配电变压器防雷绕组模型

C. de Salles, M.L.B. Martinez
{"title":"配电变压器防雷绕组模型","authors":"C. de Salles, M.L.B. Martinez","doi":"10.1109/PCT.2007.4538633","DOIUrl":null,"url":null,"abstract":"This paper presents a mathematical model for distribution transformers winding to simulate its lightning impulse behavior. The aim is to investigate the real source of some signals present in the current wave of lightning impulse test. These signals are generally attached to the testing system and not to the testing transformer. This kind of interpretation can consider approved a failed transformer. The procedure takes into account the comparison between lightning impulse tests on actual transformers and their simulation results. The main contribution of this paper regarding previous publications [1]-[2] is concerning the current wave of chopped impulses. The idea is to use the chopped waves to confirm the existence of small failures on tested transformers that present some of noises in the current wave of full impulses.","PeriodicalId":356805,"journal":{"name":"2007 IEEE Lausanne Power Tech","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Model of Distribution Transformers Winding for Lightning\",\"authors\":\"C. de Salles, M.L.B. Martinez\",\"doi\":\"10.1109/PCT.2007.4538633\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a mathematical model for distribution transformers winding to simulate its lightning impulse behavior. The aim is to investigate the real source of some signals present in the current wave of lightning impulse test. These signals are generally attached to the testing system and not to the testing transformer. This kind of interpretation can consider approved a failed transformer. The procedure takes into account the comparison between lightning impulse tests on actual transformers and their simulation results. The main contribution of this paper regarding previous publications [1]-[2] is concerning the current wave of chopped impulses. The idea is to use the chopped waves to confirm the existence of small failures on tested transformers that present some of noises in the current wave of full impulses.\",\"PeriodicalId\":356805,\"journal\":{\"name\":\"2007 IEEE Lausanne Power Tech\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Lausanne Power Tech\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCT.2007.4538633\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Lausanne Power Tech","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCT.2007.4538633","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文建立了配电变压器绕组的数学模型来模拟其雷电冲击行为。目的是研究雷电冲击试验中电流波中某些信号的真实来源。这些信号通常附在测试系统上,而不是附在测试变压器上。这种解释可以考虑批准一个故障的变压器。该方法考虑了实际变压器雷电冲击试验与模拟结果的比较。本文对先前出版物[1]-[2]的主要贡献是关于斩波脉冲的电流波。这个想法是使用斩波来确认在测试变压器上存在的小故障,这些故障在全脉冲的电流波中呈现出一些噪声。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Model of Distribution Transformers Winding for Lightning
This paper presents a mathematical model for distribution transformers winding to simulate its lightning impulse behavior. The aim is to investigate the real source of some signals present in the current wave of lightning impulse test. These signals are generally attached to the testing system and not to the testing transformer. This kind of interpretation can consider approved a failed transformer. The procedure takes into account the comparison between lightning impulse tests on actual transformers and their simulation results. The main contribution of this paper regarding previous publications [1]-[2] is concerning the current wave of chopped impulses. The idea is to use the chopped waves to confirm the existence of small failures on tested transformers that present some of noises in the current wave of full impulses.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Northeast Asia Power Interconnection Routs and Representative Studies in South Korea PSO-based Hybrid Generating System Design Incorporating Reliability Evaluation and Generation/Load Forecasting Actual Problems Of The Distribution Cable Networks In Germany - Ageing And Structural Impact On The Reliability Study on Power Quality Control in Multiple Renewable Energy Hybrid MicroGrid System Configuration of a Large Scale Analog Emulator for Power System Analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1