Sangyeong Jeong, Jingook Kim, Young-Hwan Baek, Wonwoo Lee, Gwigeun Park
{"title":"用于减少家用电器传导辐射的电缆和机箱之间的终端接地滤波器","authors":"Sangyeong Jeong, Jingook Kim, Young-Hwan Baek, Wonwoo Lee, Gwigeun Park","doi":"10.1109/EMCSI.2018.8495422","DOIUrl":null,"url":null,"abstract":"A CM noise reduction method by adding a terminal ground filter between the cable ground and chassis is proposed. The noise reduction performance of the terminal ground filter is estimated with a simplified circuit model. The proposed filter is implemented in a small PCB, and applied to a 3.3kW power system of an air conditioner. The reduction of the CM CE noises by applying the terminal ground filter is experimentally validated.","PeriodicalId":120342,"journal":{"name":"2018 IEEE Symposium on Electromagnetic Compatibility, Signal Integrity and Power Integrity (EMC, SI & PI)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A Terminal Ground Filter between Cable and Chassis for Reduction of Conducted Emissions at a Home Appliance\",\"authors\":\"Sangyeong Jeong, Jingook Kim, Young-Hwan Baek, Wonwoo Lee, Gwigeun Park\",\"doi\":\"10.1109/EMCSI.2018.8495422\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A CM noise reduction method by adding a terminal ground filter between the cable ground and chassis is proposed. The noise reduction performance of the terminal ground filter is estimated with a simplified circuit model. The proposed filter is implemented in a small PCB, and applied to a 3.3kW power system of an air conditioner. The reduction of the CM CE noises by applying the terminal ground filter is experimentally validated.\",\"PeriodicalId\":120342,\"journal\":{\"name\":\"2018 IEEE Symposium on Electromagnetic Compatibility, Signal Integrity and Power Integrity (EMC, SI & PI)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Symposium on Electromagnetic Compatibility, Signal Integrity and Power Integrity (EMC, SI & PI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMCSI.2018.8495422\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Symposium on Electromagnetic Compatibility, Signal Integrity and Power Integrity (EMC, SI & PI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCSI.2018.8495422","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Terminal Ground Filter between Cable and Chassis for Reduction of Conducted Emissions at a Home Appliance
A CM noise reduction method by adding a terminal ground filter between the cable ground and chassis is proposed. The noise reduction performance of the terminal ground filter is estimated with a simplified circuit model. The proposed filter is implemented in a small PCB, and applied to a 3.3kW power system of an air conditioner. The reduction of the CM CE noises by applying the terminal ground filter is experimentally validated.