{"title":"高氯酸盐离子光学传感器的研制","authors":"N. B. Messaoud, C. Dridi, M. N. Abbas","doi":"10.1109/DTS55284.2022.9809846","DOIUrl":null,"url":null,"abstract":"An optical sensor for perchlorate anions (CIO<inf>4</inf>-) comprising a structure of Cobalt phthalocyanine derivative (Co(II)Pc-PAA) modified glass electrode has been developed. The immobilization of Co(II)Pc-PAA membrane was confirmed by contact angle measurements. The response was determined by the increase in the absorbance signal as a function of exposure to buffer solutions containing different concentrations of CIO<inf>4</inf>- anions. The optical sensor showed a linear response to CI04- from 10<sup>–10</sup>M to 10<sup>–2</sup> M, with a limit of detection of 4.81 Χ10<sup>−10</sup>M, one of the lowest achieved up until now. The proposed sensor has demonstrated a good specificity to CIO<inf>4</inf>- when compared to common interferents anions such as CI<sup>−</sup>and NO<inf>3</inf>-. To the best of our knowledge, this is the first optode system for the detection of CIO<inf>4</inf>-, which provides a promising sensor for the specific and sensitive determination of CIO<inf>4</inf>- in environmental water samples.","PeriodicalId":290904,"journal":{"name":"2022 IEEE International Conference on Design & Test of Integrated Micro & Nano-Systems (DTS)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of optical sensor for determination of perchlorate ions\",\"authors\":\"N. B. Messaoud, C. Dridi, M. N. Abbas\",\"doi\":\"10.1109/DTS55284.2022.9809846\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An optical sensor for perchlorate anions (CIO<inf>4</inf>-) comprising a structure of Cobalt phthalocyanine derivative (Co(II)Pc-PAA) modified glass electrode has been developed. The immobilization of Co(II)Pc-PAA membrane was confirmed by contact angle measurements. The response was determined by the increase in the absorbance signal as a function of exposure to buffer solutions containing different concentrations of CIO<inf>4</inf>- anions. The optical sensor showed a linear response to CI04- from 10<sup>–10</sup>M to 10<sup>–2</sup> M, with a limit of detection of 4.81 Χ10<sup>−10</sup>M, one of the lowest achieved up until now. The proposed sensor has demonstrated a good specificity to CIO<inf>4</inf>- when compared to common interferents anions such as CI<sup>−</sup>and NO<inf>3</inf>-. To the best of our knowledge, this is the first optode system for the detection of CIO<inf>4</inf>-, which provides a promising sensor for the specific and sensitive determination of CIO<inf>4</inf>- in environmental water samples.\",\"PeriodicalId\":290904,\"journal\":{\"name\":\"2022 IEEE International Conference on Design & Test of Integrated Micro & Nano-Systems (DTS)\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE International Conference on Design & Test of Integrated Micro & Nano-Systems (DTS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DTS55284.2022.9809846\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Conference on Design & Test of Integrated Micro & Nano-Systems (DTS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DTS55284.2022.9809846","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of optical sensor for determination of perchlorate ions
An optical sensor for perchlorate anions (CIO4-) comprising a structure of Cobalt phthalocyanine derivative (Co(II)Pc-PAA) modified glass electrode has been developed. The immobilization of Co(II)Pc-PAA membrane was confirmed by contact angle measurements. The response was determined by the increase in the absorbance signal as a function of exposure to buffer solutions containing different concentrations of CIO4- anions. The optical sensor showed a linear response to CI04- from 10–10M to 10–2 M, with a limit of detection of 4.81 Χ10−10M, one of the lowest achieved up until now. The proposed sensor has demonstrated a good specificity to CIO4- when compared to common interferents anions such as CI−and NO3-. To the best of our knowledge, this is the first optode system for the detection of CIO4-, which provides a promising sensor for the specific and sensitive determination of CIO4- in environmental water samples.