC-DC hybrid power systems. This paper is a step in exploring the application of direct method in AC-DC hybrid power systems.\",\"PeriodicalId\":329285,\"journal\":{\"name\":\"2018 IEEE 2nd International Electrical and Energy Conference (CIEEC)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE 2nd International Electrical and Energy Conference (CIEEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIEEC.2018.8745866\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE 2nd International Electrical and Energy Conference (CIEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIEEC.2018.8745866","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Transient Stability Analysis of AC-DC Hybrid Power Systems Using Direct Method
Large-scale AC-DC hybrid power systems have become a basic pattern for power transmission in China. Currently, time-domain simulation is widely used for transient stability analysis, which has the disadvantages of high computational burdens and lack of system stability margin information. An alternative method for transient stability analysis is the direct method, which assesses transient stability from the energy point of view. Direct method requires much less computation efforts. In addition, the stability margin of the system can be obtained. Due to the challenges in system modelling, energy function construction, and determination of critical energy value, it is challenging to apply direct method for transient stability analysis of AC-DC hybrid power systems. This paper is a step in exploring the application of direct method in AC-DC hybrid power systems.